Potential Benefits of an Integrated Electric-Acoustic Sound Processor with Children: A Preliminary Report

2017 ◽  
Vol 28 (02) ◽  
pp. 127-140 ◽  
Author(s):  
Jace Wolfe ◽  
Sara Neumann ◽  
Erin Schafer ◽  
Megan Marsh ◽  
Mark Wood ◽  
...  

Background: A number of published studies have demonstrated the benefits of electric-acoustic stimulation (EAS) over conventional electric stimulation for adults with functional low-frequency acoustic hearing and severe-to-profound high-frequency hearing loss. These benefits potentially include better speech recognition in quiet and in noise, better localization, improvements in sound quality, better music appreciation and aptitude, and better pitch recognition. There is, however, a paucity of published reports describing the potential benefits and limitations of EAS for children with functional low-frequency acoustic hearing and severe-to-profound high-frequency hearing loss. Purpose: The objective of this study was to explore the potential benefits of EAS for children. Research Design: A repeated measures design was used to evaluate performance differences obtained with EAS stimulation versus acoustic- and electric-only stimulation. Study Sample: Seven users of Cochlear Nucleus Hybrid, Nucleus 24 Freedom, CI512, and CI422 implants were included in the study. Data Collection and Analysis: Sentence recognition (assayed using the pediatric version of the AzBio sentence recognition test) was evaluated in quiet and at three fixed signal-to-noise ratios (SNR) (0, +5, and +10 dB). Functional hearing performance was also evaluated with the use of questionnaires, including the comparative version of the Speech, Spatial, and Qualities, the Listening Inventory for Education Revised, and the Children’s Home Inventory for Listening Difficulties. Results: Speech recognition in noise was typically better with EAS compared to participants’ performance with acoustic- and electric-only stimulation, particularly when evaluated at the less favorable SNR. Additionally, in real-world situations, children generally preferred to use EAS compared to electric-only stimulation. Also, the participants’ classroom teachers observed better hearing performance in the classroom with the use of EAS. Conclusions: Use of EAS provided better speech recognition in quiet and in noise when compared to performance obtained with use of acoustic- and electric-only stimulation, and children responded favorably to the use of EAS implemented in an integrated sound processor for real-world use.

2003 ◽  
Vol 14 (09) ◽  
pp. 525-533 ◽  
Author(s):  
Owen D. Murnane ◽  
John K. Kelly

Click-evoked otoacoustic emission (CEOAE) input/output (I/O) functions were measured in ears with normal hearing and in ears with sensorineural hearing loss above 2000 Hz. The low- to midfrequency CEOAEs obtained from the ears with high-frequency hearing loss were significantly reduced in level compared to the CEOAEs obtained from the ears with normal hearing even though there were no significant group differences in the 250–2000 Hz pure-tone thresholds. The findings are discussed within the context of two hypotheses that explain the low- to midfrequency reduction in transient-evoked otoacoustic emission (TEOAE) magnitude: (1) subclinical damage to the more apical regions of the cochlea not detected by behavioral audiometry, or (2) trauma to the basal region of the cochlea that affects the generation of low-frequency emissions. It is proposed that localized damage at basal cochlear sites affects the generation of low- to midfrequency CEOAE energy.


1984 ◽  
Vol 27 (4) ◽  
pp. 483-493 ◽  
Author(s):  
Sandra Gordon-Salant

The aim of this study was to assess the effect of low-frequency amplification on speech recognition performance by hearing-impaired listeners. Consonant identification performance by subjects with flat hearing losses and high-frequency hearing losses was assessed in three different hearing aid conditions, in quiet and noise. The experimental hearing aids all provided extra high-frequency amplification but differed in the amount of low-frequency amplification. The results showed that listeners with flat hearing losses benefited by low-frequency amplification, whereas subjects with high-frequency hearing losses exhibited deteriorating scores in conditions with greatest low-frequency amplification. Analyses of phonetic feature perception and individual consonant recognition scores revealed subtle interactions between hearing loss configuration and amplification contour.


