scholarly journals Algorithm for Computation of DCT and its Implementation using a Systolic Architecture

In this paper a new algorithm for computing N-point DCT, where N=4r, r>1 is presented. A new algorithm has been derived that can compute the 1D DCT and it is realized in systolic array that utilizes identical processing elements (PE’s). The proposed approach can be used to obtain other transform like Discrete Sine Transform (DST), Discrete Hartley Transform (DHT). The suggested algorithm requires reduced number of multiplications as compared to the other methods of computing DCT. This suggests structure meets the architectural challenge and it is simple, regular design and cost-effective for special-purpose system.

2020 ◽  
pp. 1192-1198
Author(s):  
M.S. Mohammad ◽  
Tibebe Tesfaye ◽  
Kim Ki-Seong

Ultrasonic thickness gauges are easy to operate and reliable, and can be used to measure a wide range of thicknesses and inspect all engineering materials. Supplementing the simple ultrasonic thickness gauges that present results in either a digital readout or as an A-scan with systems that enable correlating the measured values to their positions on the inspected surface to produce a two-dimensional (2D) thickness representation can extend their benefits and provide a cost-effective alternative to expensive advanced C-scan machines. In previous work, the authors introduced a system for the positioning and mapping of the values measured by the ultrasonic thickness gauges and flaw detectors (Tesfaye et al. 2019). The system is an alternative to the systems that use mechanical scanners, encoders, and sophisticated UT machines. It used a camera to record the probe’s movement and a projected laser grid obtained by a laser pattern generator to locate the probe on the inspected surface. In this paper, a novel system is proposed to be applied to flat surfaces, in addition to overcoming the other limitations posed due to the use of the laser projection. The proposed system uses two video cameras, one to monitor the probe’s movement on the inspected surface and the other to capture the corresponding digital readout of the thickness gauge. The acquired images of the probe’s position and thickness gauge readout are processed to plot the measured data in a 2D color-coded map. The system is meant to be simpler and more effective than the previous development.


2020 ◽  
Vol 9 (1) ◽  
pp. 67
Author(s):  
Seung-Min Yang ◽  
Jiwon Baek ◽  
Eiseul Kim ◽  
Hyeon-Be Kim ◽  
Seyoung Ko ◽  
...  

In recent years, Salmonella Infantis has become a predominant serovariant in clinical and poultry isolates, thereby imposing a substantial economic burden on both public health and the livestock industry. With the aim of coping with the steep increase in serovar Infantis prevalence, a polymerase chain reaction (PCR)-based rapid and accurate diagnostic assay was developed in this study through pangenome profiling of 60 Salmonella serovars. A gene marker, SIN_02055, was identified, which is present in the S. Infantis genome but not in the pangenome of the other serovars. Primers specific to SIN_02055 were used to accurately detect serovar Infantis, and to successfully differentiate Infantis from the other 59 serovars in real-time PCR with a R2 of 0.999 and an efficiency of 95.76%. The developed method was applied to 54 Salmonella strains belonging to eight dominant serovars, and distinguished Infantis from the other seven serovars with an accuracy of 100%. The diagnostic primer set also did not show false positive amplification with 32 strains from eight non-Salmonella bacterial species. This cost-effective and rapid method can be considered an alternative to the classic serotyping using antisera.


Sign in / Sign up

Export Citation Format

Share Document