2D Color-Intensity Representation of Ultrasonic Thickness Gauge Measurements

2020 ◽  
pp. 1192-1198
Author(s):  
M.S. Mohammad ◽  
Tibebe Tesfaye ◽  
Kim Ki-Seong

Ultrasonic thickness gauges are easy to operate and reliable, and can be used to measure a wide range of thicknesses and inspect all engineering materials. Supplementing the simple ultrasonic thickness gauges that present results in either a digital readout or as an A-scan with systems that enable correlating the measured values to their positions on the inspected surface to produce a two-dimensional (2D) thickness representation can extend their benefits and provide a cost-effective alternative to expensive advanced C-scan machines. In previous work, the authors introduced a system for the positioning and mapping of the values measured by the ultrasonic thickness gauges and flaw detectors (Tesfaye et al. 2019). The system is an alternative to the systems that use mechanical scanners, encoders, and sophisticated UT machines. It used a camera to record the probe’s movement and a projected laser grid obtained by a laser pattern generator to locate the probe on the inspected surface. In this paper, a novel system is proposed to be applied to flat surfaces, in addition to overcoming the other limitations posed due to the use of the laser projection. The proposed system uses two video cameras, one to monitor the probe’s movement on the inspected surface and the other to capture the corresponding digital readout of the thickness gauge. The acquired images of the probe’s position and thickness gauge readout are processed to plot the measured data in a 2D color-coded map. The system is meant to be simpler and more effective than the previous development.

2005 ◽  
Vol 11 (4) ◽  
pp. 167-177 ◽  
Author(s):  
Paul Taylor

The evaluation of telemedicine involves attempts to answer a wide range of questions involved in making decisions about safety, about practicality and about utility. Roughly speaking, if we wish to provide a telemedicine service we should first establish that it is safe, next that it is practical and finally that it is worthwhile. In establishing safety, most laboratory studies of telemedicine have a common structure, and consist of the following steps: (1) selection of cases; (2) interpretation; (3) comparison with a gold standard; (4) statistical analyses. Most of the studies to establish the practicality of telemedicine have been carried out as demonstrations, to show that a proposed application can be implemented in a chosen setting. In terms of utility, telemedicine has been used to improve the efficiency of an existing service or to make an existing service available to a new community. One of the difficulties is that the vendors of relatively expensive telemedicine systems and services disseminate much of the information on the topic. We have to focus not on the glamorous technology but on the underlying issue of how the participants in health care (patients, general practitioners, specialists) can communicate more effectively, using the range of technological options open to them. Ensuring that the most appropriate technology is used in the most effective way should be the primary aim of telemedicine research. There is now sufficient evidence for us to be confident that telemedicine is a safe alternative to conventional care in a variety of situations and for a number of clinical conditions. Reliable evidence that it is a practical and cost-effective alternative is, at the time of writing, harder to find.


1997 ◽  
Vol 27 (3) ◽  
pp. 175-182 ◽  
Author(s):  
Christine STOREY ◽  
Júlia Ignez SALEM

The Brazilian State of Amazonas has a high incidence of Tuberculosis, 91.4 in 10,000 habitants (SESAU, 1994) and resistant strains of Mycobacterium tuberculosis are frequently being found in the region (SALEM et.al, 1990). These problems have been associated with side effects caused by the antibiotics used to treat Tuberculosis, which have in rum been associated with treatment non-compliance (PATTISAPU, 1984). To resolve this problem a cost effective alternative treatment for Tuberculosis with few or no side effects, needs to be found. Amazonas has an abundance of plants, many of which are used by the lay population for medicinal purposes. A survey was carried out in five towns of the region, interviewing patients receiving treatment for Tuberculosis, to find out whether and which plants have been used to treat Tuberculosis. Results showed that the majority of patients in the sample had used medicinal plants before or after diagnosis of Tuberculoses. Thirteen different plants were recorded for this purpose. Chenopodium ambrosioides L, popularly known as Mastruz, was the most commonly used, followed by Caesalpinia ferrea Mart. Jucá and Spilanthes acmella DC. Jambu. This study concentrates on Mastruz as it was used more frequently than the other medicinal plants. No significant effects on baciloscopy test results were found when Mastruz was used before diagnosis. ln-vitro laboratory tests have also not shown any tuberculocidal effects for Mastruz. Further tests are being carried out on the other medicinal plants.


