scholarly journals Magnetic Resonance Spectroscopic and Histopathological Findings in the Supratentorial Brain Space Occupying Lesions

2020 ◽  
Vol 24 (3) ◽  
Author(s):  
ASAD ABBAS ◽  
FARRUKH JAVEED ◽  
LAL REHMAN ◽  
ALI AFZAL ◽  
RAZA KHAIRAT RIZVI

Objective:  Diagnosis of supratentorial space occupying lesion is a frequent dilemma in neurosurgical practice. MR spectroscopy that is an advanced MR imaging sequence can prove to be decisive in such cases. The objective of the study is to determine diagnostic accuracy of MRS in differentiating supra-tentorial brain space occupying lesions taking histopathology as gold standard Material and Methods:  The cross sectional study was conducted at Department of Neurosurgery, Jinnah Postgraduate Medical Centre, Karachi from August 2018 to July 2019. A calculated sample size of 156 patients aged between 18-50 years after informed consent. All patients underwent MR Spectroscopy pre-operatively. Surgery was performed and histopathological findings were compared with spectroscopic findings. Results:  The average age of the patients was 32.41 ± 10.02 years. There were 84 (53.84%) males and 72 (46.15%) females. The sensitivity of MRS was 90.69% with a specificity of 97.34%. Conclusion:  MR Spectroscopy is an accurate diagnostic tool for establishing pre-operative differentiation between neoplastic and inflammatory lesion. It should be performed in all cases where contrast MRI is inconclusive in establishing the diagnosis. Keywords:  , Brain Abscess, Supratentorial lesion, Brain Tumor

1994 ◽  
Vol 34 (7) ◽  
pp. 435-438 ◽  
Author(s):  
Nijasri Suwanwela ◽  
Kammant Phanthumchinda ◽  
Surachai Kaoropthum

Author(s):  
Merylin Ranoko ◽  
Aryati Aryati ◽  
Arifoel Hajat

Malaria remains a health problem in Indonesia. Microscopic examination with Giemsa staining is the gold standard for diagnosing malaria. The density of parasites correlates with the degree of severity and response to therapy of malaria. Malaria-causing plasmodium can be detected by Sysmex XN-1000 which is marked by abnormalities in the WDF, WNR and RET scattergram. This research aimed to determine the correlation of WDF, WNR and RET abnormal scattergram detected by Sysmex XN-1000 and the parasitemia index of malaria at the Merauke General Hospital. This was a cross-sectional study with observational approach conducted between November 2017 – February 2018 at the Merauke General Hospital. Positive malaria samples were stained with Giemsa, their parasitemia index was calculated, routine complete blood count using Sysmex XN-1000 was performed, and the scattergram abnormalities were then analyzed. There were 65 positive malaria samples as follows: P.falciparum (35%), P.vivax (60%), P.ovale (3.1%), and P.malariae (1.5%), but the species did not correlate with parasitemic index (p=0.691). Abnormalities of WDF and WNR scattergram were predominantly found than RET scattergram (80% vs. 27.7%). P.vivax predominantly caused abnormalities of the WDF and WNR scattergram in 36 of 39 samples (92.3%), whereas P.falciparum predominantly caused abnomalities of the RET scattergram in 14 of 23 samples (60.9%). There was 95% positivity of an abnormality in WDF/WNR/RET scattergram with a cut-off of > 5,0165.5/µL. There was correlation between WDF, WNR, RET scattergram detected by Sysmex XN-1000 and the parasitemia index.


2016 ◽  
Vol 23 (2) ◽  
Author(s):  
Awang Dyan Purnomo ◽  
Untung Tranggono

Objective: Urolithiasis could be caused by urinary tract infection (UTI). UTI in patients with urolithiasis need to be diagnose and manage as soon as possible. This study was aim to determine the diagnostic value of urinalysis examination to diagnose urinary tract infection (UTI) in patients with urolithiasis.Material & method: This study was an observational analytic with cross sectional study design, comparing one diagnostic tool with the gold standard tool to diagnose UTI. Total samples collected were 186 patients at Sardjito General Hospital, Yogyakarta. Urine culture and urinalysis were performed in patients with urinalysis and UTI. The results of urine culture and urinalysis were then compared by 2x2 table.Results: The sensitivity results on leukocyte esterase, eritrocyturia, bacteriuria, and nitrite respectively were 82.7%, 57.14%, 37.59%, and 13.53%. The specificity results on nitrite, bacteriuria, eritrocyturia, and leukocyte esterase respectively were 63.26%, 56.60%, 50.94%, and 33.96%. The highest level of accuracy was leukocyte esterase with 68.81% accuracy.Conclusion: This study showed that leukocyte esterase had good sensitivity with an accuracy of 68.81%. Examination of nitrite had the highest specificity compared to the other variables in urinalysis examination.


