scholarly journals HARDWARE OF MONITORING THE IDENTITY OF OPERATING CYCLES OF DIESEL GENERATOR

2021 ◽  
Author(s):  
S. G. Ignatiev ◽  
S. V. Kiseleva

Optimization of the autonomous wind-diesel plants composition and of their power for guaranteed energy supply, despite the long history of research, the diversity of approaches and methods, is an urgent problem. In this paper, a detailed analysis of the wind energy characteristics is proposed to shape an autonomous power system for a guaranteed power supply with predominance wind energy. The analysis was carried out on the basis of wind speed measurements in the south of the European part of Russia during 8 months at different heights with a discreteness of 10 minutes. As a result, we have obtained a sequence of average daily wind speeds and the sequences constructed by arbitrary variations in the distribution of average daily wind speeds in this interval. These sequences have been used to calculate energy balances in systems (wind turbines + diesel generator + consumer with constant and limited daily energy demand) and (wind turbines + diesel generator + consumer with constant and limited daily energy demand + energy storage). In order to maximize the use of wind energy, the wind turbine integrally for the period in question is assumed to produce the required amount of energy. For the generality of consideration, we have introduced the relative values of the required energy, relative energy produced by the wind turbine and the diesel generator and relative storage capacity by normalizing them to the swept area of the wind wheel. The paper shows the effect of the average wind speed over the period on the energy characteristics of the system (wind turbine + diesel generator + consumer). It was found that the wind turbine energy produced, wind turbine energy used by the consumer, fuel consumption, and fuel economy depend (close to cubic dependence) upon the specified average wind speed. It was found that, for the same system with a limited amount of required energy and high average wind speed over the period, the wind turbines with lower generator power and smaller wind wheel radius use wind energy more efficiently than the wind turbines with higher generator power and larger wind wheel radius at less average wind speed. For the system (wind turbine + diesel generator + energy storage + consumer) with increasing average speed for a given amount of energy required, which in general is covered by the energy production of wind turbines for the period, the maximum size capacity of the storage device decreases. With decreasing the energy storage capacity, the influence of the random nature of the change in wind speed decreases, and at some values of the relative capacity, it can be neglected.


2020 ◽  
Vol 65 (1) ◽  
pp. 163-170
Author(s):  
Eugen Răduca

The paper presents a model of centrifugal equipment for extracting honey made around an ATmega 328 processor, with which the Arduino Uno module is equipped. The created model is functional, being tested, and the practical results obtained would allow the transition to prototype equipment. The created model is flexible, allowing to obtain flexible operating cycles, with variable speeds, soft settable, in both directions of rotation. The number of frames from which the bee honey can be extracted is variable depending on the juicer itself, which is driven by the motor


2016 ◽  
Vol 20 (3) ◽  
pp. 74-79
Author(s):  
E.A. Abidova ◽  
L.S. Hegay ◽  
A.V. Chernov ◽  
V.A. Bulava ◽  
O.Yu. Pugachyova ◽  
...  

Author(s):  
Larissa Santos Queiroz ◽  
Sara Leão ◽  
Ana Lídia Santos ◽  
Nelson Rocha ◽  
Ricardo Pereira ◽  
...  

Author(s):  
Ana Lídia Santos ◽  
Nelson Rocha ◽  
Larissa Santos Queiroz ◽  
Luiz Claudio Marques ◽  
Hendrick Zarate Rocha

Energies ◽  
2021 ◽  
Vol 14 (7) ◽  
pp. 1988
Author(s):  
Ioannis E. Kosmadakis ◽  
Costas Elmasides

Electricity supply in nonelectrified areas can be covered by distributed renewable energy systems. The main disadvantage of these systems is the intermittent and often unpredictable nature of renewable energy sources. Moreover, the temporal distribution of renewable energy may not match that of energy demand. Systems that combine photovoltaic modules with electrical energy storage (EES) can eliminate the above disadvantages. However, the adoption of such solutions is often financially prohibitive. Therefore, all parameters that lead to a functionally reliable and self-sufficient power generation system should be carefully considered during the design phase of such systems. This study proposes a sizing method for off-grid electrification systems consisting of photovoltaics (PV), batteries, and a diesel generator set. The method is based on the optimal number of PV panels and battery energy capacity whilst minimizing the levelized cost of electricity (LCOE) for a period of 25 years. Validations against a synthesized load profile produced grid-independent systems backed by different accumulator technologies, with LCOEs ranging from 0.34 EUR/kWh to 0.46 EUR/kWh. The applied algorithm emphasizes a parameter of useful energy as a key output parameter for which the solar harvest is maximized in parallel with the minimization of the LCOE.