Alloy Digest ◽  
1980 ◽  
Vol 29 (11) ◽  

Abstract JS777 is a high-alloy, fully austenitic stainless steel developed for applications where corrosive conditions are too severe for the standard grades of stainless steel. It also provides a cost-effective alternative to more expensive nickel-base and titanium-base alloys. It has relatively high resistance to stress-corrosion cracking and to intergranular corrosion. This datasheet provides information on composition, physical properties, hardness, elasticity, and tensile properties. It also includes information on corrosion resistance as well as forming, heat treating, machining, joining, and surface treatment. Filing Code: SS-377. Producer or source: Jessop Steel Company.


Alloy Digest ◽  
2009 ◽  
Vol 58 (11) ◽  

Abstract Ancorsteel 4300 alloy ferrous powder simulates wrought steel compositions and is a cost-effective alternative to alloys requiring secondary processing. This datasheet provides information on composition, physical properties, hardness, and tensile properties as well as fracture toughness. It also includes information on heat treating and powder metal forms. Filing Code: SA-611. Producer or source: Hoeganaes Corporation.


2020 ◽  
Vol 24 ◽  
Author(s):  
Bubun Banerjee ◽  
Gurpreet Kaur ◽  
Navdeep Kaur

: Metal-free organocatalysts are becoming an important tool for the sustainable developments of various bioactive heterocycles. On the other hand, during last two decades, calix[n]arenes have been gaining considerable attention due to their wide range of applicability in the field of supramolecular chemistry. Recently, sulfonic acid functionalized calix[n] arenes are being employed as an efficient alternative catalyst for the synthesis of various bioactive scaffolds. In this review we have summarized the catalytic efficiency of p-sulfonic acid calix[n]arenes for the synthesis of diverse biologically promising scaffolds under various reaction conditions. There is no such review available in the literature showing the catalytic applicability of p-sulfonic acid calix[n]arenes. Therefore, we strongly believe that this review will surely attract those researchers who are interested about this fascinating organocatalyst.


Author(s):  
Allan Matthews ◽  
Adrian Leyland

Over the past twenty years or so, there have been major steps forward both in the understanding of tribological mechanisms and in the development of new coating and treatment techniques to better “engineer” surfaces to achieve reductions in wear and friction. Particularly in the coatings tribology field, improved techniques and theories which enable us to study and understand the mechanisms occurring at the “nano”, “micro” and “macro” scale have allowed considerable progress to be made in (for example) understanding contact mechanisms and the influence of “third bodies” [1–5]. Over the same period, we have seen the emergence of the discipline which we now call “Surface Engineering”, by which, ideally, a bulk material (the ‘substrate’) and a coating are combined in a way that provides a cost-effective performance enhancement of which neither would be capable without the presence of the other. It is probably fair to say that the emergence and recognition of Surface Engineering as a field in its own right has been driven largely by the availability of “plasma”-based coating and treatment processes, which can provide surface properties which were previously unachievable. In particular, plasma-assisted (PA) physical vapour deposition (PVD) techniques, allowing wear-resistant ceramic thin films such as titanium nitride (TiN) to be deposited on a wide range of industrial tooling, gave a step-change in industrial productivity and manufactured product quality, and caught the attention of engineers due to the remarkable cost savings and performance improvements obtained. Subsequently, so-called 2nd- and 3rd-generation ceramic coatings (with multilayered or nanocomposite structures) have recently been developed [6–9], to further extend tool performance — the objective typically being to increase coating hardness further, or extend hardness capabilities to higher temperatures.


Biostatistics ◽  
2019 ◽  
Author(s):  
Dane R Van Domelen ◽  
Emily M Mitchell ◽  
Neil J Perkins ◽  
Enrique F Schisterman ◽  
Amita K Manatunga ◽  
...  

SUMMARYMeasuring a biomarker in pooled samples from multiple cases or controls can lead to cost-effective estimation of a covariate-adjusted odds ratio, particularly for expensive assays. But pooled measurements may be affected by assay-related measurement error (ME) and/or pooling-related processing error (PE), which can induce bias if ignored. Building on recently developed methods for a normal biomarker subject to additive errors, we present two related estimators for a right-skewed biomarker subject to multiplicative errors: one based on logistic regression and the other based on a Gamma discriminant function model. Applied to a reproductive health dataset with a right-skewed cytokine measured in pools of size 1 and 2, both methods suggest no association with spontaneous abortion. The fitted models indicate little ME but fairly severe PE, the latter of which is much too large to ignore. Simulations mimicking these data with a non-unity odds ratio confirm validity of the estimators and illustrate how PE can detract from pooling-related gains in statistical efficiency. These methods address a key issue associated with the homogeneous pools study design and should facilitate valid odds ratio estimation at a lower cost in a wide range of scenarios.


