scholarly journals COMPARISON OF MOLECULAR AND SEROLOGICAL TESTS FOR SEVERE ACUTE RESPIRATORY SYNDROME CORONAVIRUS 2 (SARS-COV-2) IN POST-EXPOSURE EMPLOYEES OF THE NEPHROLOGY DEPARTMENT

2020 ◽  
Vol 73 (12) ◽  
pp. 2572-2575
Author(s):  
Marlena Kwiatkowska ◽  
Inga Chomicka ◽  
Jolanta Malyszko

Introduction: A novel coronavirus SARS-CoV-2 RNA, detected by reverse-transcription polymerase chain reaction (RT-PCR) was identified as the cause of a cluster of pneumonia cases in Wuhan, China. It rapidly spread, at first in China, then resulting in an epidemic in other countries throughout the world. One of such controversial topics is the issue of diagnostics and interpretation of test for COVID-19. According to Polish and global guidelines, the basis for diagnosis is molecular testing – real-time reverse transcriptasepolymerase chain reaction (RT-PCR). Taking all these data into consideration, the aim of the study was to compare RT-PCR with serological test in our employees post-exposure. According to Polish and global guidelines, the basis for diagnosis is molecular testing, real-time reverse transcriptase-polymerase chain reaction (RT-PCR). The aim: To compare RT-PCR with serological test in our employees post-exposure. Material and methods: 79 employees of the Clinic, 19 men and 60 women in the age range 27-69 years were evaluated. Tests were begun four days after information about the positive test in our „Employee 0” and lasted for 7 days. At first, we made RT-PCR tests on the specimen from nasopharyngeal swab. Then, we accomplished rapid antibodies tests. This test is based on the qualitative assessment of the presence of IgM and IgG antibodies by immunochromatography using a sample of capillary blood from the fingertip. Results: All the tests were negative. No employee developed symptoms during the 7-day follow-up after the end of the tests. Conclusions: As routine tests for patients have been implemented widely, but similar solutions for employees have not gained popularity. Use of personal protective equipment (PPE) e.g. facemask and shields, transparent screens, disposable medical uniforms, minimalization the contact time, increasing distance from both colleagues and patients (if possible), and strictly follow sanitary procedures largely contributed to the absence of illness in the surveyed group of employees.

2020 ◽  
Author(s):  
Angelo Virgilio Paradiso ◽  
Simona De Summa ◽  
Daniela Loconsole ◽  
Vito Procacci ◽  
Anna Sallustio ◽  
...  

BACKGROUND Real-time polymerase chain reaction (RT-PCR) testing for the identification of viral nucleic acid is the current standard for the diagnosis of SARS-CoV-2 infection, but technical issues limit its utilization for large-scale screening. Serological immunoglobulin M (IgM)/IgG testing has been proposed as a useful tool for detecting SARS-CoV-2 exposure. OBJECTIVE The objective of our study was to compare the results of the rapid serological VivaDiag test for SARS-CoV-2–related IgM/IgG detection with those of the standard RT-PCR laboratory test for identifying SARS-CoV-2 nucleic acid. METHODS We simultaneously performed both serological and molecular tests with a consecutive series of 191 symptomatic patients. The results provided by a new rapid serological colorimetric test for analyzing IgM/IgG expression were compared with those of RT-PCR testing for SARS-CoV-2 detection. RESULTS Of the 191 subjects, 70 (36.6%) tested positive for SARS-CoV-2 based on RT-PCR results, while 34 (17.3%) tested positive based on serological IgM/IgG expression. Additionally, 13 (6.8%) subjects tested positive based on serological test results, but also tested negative based on RT-PCR results. The rapid serological test had a sensitivity of 30% and a specificity of 89% compared to the standard RT-PCR assay. Interestingly, the performance of both assays improved 8 days after symptom appearance. After 10 days had passed since symptom appearance, the predictive value of the rapid serological test was higher than that of the standard molecular assay (proportion of positive results: 40% vs 20%). Multivariate analysis showed that age &gt;58 years <i>(P</i>&lt;.01) and period of &gt;15 days after symptom onset (<i>P</i>&lt;.02) were significant and independent factors associated with serological test positivity. CONCLUSIONS The rapid serological test analyzed in this study seems limited in terms of usefulness when diagnosing SARS-CoV-2 infection. However, it may be useful for providing relevant information on people’s immunoreaction to COVID-19 exposure.