Author(s):  
G Sindhujha Sekar ◽  
A Esther Ruby ◽  
P Lalitha

Introduction: In perimenopausal age group particularly, 70% of all gynaecological consultations are for Abnormal Uterine Bleeding (AUB). About 30% of women seek medical assistance for AUB during their reproductive age group and about one third of hysterectomies are carried out for AUB alone. Aim: To determine the sensitivity, specificity, positive predictive value and negative predictive value of Transvaginal Ultrasonography (TVS) versus hysteroscopy in detecting uterine abnormalities Materials and Methods: A cross-sectional study in patients with AUB, admitted to the Department of Obstetrics and Gynaecology at RGGWCH, Puducherry between February 2016 and February 2017 who met the inclusion criteria were included. Sample size was 85 cases. After taking detailed history and physical examination the patient was investigated to rule out organic causes of AUB and then TVS and hysteroscopy were done. Any intrauterine pathology was looked for and endometrial sampling was taken from the abnormal sites for Histopathological Examination (HPE). Both TVS and hysteroscopy results were compared with histopathology which is the gold standard. Results: The sensitivity of TVS in diagnosis of uterine fibroid in comparison to hysteroscopy was 94.74% and the specificity was 71.21%. The sensitivity of hysteroscopy in diagnosis of endometrial hyperplasia in comparison to HPE was 75% and the specificity was 87.01%. The sensitivity of TVS in diagnosis of endometrial hyperplasia in comparison to HPE was 37.5% and the specificity was 90.91%. The sensitivity of hysteroscopy in diagnosis of polyp in comparison to HPE was 100% and the specificity was 97.3%. The sensitivity and specificity of TVS in diagnosis of polyp in comparison to HPE were 9.09% and 93.24%, respectively. Conclusion: TVS had a high sensitivity to detect fibroids but its value in detecting hyperplasia and polyps was in question in this study. But hysteroscopy had a maximum sensitivity to detect polyps and high sensitivity to detect endometrial hyperplasia compared to histopathology which is a gold standard investigation.


2021 ◽  
Vol 2021 ◽  
pp. 1-8
Author(s):  
Ziming Liu ◽  
Emmanuel Eric Pazo ◽  
Hong Ye ◽  
Cui Yu ◽  
Ling Xu ◽  
...  

Purpose. To assess the repeatability and agreement of refractive measurements using 2WIN-S photoscreening with the gold-standard cycloplegic retinoscope refraction. Design. Single centre, cross-sectional study. Methods. Spherical, cylindrical, axis, and spherical equivalent of 194 bilateral eyes of 97 children were assessed using a retinoscope and 2WIN-S. One week later, another operator repeated the 2WIN-S measurements. The primary outcome measures were to assess the repeatability and agreement between spherical equivalent, J0, and J45 readings of 2WIN-S. The repeatability of measurements was assessed by the within-subject standard deviation (2.77 Sw) and intraclass correlation coefficient (ICC). The agreement between devices was assessed using 95% limits of agreement. The extent of the agreement between cycloplegic retinoscopy and noncycloplegic 2WIN-S measurements was assessed using Bland–Altman analysis. Results. The mean age ± SD was 10.3 ± 2.46 year (range, 4–14 years). The sphere, cylinder, and spherical equivalent measurements were found to be consistent with both apparatus (r value >0.86). ICC for SE, J0, and J45 was 0.900, 0.666, and 0.639, respectively; Sw for SE, J0, and J45 was 0.61D, 0.30D, and 0.31D, respectively; Bland–Altman analysis of retinoscopy with cycloplegia and 2WIN-S for SE was 184/194 (95%) in 95% confidence interval, and the mean value was 0.46. J0 was 184/194 (95%), and the mean value is −0.04. J45 was 181/194 (93%), and the mean value is −0.15. Conclusion. The objective refractive measurement of 2WIN-S had good reliability and high agreement with the gold-standard retinoscopy refraction in children and adolescents. While consistency was observed, it is essential to take into consideration that it is a screening tool.


2021 ◽  
Author(s):  
Nida Zahid ◽  
Russell Seth Martins ◽  
Wajeeha Zahid ◽  
Wardah Khalid ◽  
Iqbal Azam ◽  
...  

2014 ◽  
Vol 48 (5) ◽  
pp. 957-967 ◽  
Author(s):  
Gail Macartney ◽  
Elizabeth VanDenKerkhof ◽  
Margaret B. Harrison ◽  
Dawn Stacey

Sign in / Sign up

Export Citation Format

Share Document