2021 ◽  
Vol 80 (Suppl 1) ◽  
pp. 119-120
Author(s):  
N. Østerås ◽  
E. Aas ◽  
T. Moseng ◽  
L. Van Bodegom-Vos ◽  
K. Dziedzic ◽  
...  

Background:To improve quality of care for patients with hip and knee osteoarthritis (OA), a structured model for integrated OA care was developed based on international treatment recommendations. A previous analysis of a cluster RCT (cRCT) showed that compared to usual care, the intervention group reported higher quality of care and greater satisfaction with care. Also, more patients were treated according to international guidelines and fulfilled recommendations for physical activity at the 6-month follow-up.Objectives:To assess the cost-utility of a structured model for hip or knee OA care.Methods:A cRCT with stepped-wedge cohort design was conducted in 6 Norwegian municipalities (clusters) in 2015-17. The OA care model was implemented in one cluster at the time by switching from “usual care” to the structured model. The implementation of the model was facilitated by interactive workshops for general practitioners (GPs) and physiotherapists (PTs) with an update on OA treatment recommendations. The GPs explained the OA diagnosis and treatment alternatives, provided pharmacological treatment when appropriate, and suggested referral to physiotherapy. The PT-led patient OA education programme was group-based and lasted 3 hours followed by an 8–12-week individually tailored resistance exercise programme with twice weekly 1-hour supervised group sessions (5–10 patients per PT). An optional 10-hours Healthy Eating Program was available. Participants were ≥45 years with symptomatic hip or knee OA.Costs were measured from the healthcare perspective and collected from several sources. Patients self-reported visits in primary healthcare at 3, 6, 9 and 12 months. Secondary healthcare visits and joint surgery data were extracted from the Norwegian Patient Register. The health outcome, quality-adjusted life-year (QALY), was estimated based on the EQ-5D-5L scores at baseline, 3, 6, 9 and 12 months. The result of the cost-utility analysis was reported using the incremental cost-effectiveness ratio (ICER), defined as the incremental costs relative to incremental QALYs (QALYs gained). Based on Norwegian guidelines, the threshold is €27500. Sensitivity analyses were performed using bootstrapping to assess the robustness of reported results and presented in a cost-effectiveness plane (Figure 1).Results:The 393 patients’ mean age was 63 years (SD 9.6) and 74% were women. 109 patients were recruited during control periods (control group), and 284 patients were recruited during interventions periods (intervention group). Only the intervention group had a significant increase in EQ-5D-5L utility scores from baseline to 12 months follow-up (mean change 0.03; 95% CI 0.01, 0.05) with QALYs gained: 0.02 (95% CI -0.08, 0.12). The structured OA model cost approx. €301 p.p. with an additional €50 for the Healthy Eating Program. Total 12 months healthcare cost p.p. was €1281 in the intervention and €3147 in the control group, resulting in an incremental cost of -€1866 (95% CI -3147, -584) p.p. Costs related to surgical procedures had the largest impact on total healthcare costs in both groups. During the 12-months follow-up period, 5% (n=14) in the intervention compared to 12% (n=13) in the control group underwent joint surgery; resulting in a mean surgical procedure cost of €553 p.p. in the intervention as compared to €1624 p.p. in the control group. The ICER was -€93300, indicating that the OA care model resulted in QALYs gained and cost-savings. At a threshold of €27500, it is 99% likely that the OA care model is a cost-effective alternative.Conclusion:The results of the cost-utility analysis show that implementing a structured model for OA care in primary healthcare based on international guidelines is highly likely a cost-effective alternative compared to usual care for people with hip and knee OA. More studies are needed to confirm this finding, but this study results indicate that implementing structured OA care models in primary healthcare may be beneficial for the individual as well as for the society.Disclosure of Interests:None declared


Sign in / Sign up

Export Citation Format

Share Document