1999 ◽  
Vol 8 (1) ◽  
pp. 47-56 ◽  
Author(s):  
Christopher W. Turner ◽  
Karolyn J. Cummings

This study investigated whether there are limitations on the benefit of providing audible speech information to listeners with high-frequency hearing loss. In a group of 10 listeners with various degrees of high-frequency hearing loss, speech recognition was tested across a wide range of presentation levels. For each of these listeners with hearing loss, recognition performance reached an asymptote of <100%. When the spectrum of the speech for this asymptotic performance level was compared with the listener's pure-tone thresholds, it was seen that providing audible speech to high-frequency regions (≥3000 Hz), where hearing loss exceeds 55 dB HL, tended to produce little or no improvement in recognition scores. In contrast, providing audible speech to lower frequency regions for a listener with a flat, severe-to-profound hearing loss did show improvement with increasing speech audibility, despite this listener's thresholds being greater than 55 dB HL. The present study adds further support to the idea that attempting to provide amplification to regions with severe high-frequency hearing loss (≥3000 Hz) may not necessarily benefit many individuals with hearing loss.


AAOHN Journal ◽  
1998 ◽  
Vol 46 (2) ◽  
pp. 67-75 ◽  
Author(s):  
Oi Saeng Hong ◽  
Shu-Pi C. Chen ◽  
Karen M. Conrad

The purposes of this study of airport workers were to a) determine the prevalence and symptoms of hearing loss, and b) identify compliance in using hearing protective devices (HPDs) and its relationship with hearing loss. This cross sectional epidemiological study was conducted with 255 noise exposed and 195 non-noise exposed, full time, male workers at a large metropolitan airport in Seoul, Korea. The three measures used were the self administered Occupational Hearing Questionnaire (OHQ), an audiological assessment, and a record review of baseline hearing and noise levels of locations in which the employee worked. The results showed a significant difference in prevalence of hearing loss (more than 25dB) between the noise and the non-noise exposed groups ( p < .05). About 60.8% of noise exposed workers reported continuous use of the HPDs. The continuous HPD users had significantly lower rates of hearing loss than the occasional users or non-users. The major symptom for workers with low frequency hearing loss was trouble in communication, whereas tinnitus and fullness in the ear were the most common symptoms for the workers with high frequency hearing loss. The airport workers exposed to excessive noise had a great deal of high frequency hearing loss. The degree of hearing loss present reinforces the need for aggressive hearing conservation programs among airport workers exposed to noise.


2017 ◽  
Vol 2017 ◽  
pp. 1-5 ◽  
Author(s):  
D. Graterol ◽  
C. Mir ◽  
C. Garcia-Vaquero ◽  
I. Braña ◽  
A. N. Pardo ◽  
...  

Background. Many drugs used for cancer chemotherapy produce reactive oxygen species, thus leading to various complications including nephrotoxicity, cardiotoxicity, and ototoxicity. Objective. We have provided a haplogroup analysis of a cohort of cancer patients treated with chemotherapy and compared factors associated with associated hearing loss. Study Design and Methods. This observational cohort study includes a pure-tone audiometry of the patients who underwent chemotherapeutic treatment. Medical history, presence of risk factors for hearing loss, toxic habits, and association with haplogroups have been determined. Results. 40% of patients developed hearing loss after administration of cisplatin, which was bilateral and symmetrical and of high frequencies. The most frequent haplogroup was H with a slight overexpression of groups V and K and a low frequency of groups J and T. No association of the haplogroup types with the hearing loss has been found; however age was revealed as an important determining factor. Conclusions. Ototoxicity caused by cisplatin is manifested as bilateral, symmetrical, and predominantly high frequency hearing loss. Although we did not find a strong correlation of haplogroups with ototoxicity, our results revealed the existence of a risk group of elderly patients over 60, which are more susceptible to hearing loss induced by cisplatin, than young adults, regardless of preexisting hearing loss.


