scholarly journals Configuration and Digital Simulation of STATCOM utilizing 48-Pulse VSC for Reactive Power Reparation and Potential Reliability

2020 ◽  
Vol 2 (1) ◽  
pp. 1-15
Author(s):  
Sundar Govindasamy ◽  
Ashok Rangaswamy

This paper analyzes the configuration of Static Synchronous Compensator-STATCOM utilizing 48 pulse voltage source converter for reactive force reparation and voltage adjustment in force framework transmission and dispersion systems alongside the advanced development of the STATCOM utilizing 48 pulse VSC, expecting framework subjected to unsettling disturbances of real and reactive power. The 48 Pulse voltage source converter is composed with the guide of four 3-level voltage source converters exchanging at the major recurrence to create a sinusoidal yield voltage with decreased symphonies substance. The outline and computerized recreation of STATCOM has been executed in the MATLAB/Simulink stage. It is strongly evident that the outcome of reactive power reparation and voltage stabilization have been substantially improved by the proposed STATCOM configuration with 48 pulse VSC.

2021 ◽  
Vol 11 (16) ◽  
pp. 7330
Author(s):  
L. Narayana Gadupudi ◽  
Gudapati Sambasiva Rao ◽  
Ramesh Devarapalli ◽  
Fausto Pedro García Márquez

Flexible alternating current transmission system (FACTS) controllers are important to enhance the quality of power in power systems. The stability of a system is achieved via a FACTS device (a Static Synchronous Compensator (STATCOM)). This paper aims to control the losses in the transmission system during peak energy demand circumstances with minimal losses in the economical and functional efficiency of the system. The STATCOM operation of a seven level voltage source converter (VSC) with binary-weighted transformers is proposed for controlling the reactive power variations and terminal voltage changes at dynamic circumstances in the transmission system. The STATCOM is operated at 132 kV and is a 50 Hz AC system with a single DC-Link capacitance and two VSC power circuits. Each VSC circuit consists of three H-bridges with specific switching angle control in order to achieve low total harmonic distortion at the fundamental frequency. The coupled control circuit phenomenon is imperative for computing the switching angle for a stable performance. The dynamic functional improvement efficiency is harvested with a minimum number of switches and transformers used in high voltage and high-power applications. The number of switches, transformers, and capacitors for 132 kV are optimized with a proposed STATCOM operation in seven level VSC with binary-weighted transformers. The simulated results prove that the proposed model significantly improved system performance and stability.


2018 ◽  
Vol 7 (4.10) ◽  
pp. 206
Author(s):  
Srikanth Velpula ◽  
Thirumalaivasan R ◽  
Janaki M

The Static Synchronous Compensator (STATCOM) is a Voltage Source Converter (VSC) based shunt connected FACTS device. The key roles of STATCOM are to control the voltage at midpoint of transmission line, enhance power transfer capability and control reactive power at load end. However, the performance of STATCOM depends upon the parameters of the controller. In this paper, we present the tuning of Type-1 controller parameters for STATCOM based on a systematic method using Flower Pollination Algorithm (FPA). The margins for the Type-1 controller parameters are estimated from the movement of eigenvalues for the variation in controller parameters during inductive and capacitive modes of STATCOM. The performance of the STATCOM with FPA optimized Type-1 controller parameters is evaluated by transient simulation. The eigenvalue analysis and transient simulation are done based on D-Q model of STATCOM. It is noticed that, the response of STATCOM follows the step change in reactive current reference with least error.  


Author(s):  
Akram Qashou ◽  
Sufian Yousef ◽  
Abdallah A. Smadi ◽  
Amani A. AlOmari

