Faculty Opinions recommendation of Development of a Chip/Chip/SRM platform using digital chip isoelectric focusing and LC-Chip mass spectrometry for enrichment and quantitation of low abundance protein biomarkers in human plasma.

Author(s):  
Jin-Xiong She ◽  
Wenbo Zhi
2019 ◽  
Vol 15 (7) ◽  
pp. 710-715
Author(s):  
S.T. Narenderan ◽  
Basuvan Babu ◽  
T. Gokul ◽  
Subramania Nainar Meyyanathan

Objective: The aim of the present work is to achieve a novel highly sensitive chromatographic method for the simultaneous determination of hepatitis C agents, sofosbuvir and velpatasvir from human plasma using ritonavir as an internal standard. Methods: Chromatographic separation was achieved using Hypersil C18 column (50mm x 4.6mm, 3μm) with an isocratic elution mode using the mobile phase composition 10 mM ammonium formate buffer (pH 5.0): acetonitrile (20:80 v/v) pumped at a flow rate of 0.5 ml/min. The detection was carried out by tandem mass spectrometry using Multiple Reaction Monitoring (MRM) positive Electrospray Ionization (ESI) with proton adducts at m/z 530.10 > 243.10, 883.40 > 114.0 and 721.25 > 197.0. Results: The method validated as per USFDA guidelines with respect to linearity, accuracy, and precision was found to be acceptable over the concentration range of 0.2–2000 ng/ml and 5-2000 ng/ml for sofosbuvir and velpatasvir respectively and the method was found to be highly sensitive and selective. Conclusion: The developed tandem mass spectrometric method is robust and can be applied for the monitoring of plasma levels of the analyzed drug in preclinical and clinical pharmacokinetic studies.


2018 ◽  
Vol 15 (1) ◽  
pp. 17-23
Author(s):  
Vulli Srinandan ◽  
Krishnaveni Nagappan ◽  
Sonam Patel ◽  
Karthik Yamjala ◽  
Gowramma Byran ◽  
...  

Background: Pantoprazole (PTZ) and Levosulpiride (LS) were proven as effective agents for the treatment of Gastro-Esophageal Reflux Disease (GERD). It is a complex motor disorder that results in regurgitation of the gastric contents into the lower esophagus with consequent symptoms such as heart burn, retrosternal pain, dysphagia and belching. Methods: A rapid, sensitive, selective and specific liquid chromatography- electro spray ionization tandem mass spectrometry (LC-MS/MS) method was developed for the simultaneous quantification of Pantoprazole (PTZ) and Levosulpiride (LS) in spiked Human Plasma. The method utilized SPE as sample preparation technique and the analysis was carried out on a HPLC system utilizing electro spray ionization as interface and triple quadrupole mass analyzer for quantification in MRM possitive mode. Iloperidone was used as internal standard (IS). Chromatographic separation was performed on a Phenomenex C-18 Column (4.6 mm x 50 mm, 5µ) with an isocratic elution mode utilizing a mobile phase composition of Solution containing a mixture of 70 volumes of acetonitrile: 30 volumes of methanol and 10mM ammonium formate (pH 4.0) at the ratio of 80:20 % v/v. The flow rate was maintained at 0.3 mL/min. Results: PTZ, LS and IS were detected and quantified with proton adducts at m/z 383.37→200.00, m/z 341.42→112.15 and 426.48→261.00 respectively. The linearity and range was established by fortifying blank plasma samples in the concentration range of 3.5-2000 ng/mL for PTZ and 3.0-2400 ng/mL for LS. The correlation coefficient (r2) was found to be ≥ 0.993 for PTZ and (r2) ≥ 0.990 for LS. The lower limit of quantification for PTZ was 3.5 ng/mL and LS was 3.0 ng/mL. The intra and inter day precision and accuracy for PTZ and LS were within the limits fulfilling the international acceptance criteria. PTZ and LS were found to be stable throughout three freeze-thaw cycles, bench top and short term stability studies. Conclusion: The proposed validated LC-MS/MS method offers a sensitive quantification of PTZ and LS in spiked human plasma and can be utilized for the quantification of PTZ and LS in real-time samples.


Biomedicines ◽  
2021 ◽  
Vol 9 (6) ◽  
pp. 621
Author(s):  
Aurélien Millet ◽  
Nihel Khoudour ◽  
Jérôme Guitton ◽  
Dorothée Lebert ◽  
François Goldwasser ◽  
...  

Pembrolizumab is a humanized immunoglobulin G4-kappa anti-PD1 antibody used in the treatment of different solid tumors or haematological malignancies. A liquid chromatography coupled with a high resolution mass spectrometry (orbitrap technology) method was fully developed, optimized, and validated for quantitative analysis of pembrolizumab in human plasma. A mass spectrometry assay was used for the first time a full-length stable isotope-labelled pembrolizumab-like (Arginine 13C6-15N4 and Lysine 13C6-15N2) as an internal standard; the sample preparation was based on albumin depletion and trypsin digestion and, finally, one surrogate peptide was quantified in positive mode. The assay showed good linearity over the range of 1–100 μg/mL, a limit of quantification at 1 μg/mL, excellent accuracy from 4.4% to 5.1%, and also a between-day precision below 20% at the limit of quantification. In parallel, an in-house ELISA was developed with a linearity range from 2.5 to 50 µg/mL. Then, results were obtained from 70 plasma samples of cancer patients that were treated with pembrolizumab and quantified with both methods were compared using the Passing-Bablok regression analysis and Bland-Altman plotting. The LC-MS/HRMS method is easy to implement in the laboratory for use in the context of PK/PD studies, clinical trials, or therapeutic drug monitoring.


Sign in / Sign up

Export Citation Format

Share Document