2014 ◽  
Vol 25 (10) ◽  
pp. 1022-1033 ◽  
Author(s):  
Andrew John ◽  
Jace Wolfe ◽  
Susan Scollie ◽  
Erin Schafer ◽  
Mary Hudson ◽  
...  

Background: Previous research has suggested that use of nonlinear frequency compression (NLFC) can improve audibility for high-frequency sounds and speech recognition of children with moderate to profound high-frequency hearing loss. Furthermore, previous studies have generally found no detriment associated with the use of NLFC. However, there have been no published studies examining the effect of NLFC on the performance of children with cookie-bite audiometric configurations. For this configuration of hearing loss, frequency-lowering processing will likely move high-frequency sounds to a lower frequency range at which a greater degree of hearing loss exists. Purpose: The purpose of this study was to evaluate and compare the effects of wideband amplification and NLFC on high-frequency audibility and speech recognition of children with cookie-bite audiometric configurations. Research Design: This study consisted of a within-participant design with repeated measures across test conditions. Study Sample: Seven children, ages 6–13 yr, with cookie-bite audiometric configurations and normal hearing or mild hearing loss at 6000 and 8000 Hz, were recruited. Intervention: Participants were fitted with Phonak Nios S H2O III behind-the-ear hearing aids and Oticon Safari 300 behind-the-ear hearing aids. Data Collection: The participants were evaluated after three 4-to 6-wk intervals: (1) Phonak Nios S H2O III without NLFC, (2) Phonak Nios S H2O III with NLFC, and (3) Oticon Safari 300 with wideband frequency response extending to 8000 Hz. The order in which each technology was used was counterbalanced across participants. High-frequency audibility was evaluated by assessing aided thresholds (dB SPL) for warble tones and the high-frequency phonemes /sh/ and /s/. Speech recognition in quiet was measured with the University of Western Ontario (UWO) Plurals Test, the UWO Distinctive Features Difference (DFD) Test, and the Phoneme Perception Test vowel-consonant-vowel nonsense syllable test. Sentence recognition in noise was evaluated with the Bamford-Kowal-Bench Speech-In-Noise (BKB-SIN) Test. Analysis: Repeated-measures analyses of variance were used to analyze the data collected in this study. The results across the three different conditions were compared. Results: No difference in performance across conditions was observed for detection of high-frequency warble tones and the speech sounds /sh/ and /s/. No significant difference was seen across conditions for speech recognition in quiet when measured with the UWO Plurals Test, the UWO-DFD Test, and the Phoneme Perception Test vowel-consonant-vowel nonsense syllable test. Finally, there were also no differences across conditions on the BKB-SIN Test. Conclusions: These results suggest that NLFC does not degrade or improve audibility for and recognition of high-frequency speech sounds as well as sentence recognition in noise when compared with wideband amplification for children with cookie-bite audiometric configurations.


2002 ◽  
Vol 13 (07) ◽  
pp. 356-366
Author(s):  
Therese C. Walden ◽  
Brian E. Walden ◽  
Mary T. Cord

This study compared the real-ear response provided by custom-fit hearing aids to the closest matching fixed-format disposable hearing aids in patients with precipitous high-frequency hearing loss. Laboratory and field measures of aided performance were obtained to compare patient performance with the custom-fit and fixed-format hearing aids. In addition, coupler versus real-ear response differences were compared for the two hearing aid types. The results revealed that relatively close approximations to the real-ear aided responses of the custom-fit instruments were possible for most participants using seven fixed acoustic formats. No significant differences in mean performance between the two instrument types were observed for aided speech recognition or field ratings of aided performance, although mean patient satisfaction was lower for the disposable hearing aids. The real-ear to coupler difference was greater for the disposable hearing aid than for the custom-fit instruments, presumably owing to its deeper insertion into the ear canal.


Sign in / Sign up

Export Citation Format

Share Document