10.2196/19152 ◽  
2020 ◽  
Vol 22 (10) ◽  
pp. e19152
Author(s):  
Angelo Virgilio Paradiso ◽  
Simona De Summa ◽  
Daniela Loconsole ◽  
Vito Procacci ◽  
Anna Sallustio ◽  
...  

Background Real-time polymerase chain reaction (RT-PCR) testing for the identification of viral nucleic acid is the current standard for the diagnosis of SARS-CoV-2 infection, but technical issues limit its utilization for large-scale screening. Serological immunoglobulin M (IgM)/IgG testing has been proposed as a useful tool for detecting SARS-CoV-2 exposure. Objective The objective of our study was to compare the results of the rapid serological VivaDiag test for SARS-CoV-2–related IgM/IgG detection with those of the standard RT-PCR laboratory test for identifying SARS-CoV-2 nucleic acid. Methods We simultaneously performed both serological and molecular tests with a consecutive series of 191 symptomatic patients. The results provided by a new rapid serological colorimetric test for analyzing IgM/IgG expression were compared with those of RT-PCR testing for SARS-CoV-2 detection. Results Of the 191 subjects, 70 (36.6%) tested positive for SARS-CoV-2 based on RT-PCR results, while 34 (17.3%) tested positive based on serological IgM/IgG expression. Additionally, 13 (6.8%) subjects tested positive based on serological test results, but also tested negative based on RT-PCR results. The rapid serological test had a sensitivity of 30% and a specificity of 89% compared to the standard RT-PCR assay. Interestingly, the performance of both assays improved 8 days after symptom appearance. After 10 days had passed since symptom appearance, the predictive value of the rapid serological test was higher than that of the standard molecular assay (proportion of positive results: 40% vs 20%). Multivariate analysis showed that age >58 years (P<.01) and period of >15 days after symptom onset (P<.02) were significant and independent factors associated with serological test positivity. Conclusions The rapid serological test analyzed in this study seems limited in terms of usefulness when diagnosing SARS-CoV-2 infection. However, it may be useful for providing relevant information on people’s immunoreaction to COVID-19 exposure.


2006 ◽  
Vol 175 (4S) ◽  
pp. 485-486
Author(s):  
Sabarinath B. Nair ◽  
Christodoulos Pipinikas ◽  
Roger Kirby ◽  
Nick Carter ◽  
Christiane Fenske

Author(s):  
Rajeev Kumar Jain ◽  
Nagaraj Perumal ◽  
Rakesh Shrivastava ◽  
Kamlesh Kumar Ahirwar ◽  
Jaya Lalwani ◽  
...  

Introduction: The whole world is facing an ongoing global health emergency of COVID-19 disease caused by the Severe Acute Respiratory Syndrome Coronavirus-2 (SARS-CoV-2). Real-Time Reverse Transcription-Polymerase Chain Reaction (RT-PCR) is a gold standard in the detection of SARS-CoV-2 infection. Presently, many single tube multiple gene target RT-PCR kits have been developed and are commercially available for Coronavirus Disease 2019 (COVID-19) diagnosis. Aim: To evaluate the performance of seven COVID-19 RT-PCR kits (DiagSure, Meril, VIRALDTECT II, TruPCR, Q-line, Allplex and TaqPath) which are commercially available for COVID-19 RT-PCR diagnosis. Materials and Methods: This observational study was conductedat the State Virology Laboratory (SVL), Gandhi Medical College, Bhopal, Madhya Pradesh, India. Seven commercially available kits have been evaluated on the basis of: (i) number of SARS-CoV-2 specific gene target; (ii) human housekeeping genes as internal control; (iii) RT-PCR run time; and (iv) kit performances to correctly detect SARS-CoV-2 positive and negative RNA samples. A total of 50 RNA samples (left over RNA) were included, master mix preparation, template addition and RT-PCR test has been performed according to kits literature. At the end of PCR run, mean and standard deviation of obtained cut-off of all kits were calculated using Microsoft Excel. Results: All seven RT-PCR kits performed satisfactory regarding the reproducibility and they could correctly identify 30 positive and 20 negative RNA samples. RNA samples (group C) having low viral loads with a high Cycle threshold (Ct) value (>30) were also detected by all these seven kits. Obtained Ct values of each group was in parallel range in comparison with the initial testing Ct values. Kits were found to be superior which contains primers and probes for three SARS-CoV-2 specific gene targets, have human housekeeping gene as internal control and taking less time to complete RT-PCR. Conclusion: All seven COVID-19 RT-PCR kits included in this study demonstrated satisfactory performance and can be used for the routine molecular diagnosis of COVID-19 disease.


