scholarly journals Exergy, Economic and Environmental Analyses of Gas Turbine Inlet Air Cooling with a Heat Pump Using a Novel System Configuration

2015 ◽  
Vol 7 (10) ◽  
pp. 14259-14286 ◽  
Author(s):  
Mohammad Yazdi ◽  
Mehdi Aliehyaei ◽  
Marc Rosen
2007 ◽  
Vol 31 (13) ◽  
pp. 1292-1306 ◽  
Author(s):  
Galal M. Zaki ◽  
Rahim K. Jassim ◽  
Majed M. Alhazmy

Author(s):  
John Confurius

The profits that can be gained by use of inlet air cooling on gas turbines has been recognised for quite some time now and the systems installed throughout the world have shown the users in the gas turbine field that cooling indeed can be used to boost power at times when the ambient temperature reaches or exceeds the ISO rating temperature of the gas turbine. Drawback however being that the initial investment asked of the gas turbine user is rather large thus only justifying a cooling system in regions where the outdoor temperatures exceed the ISO rating time and again due to the climate in that region. Lately gas turbine users in colder climates have become interested in power augmentation during their short summer, however there is no justification for an investment like necessary when installing one of the presently available systems on the market. As the question reached us from more and more of our clients it stimulated us to go out and search for a low-investment solution to this problem. This resulted in the world’s first low pressure gas turbine inlet cooling system.


Author(s):  
A Nordin ◽  
D A Salim ◽  
M A Othoman ◽  
S N Omar Kamal ◽  
Danny Tam ◽  
...  

2020 ◽  
pp. 47-52
Author(s):  
Андрій Миколайович Радченко ◽  
Микола Іванович Радченко ◽  
Богдан Сергійович Портной ◽  
Сергій Анатолійович Кантор ◽  
Олександр Ігорович Прядко

The processes of the gas turbine inlet air cooling by exhaust heat conversion chillers, which utilizing the gas turbine exhaust gas heat, converting it into cold were analyzed. The use of two-stage air cooling has been investigated: to a temperature of 15°C – in an absorption lithium-bromide chiller and below to a temperature of 10°C – in an ejector chiller as stages of a two-stage absorption-ejector chiller. To simulate air cooling processes, the program "Guentner Product Calculator", one of the leading manufacturers of heat exchangers "Guentner", was used. The possibility of using the accumulated excess refrigeration capacity of a combined absorption-ejector chiller, which is formed at reduced current heat loads on air coolers at the gas turbine inlet, to cover the refrigeration capacity deficit arising at increased heat loads due to high ambient air temperatures has been investigated. The refrigeration capacity required to the gas turbine inlet air cooling was compared to an excess refrigeration capacity which excess of the current heat load. The considered air cooling system provides pre-cooling of air at the gas turbine inlet by using the excess refrigeration capacity of the absorption-ejector chiller, accumulated in the cold accumulator, to provide the required refrigeration capacity of the air pre-cooling booster stage. The simulation results proved the expediency of the gas turbine inlet air cooling using the accumulated excess refrigeration capacity of the combined absorption-ejector chiller. The proposed solution reduces by about 50% the design refrigeration capacity and, accordingly, the cost of the installed absorption lithium-bromide chiller, which acts as a high-temperature stage for cooling the ambient air at the gas turbine inlet.


Author(s):  
Andrii Radchenko ◽  
Lukasz Bohdal ◽  
Yang Zongming ◽  
Bohdan Portnoi ◽  
Veniamin Tkachenko

2015 ◽  
Vol 80 ◽  
pp. 168-177 ◽  
Author(s):  
Mirko Morini ◽  
Michele Pinelli ◽  
Pier Ruggero Spina ◽  
Anna Vaccari ◽  
Mauro Venturini

2020 ◽  
Author(s):  
A. Radchenko ◽  
N. Radchenko ◽  
A. Tsoy ◽  
B. Portnoi ◽  
S. Kantor

2017 ◽  
Author(s):  
Waleed El-Damaty ◽  
Mohamed Gadalla

With the current increase in electricity consumption and energy demand, most of the research focus is shifted towards the means of increasing the power plants efficiency in order to produce more electricity by using as less fuel as possible. Gas turbine power plants specifically have been under the study in the recent years due to its feasibility, low capital cost, simple design, compact size and higher efficiency compared to steam turbine power plants. There are a lot of operating conditions that affect the performance of the gas turbine which includes the inlet air climatic conditions, mass flow rate and the turbine inlet temperature. Many improvements and enhancements became applicable through the advancement in the material and cooling technologies. Cooling techniques could be used to cool the inlet air entering the compressor by utilizing evaporative coolers and mechanical chillers, and to cool the turbine blades in order to avoid a decline in the life of turbine blades due to unwanted exposure to thermal stresses and oxidation. Internal convection cooling, film cooling and transpiration cooling are the three main techniques that can be used in the process of turbine blades cooling. The main objective of this proposal is to improve the durability and performance of gas turbine power plants by proposing the usage of integrated system of solid desiccant with Maisotsenko cooler in the turbine blade cooling and inlet air cooling processes. Four configurations were presented and the results were an increase in the efficiency of the gas turbine cycle for all the cases specially the two stage Maisotsenko desiccant cooling system where the efficiency increased from 33.33% to 34.17% as well as maintaining the turbine inlet temperature at a desired level of 1500°K.


Sign in / Sign up

Export Citation Format

Share Document