scholarly journals The Impact of Extreme Weather Events on Bacterial Communities and Opportunistic Pathogens in a Drinking Water Treatment Plant

Water ◽  
2021 ◽  
Vol 14 (1) ◽  
pp. 54
Author(s):  
Wei Tang ◽  
Yunsi Liu ◽  
Qiuyan Li ◽  
Ling Chen ◽  
Qi Li ◽  
...  

Drinking water treatment processes are highly effective at improving water quality, but pathogens can still persist in treated water, especially after extreme weather events. To identify how extreme weather events affected bacterial populations in source and treated water, water samples were collected from the Yangtze River Delta area and a local full-scale drinking water treatment plant. Bacterial community structure and the occurrence of pathogens were investigated in samples using 16S rRNA sequencing and qPCR techniques. In this study, the results show that intense rainfall can significantly increase levels of bacteria and opportunistic pathogens in river and drinking water treatment processes (p < 0.05); in particular, the relative abundance of Cyanobacteria increased after a super typhoon event (p < 0.05). The biological activated carbon (BAC) tank was identified as a potential pathogen reservoir and was responsible for 52 ± 6% of the bacteria released downstream, according to Bayesian-based SourceTracker analysis. Our results provide an insight into the challenges faced by maintaining finished water quality under changing weather conditions.

2009 ◽  
Vol 60 (3) ◽  
pp. 709-715 ◽  
Author(s):  
Kim van Schagen ◽  
Luuk Rietveld ◽  
Alex Veersma ◽  
Robert Babuška

Owing to the nature of the treatment processes, monitoring the processes based on individual online measurements is difficult or even impossible. However, the measurements (online and laboratory) can be combined with a priori process knowledge, using mathematical models, to objectively monitor the treatment processes and measurement devices. The pH measurement is a commonly used measurement at different stages in the drinking water treatment plant, although it is a unreliable instrument, requiring significant maintenance. It is shown that, using a grey-box model, it is possible to assess the measurement devices effectively, even if detailed information of the specific processes is unknown.


Water ◽  
2019 ◽  
Vol 11 (9) ◽  
pp. 1821
Author(s):  
Sandhya Rao Poleneni ◽  
Enos Inniss ◽  
Honglan Shi ◽  
John Yang ◽  
Bin Hua ◽  
...  

Inefficient removal of total organic carbon (TOC) leads to the formation of carcinogenic disinfection by-products (DBPs) when a disinfectant is added. This study is performed in an effort to develop a simple, non-invasive, and cost-effective technology that will effectively lower organic precursors by having water utilities reuse their treatment residual solids. Jar tests are used to simulate drinking water treatment processes with coagulants—aluminum sulfate (alum), poly-aluminum chloride (PACl), and ferric chloride and their residual solids. Ten coagulant-to-residual (C/R) ratios are tested with water from the Missouri River at Coopers Landing in Columbia, MO versus alluvial ground waters. This treatment results in heavier floc formation and leads to improved sedimentation of organics and additional removal of aluminum and iron. An average of 21%, 28%, and 33% additional TOC removal can be achieved with C/R ratios <1 with alum, PACl, and ferric chloride, respectively.


2017 ◽  
Vol 18 (4) ◽  
pp. 1261-1269
Author(s):  
Zhiling Wu ◽  
Hongbin Chen

Abstract Invertebrate removal by traditional biological activated carbon (tra-BAC) and pre-BAC treatment processes was investigated in a full-scale water treatment plant. The results showed that invertebrate reproduction occurred in both BAC filters, but the invertebrate abundance in the finished water processed by tra-BAC was about 15 times greater than that processed using the pre-BAC process. In the pre-BAC process, the sand filter was placed after the BAC filter, and sand filtration removed most of the invertebrates, with an average removal efficiency of 91.1%. However, the pre-BAC filter, which was positioned behind the sedimentation tank, needed to be backwashed more frequently than the tra-BAC filter because of the high turbidity of the inlet water. The frequent backwashing reduced the biomass on the activated carbon and decreased the invertebrate reproductive rate. The results of this study are helpful for evaluating the pre-BAC treatment process in drinking water treatment plants.


2016 ◽  
Vol 16 (4) ◽  
pp. 922-930 ◽  
Author(s):  
L. Richard ◽  
E. Mayr ◽  
M. Zunabovic ◽  
R. Allabashi ◽  
R. Perfler

The implementation and evaluation of biological nitrification as a possible treatment option for the small-scale drinking water supply of a rural Upper Austrian community was investigated. The drinking water supply of this community (average system input volume: 20 m3/d) is based on the use of deep anaerobic groundwater with a high ammonium content of geogenic origin (up to 5 mg/l) which must be treated to prevent the formation of nitrites in the drinking water supply system. This paper describes the implementation and operation of biological nitrification despite several constraints including space availability, location and financial and manpower resources. A pilot drinking water treatment plant, including biological nitrification implemented in sand filters, was designed and constructed for a maximum treatment capacity of 1.2 m3/h. Online monitoring of selected physicochemical parameters has provided continuous treatment performance data. Treatment performance of the plant was evaluated under standard operation as well as in the case of selected malfunction events.


2017 ◽  
Vol 29 (12) ◽  
pp. 2665-2670
Author(s):  
Soleha Mohamat Yusuff ◽  
K.K. Ong ◽  
W.M.Z. Wan Yunus ◽  
A. Fitrianto ◽  
M. Ahmad ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document