AbstractThe purpose of this paper is to describe the design of a Hybrid Series Active Power Filter (HSeAPF) system to improve the quality of power on three-phase power distribution grids. The system controls are comprise of Pulse Width Modulation (PWM) based on the Synchronous Reference Frame (SRF) theory, and supported by Phase Locked Loop (PLL) for generating the switching pulses to control a Voltage Source Converter (VSC). The DC link voltage is controlled by Non-Linear Sliding Mode Control (SMC) for faster response and to ensure that it is maintained at a constant value. When this voltage is compared with Proportional Integral (PI), then the improvements made can be shown. The function of HSeAPF control is to eliminate voltage fluctuations, voltage swell/sag, and prevent voltage/current harmonics are produced by both non-linear loads and small inverters connected to the distribution network. A digital Phase Locked Loop that generates frequencies and an oscillating phase-locked output signal controls the voltage. The results from the simulation indicate that the HSeAPF can effectively suppress the dynamic and harmonic reactive power compensation system. Also, the distribution network has a low Total Harmonic Distortion (< 5%), demonstrating that the designed system is efficient, which is an essential requirement when it comes to the IEEE-519 and IEC 61,000–3-6 standards.


Author(s):  
Anjana Jain ◽  
R. Saravanakumar ◽  
S. Shankar ◽  
V. Vanitha

Abstract The variable-speed Permanent Magnet Synchronous Generator (PMSG) based Wind Energy Conversion System (WECS) attracts the maximum power from wind, but voltage-regulation and frequency-control of the system in standalone operation is a challenging task A modern-control-based-tracking of power from wind for its best utilization is proposed in this paper for standalone PMSG based hybrid-WECS comprising Battery Energy Storage System (BESS). An Adaptive Synchronous Reference Frame Phase-Locked-Loop (SRF-PLL) based control scheme for load side bi-directional voltage source converter (VSC) is presented for the system. MATLAB/Simulink model is developed for simulation study for the proposed system and the effectiveness of the controller for bi-directional-converter is discussed under different operating conditions: like variable wind-velocity, sudden load variation, and load unbalancing. Converter control scheme enhances the power smoothening, supply-load power-matching. Also it is able to regulate the active & reactive power from PMSG-BESS hybrid system with control of fluctuations in voltage & frequency with respect to varying operating conditions. Proposed controller successfully offers reactive-power-compensation, harmonics-reduction, and power-balancing. The proposed scheme is based on proportional & integral (PI) controller. Also system is experimentally validated in the laboratory-environment and results are presented here.


2018 ◽  
Vol 2018 ◽  
pp. 1-16 ◽  
Author(s):  
Tian Hao Huang ◽  
Kuo Lung Lian

In response to the growing demand for medium- and high-power trends, multilevel voltage source converters (VSCs) have been attracting growing considerations. One of the widely used VSCs are the diode-clamped multilevel VSC (DCM-VSC). As these converters proliferate, their harmonic impact may become significant. Nevertheless, a harmonic model for the DCM-VSC is currently lacking in the literature. In this paper, the ABCD matrix, mapping the input harmonics to the output harmonics of DCM-VSC, is derived. As the matrix is formulated in the time-domain, the output harmonics are exact and do not suffer from harmonic truncation errors. As the paper will demonstrate, the derived ABCD matrix can be easily applied to a microgrid system and users can easily predict all the uncharacteristic harmonics when a microgrid is subjected to various conditions of imbalance. In addition to all the results being validated with those of PSCAD/EMTDC, the computation time of the proposed method is in contrast much shorter.


Energies ◽  
2020 ◽  
Vol 13 (9) ◽  
pp. 2260
Author(s):  
Fan Cheng ◽  
Lijun Xie ◽  
Zhibing Wang

This paper investigated the characteristics of a novel type of hybrid high voltage direct current (HVdc) converter, which is composed by line commutated converter series with voltage source converter. The system and valve level control strategies are introduced, which can provide ac system voltage support. A novel filter design scheme composed by resonant filers for hybrid HVdc are also proposed, which can decrease the capacity of reactive power compensation equipment without deteriorate harmonic characteristics. The ac voltage of HVdc fluctuation level caused by transmitted power variation will be effectively reduced, with the coordination between filter design scheme and converter control. In addition, the influence of ac grid strength is also analyzed by equivalent source internal impedance represented by short circuit ratio (SCR). Finally, the +800 kV/1600 MW hybrid HVdc system connecting two ac grids under different SCR cases are studied, and the PSCAD/EMTDC simulation results have validated the effectiveness for proposed strategy.