2018 ◽  
Vol 6 (1) ◽  
pp. 2 ◽  
Author(s):  
David De la Torre ◽  
Claudete Astolfi-Ferreira ◽  
Ruy Chacon ◽  
Antonio Piantino Ferreira

Avian rotavirus A (ARtV-A) is a virus that affects young birds, causing acute diarrhea and economic losses in the poultry industry worldwide. The techniques used for the diagnosis of ARtV-A include electron microscopy, isolation in cell culture, and serology, as well as molecular techniques, such as the reverse transcription-polymerase chain reaction (RT-PCR). The objective of this work was to standardize a real-time RT-polymerase chain reaction (RT-qPCR) using SYBR Green chemistry for the rapid detection and quantification of ARtV-A from bird tissues and materials fixed on FTA cards on the basis of the nucleotide sequence of segment 6 (S6), which codes for the structural VP6 protein of ARtV-A. The results show the efficient amplification of the proposed target, with a limit of detection (LoD) of one copy gene (CG) per microliter of cDNA and a limit of quantification (LoQ) of 10 CGs per microliter. The efficiency of the primers was determined to be 95.66% using a standard curve, with an R2 value of 0.999 and a slope of −3.43. The specificity was determined using samples coinfected with ARtV-A, the chicken parvovirus, the chicken astrovirus, and the avian nephritis virus as positive controls and commercially available vaccines of the infectious bronchitis virus, infectious bursa disease virus, avian reovirus and healthy organs as negative controls. This technique, which lacks nonspecific PCR products and dimers, demonstrated greater sensitivity and specificity than conventional RT-PCR, and it reduced the analysis time by more than 50%.


Parasitology ◽  
2020 ◽  
Vol 147 (10) ◽  
pp. 1140-1148
Author(s):  
Fernanda do Carmo Magalhães ◽  
Samira Diniz Resende ◽  
Carolina Senra ◽  
Carlos Graeff-Teixeira ◽  
Martin Johannes Enk ◽  
...  

AbstractDue to the efforts to control schistosomiasis transmission in tropical countries, a large proportion of individuals from endemic areas present low parasite loads, which hinders diagnosis of intestinal schistosomiasis by the Kato-Katz (KK) method. Therefore, the development of more sensitive diagnostic methods is essential for efficient control measures. The aim was to evaluate the accuracy of a real-time polymerase chain reaction (RT-PCR) to detect Schistosoma mansoni DNA in fecal samples of individuals with low parasite loads. A cross-sectional population-based study was conducted in a rural community (n = 257) in Brazil. POC-CCA® was performed in urine and feces were used for RT-PCR. In addition, fecal exams were completed by 18 KK slides, saline gradient and Helmintex techniques. The combined results of the three parasitological tests detected schistosome eggs in 118 participants (45.9%) and composed the consolidated reference standard (CRS). By RT-PCR, 117 out of 215 tested samples were positive, showing 91.4% sensitivity, 80.2% specificity and good concordance with the CRS (kappa = 0.71). RT-PCR identified 86.9% of the individuals eliminating less than 12 eggs/g of feces, demonstrating much better performance than POC-CCA® (50.8%). Our results showed that RT-PCR is a valuable alternative for the diagnosis of intestinal schistosomiasis in individuals with very low parasite loads.