2020 ◽  
Vol 13 (1) ◽  
pp. 93
Author(s):  
Wesam H. Beitelmal ◽  
Paul C. Okonkwo ◽  
Fadhil Al Housni ◽  
Wael Alruqi ◽  
Omar Alruwaythi

Diesel generators are being used as a source of electricity in different parts of the world. Because of the significant expense in diesels cost and the requirement for a greener domain, such electric generating systems appear not to be efficient and environmentally friendly and should be tended to. This paper explores the attainability of utilizing a sustainable power source based on a cross-breed electric system in the cement factory in Salalah, Oman. The HOMER software that breaks down the system setup was utilized to examine the application and functional limitations of each hybridized plan. The result showed that a renewable-energy (RE)-based system has a lower cost of energy (COE) and net present cost (NPC) compared to diesel generator-based hybrid electric and standalone systems. Although the two pure renewable hybrid energy systems considered in this study displayed evidence of no emissions, lower NPC and COE values are observed in the photovoltaic/battery (PV/B) hybrid energy system compared with photovoltaic/wind turbine/battery (PV/WT/B). The PV/WT/B and PV/B systems have higher electricity production and low NPC and COE values. Moreover, the PV/B has the highest return on investment (ROI) and internal rate of return (IRR), making the system the most economically viable and adjudged to be a better candidate for rural community electrification demands.


Author(s):  
Salah K. Kanaan ◽  
Amer Omanovic

In 2004, a decision was made to perform a modernization and a new power uprate of unit 2 at Oskarshamn nuclear power plant in Sweden. Among the most important reasons for this decision were new safety regulations from Swedish Radiation Safety Authority and ageing of important components. A project was established and became the largest nuclear power modernization in the world. The modernization led to the need of analysing the auxiliary power system to ensure that it could supply the unit after the uprate, given tolerances on current, voltage and frequency. During the process of developing models for the diesel generator sets, it turned out that the suppliers could not deliver enough satisfactory material for modelling the diesel engines, the speed controllers and the magnetization systems. Therefore, Oskarshamn nuclear power plant with the help of the manufacturers of the diesel generator sets carried out additional measurements in order to collect data for modelling. Based on electric circuit diagrams provided by the manufacturers, block diagrams of the magnetization systems were made. For the speed controllers, no information was available at all so it was assumed that the controller was of PI-type. The parameters of the magnetization systems and the speed controllers were then tuned using the measurement results. Finally, a comparison between simulated results and the measurement results were made, showing good agreement. This is especially true in the most commonly used operating interval of the diesel generator sets.


Clean Energy ◽  
2021 ◽  
Vol 5 (2) ◽  
pp. 254-272
Author(s):  
C Palanichamy ◽  
P Naveen

Abstract In 2018, the Government of India approved the establishment of the New All India Institute of Medical Sciences (AIIMS) in Thoppur, Madurai, Tamil Nadu, India. As the most important amenity for continuing primary care and rescue response is a healthcare facility, a secure electricity supply becomes an imperative necessity. Hence, as the energy supplier for the new AIIMS, Madurai, this paper proposes a microgrid combined with the utility grid. The microgrid consists of a 4-MW photovoltaic system, a 1.8-MW wind-turbine energy-conversion system, a backup diesel generator capable of meeting the forecasted maximum demand and a 1-MW battery energy-storage system. The AIIMS Microgrid will have a service providing a capacity of 20 MVA following integration with the utility grid. The proposed microgrid would be the first attempt at healthcare facilities in India since its first day of work to ensure the availability of electricity. It would have a 9.8% return on investment, a 13.6% internal rate of return and a payback period of 6.75 years once it is operational, as well as an attractive levelized cost of energy (LCOE) of USD 0.07547/kWh. It would provide an environmentally friendly atmosphere by avoiding an annual emission of 6 261 132 kg of carbon dioxide, 27 362 kg of sulphur dioxide and 12 838 kg of nitrogen oxides as compared to power supplied entirely from the utility grid.


2010 ◽  
Vol 179 (1-3) ◽  
pp. 237-243 ◽  
Author(s):  
Jen-Hsiung Tsai ◽  
Shui-Jen Chen ◽  
Kuo-Lin Huang ◽  
Yuan-Chung Lin ◽  
Wen-Jhy Lee ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document