scholarly journals Analisis Kinerja Struktur Rangka Beton Bertulang Beraturan Dengan Penambahan Tingkat Menggunakan Struktur Baja

2021 ◽  
Vol 1 (2) ◽  
pp. 36-47
Author(s):  
Hilario Alberto Kono ◽  
Partogi H Simatupang ◽  
Ruslan Ramang

The change of plans on gradually development in building structure can be occur with building operational consideration and owner financial. The purpose of this study was to determine the level of performance of the reinforced concrete frame structure with additional levels using steel structures with different span variations. The results of the analysis are used to determine how big the deviation is between levels and to control the level of structure performance. The conclusion of the study shows that the performance level of the structural model analyzed is immediate occupancy (IO) with a total drift ratio and interstorey drift ratio value of the initial building structure (C3S0) in the x direction and y direction of 0.0004, and for variations in building structure with the addition of levels using steel structures (C3S1, C3S2, C5S1, C5S2, C7S1, C7S2) in the x direction ranging from 0.0005-0.0007 and in the y direction ranging from 0.0010-0.0024.

2012 ◽  
Vol 204-208 ◽  
pp. 869-871
Author(s):  
Cai Hua Wang ◽  
Hui Jian Li ◽  
Jian Feng Wu

The multi-storey reinforced concrete frame structure used lead rubber pad as the base isolation device. The paper had modal analysis of base-isolated multi-storey reinforced concrete frame structure using the ANSYS software. Comparing the frequency and vibration mode before and after isolation under El-Centro wave, It concluded the leader rubber pad have seismic isolation effect for multi-storey reinforced concrete frame structure .


1999 ◽  
Vol 26 (5) ◽  
pp. 606-617 ◽  
Author(s):  
A C Heidebrecht ◽  
N Naumoski

This paper describes an investigation into the seismic performance of a six-storey ductile moment-resisting frame structure located in Vancouver and designed and detailed in accordance with the seismic provisions of the National Building Code of Canada (1995). Both pushover and dynamic analyses are conducted using an inelastic model of the structure as designed and detailed. The structural performance of a number of design variations is evaluated using interstorey drift and member curvature ductility response as performance measures. All frames studied are expected to perform at an operational level when subjected to design level seismic excitations and to meet life safe performance criteria at excitations of twice the design level.Key words: seismic, building, frames, ductile, design, performance, reinforced concrete, code.


2012 ◽  
Vol 193-194 ◽  
pp. 1109-1112
Author(s):  
Li Ming Wu ◽  
Xiao Liang Luo ◽  
Zi Jian Wang

Taking a 5-story reinforced concrete frame structure on the transformed 3-layer steel frames for an example, use finite element software ANSYS to reformation as a whole building model under static wind load changes for comparative analysis of internal force and displacement of the corresponding node. Analysis results show that in the transformation of steel on reinforced concrete frame structure, should fully take into account the structural stiffness change on construction of the overall effect of wind resistance, so that the transformation of the steel concrete frame structure more reasonable.


Sign in / Sign up

Export Citation Format

Share Document