2009 ◽  
Vol 21 (5) ◽  
pp. 679-683 ◽  
Author(s):  
Pamela J. Ferro ◽  
Jason Osterstock ◽  
Bo Norby ◽  
Geoffrey T. Fosgate ◽  
Blanca Lupiani

As concerns over the global spread of highly pathogenic avian influenza H5N1 have heightened, more countries are faced with increased surveillance efforts and incident response planning for handling a potential outbreak. The incorporation of molecular techniques in most diagnostic laboratories has enabled fast and efficient testing of many agents of concern, including avian influenza. However, the need for high-throughput testing remains. In this study, the use of a 384–well format for high-throughput real-time reverse transcription polymerase chain reaction (real-time RT-PCR) testing for avian influenza is described. The analytical sensitivity of a real-time RT-PCR assay for avian influenza virus matrix gene with the use of both 96– and 384–well assay formats and serial dilutions of transcribed control RNA were comparable, resulting in similar limits of detection. Of 28 hunter-collected cloacal swabs that were positive by virus isolation, 26 (92.9%) and 27 (96.4%) were positive in the 96– and 384–well assays, respectively; of the 340 hunter-collected swabs that were negative by virus isolation, 45 (13.2%) and 23 (6.8%) were positive in the 96– and 384–well assays, respectively. The data presented herein supports the utility of the 384–well format in the event of an avian influenza outbreak for high-throughput real-time RT-PCR testing.


2006 ◽  
Vol 89 (5) ◽  
pp. 1335-1340
Author(s):  
Amir Abdulmawjood ◽  
Holger Schnenbrcher ◽  
Michael BÜlte

Abstract A collaborative trial was conducted to evaluate a real-time reverse transcriptase-polymerase chain reaction (RT-PCR) assay for detection of central nervous system (CNS) tissues in meat products (e.g., sausages). The method is based on the detection of ruminant glial fibrillary acidic protein (GFAP) mRNA by applying real-time RT-PCR. The assay was evaluated through a multicenter trial involving 12 participating laboratories that received coded cDNA obtained from 3 different types of sausages. The participants used 5 different real-time detection systems. The results obtained in this validation revealed that this real-time RT-PCR assay performed well in the different laboratories with a detection limit of at least 0.1% CNS in those test materials that contained strongly heat-treated samples (sausages cooked at 120C) and the medium heat-treated samples (sausages cooked at 80C). The detection limit of liver sausages was determined to be 0.2% of CNS. Neither the samples with no CNS additive nor the bovine DNA and the negative control containing 100% swine brain gave any positive signals. The presented results indicate that the real-time RT-PCR assay was just as reproducible between laboratories, as repeatable within a laboratory, could reliably be used for detection of bovine spongiform encephalopathy risk material in meat and meat products, and signify that it may be used with confidence in any laboratory.


2018 ◽  
Vol 57 (6) ◽  
pp. 688-693 ◽  
Author(s):  
Dominic Dizon ◽  
Marilyn Mitchell ◽  
Bernadette Dizon ◽  
Robert Libke ◽  
Michael W Peterson

AbstractCoccidioidomycosis, the fungal infection caused by dimorphic Coccidioides species, is typically diagnosed by histopathologic identification of spherules, by culture, or by serology. These tests are reliable but time-intensive, delaying diagnosis and treatment. Rapid real-time polymerase chain reaction (RT-PCR) can be performed and was validated to identify Coccidioides immitis using an in-house developed assay for the Becton Dickinson molecular instrument (BD MAXTM). These studies were performed using patient samples that had been shown to be positive on previously set up fungal cultures. To evaluate this new RT-PCR test in the clinical setting, we conducted a retrospective chart review of patients (N = 1160) who underwent Coccidioides PCR (Cocci PCR) on clinical samples between March 1, 2014, and Dec 31, 2016. We abstracted clinical, microbiologic, serologic, radiographic, treatment, and follow-up data. Specimens of cerebrospinal fluid (CSF), bronchioalveolar lavage fluid (BAL), lung tissue biopsy (LTB), sputum, and pleural fluid were evaluated to determine sensitivity and specificity. Of the 113 specimens that tested positive for Cocci PCR, all had clinical disease defined by traditional clinical criteria, yielding 100% specificity. Overall sensitivity was 74% versus 46% for fungal culture and was available in 4 hours rather than 1–2 weeks. Sensitivities varied by source material and clinical setting. CSF had a sensitivity of 59%, BAL for acute pneumonia 91%, sputum for acute pneumonia 94%, pleural fluid 86%, but LTB for lung nodules only 44%. Overall positive predictive value (PPV) was 100%, while negative predictive value (NPV) was 96%, but again this varied by specimen and clinical setting. Our experience with clinical testing of >1160 specimens over 2–3 years shows we can utilize this technology to improve our ability to diagnose disease but that the sensitivity varies by specimen source and clinical setting.


Sign in / Sign up

Export Citation Format

Share Document