Sound Quality Measures for Speech in Noise through a Commercial Hearing Aid Implementing "Digital Noise Reduction"

2005 ◽  
Vol 16 (05) ◽  
pp. 270-277 ◽  
Author(s):  
Todd A. Ricketts ◽  
Benjamin W.Y. Hornsby

This brief report discusses the affect of digital noise reduction (DNR) processing on aided speech recognition and sound quality measures in 14 adults fitted with a commercial hearing aid. Measures of speech recognition and sound quality were obtained in two different speech-in-noise conditions (71 dBA speech, +6 dB SNR and 75 dBA speech, +1 dB SNR). The results revealed that the presence or absence of DNR processing did not impact speech recognition in noise (either positively or negatively). Paired comparisons of sound quality for the same speech in noise signals, however, revealed a strong preference for DNR processing. These data suggest that at least one implementation of DNR processing is capable of providing improved sound quality, for speech in noise, in the absence of improved speech recognition.

2016 ◽  
Vol 27 (03) ◽  
pp. 237-251 ◽  
Author(s):  
Susan Scollie ◽  
Charla Levy ◽  
Nazanin Pourmand ◽  
Parvaneh Abbasalipour ◽  
Marlene Bagatto ◽  
...  

Background: Although guidelines for fitting hearing aids for children are well developed and have strong basis in evidence, specific protocols for fitting and verifying some technologies are not always available. One such technology is noise management in children’s hearing aids. Children are frequently in high-level and/or noisy environments, and many options for noise management exist in modern hearing aids. Verification protocols are needed to define specific test signals and levels for use in clinical practice. Purpose: This work aims to (1) describe the variation in different brands of noise reduction processors in hearing aids and the verification of these processors and (2) determine whether these differences are perceived by 13 children who have hearing loss. Finally, we aimed to develop a verification protocol for use in pediatric clinical practice. Study Sample: A set of hearing aids was tested using both clinically available test systems and a reference system, so that the impacts of noise reduction signal processing in hearing aids could be characterized for speech in a variety of background noises. A second set of hearing aids was tested across a range of audiograms and across two clinical verification systems to characterize the variance in clinical verification measurements. Finally, a set of hearing aid recordings that varied by type of noise reduction was rated for sound quality by children with hearing loss. Results: Significant variation across makes and models of hearing aids was observed in both the speed of noise reduction activation and the magnitude of noise reduction. Reference measures indicate that noise-only testing may overestimate noise reduction magnitude compared to speech-in-noise testing. Variation across clinical test signals was also observed, indicating that some test signals may be more successful than others for characterization of hearing aid noise reduction. Children provided different sound quality ratings across hearing aids, and for one hearing aid rated the sound quality as higher with the noise reduction system activated. Conclusions: Implications for clinical verification systems may be that greater standardization and the use of speech-in-noise test signals may improve the quality and consistency of noise reduction verification cross clinics. A suggested clinical protocol for verification of noise management in children’s hearing aids is suggested.


2002 ◽  
Vol 116 (S28) ◽  
pp. 47-51 ◽  
Author(s):  
Sunil N. Dutt ◽  
Ann-Louise McDermott ◽  
Stuart P. Burrell ◽  
Huw R. Cooper ◽  
Andrew P. Reid ◽  
...  

The Birmingham bone-anchored hearing aid (BAHA) programme, since its inception in 1988, has fitted more than 300 patients with unilateral bone-anchored hearing aids. Recently, some of the patients who benefited extremely well with unilateral aids applied for bilateral amplification. To date, 15 patients have been fitted with bilateral BAHAs. The benefits of bilateral amplification have been compared to unilateral amplification in 11 of these patients who have used their second BAHA for 12 months or longer. Following a subjective analysis in the form of comprehensive questionnaires, objective testing was undertaken to assess specific issues such as ‘speech recognition in quiet’, ‘speech recognition in noise’ and a modified ‘speech-in-simulated-party-noise’ (Plomp) test.‘Speech in quiet’ testing revealed a 100 per cent score with both unilateral and bilateral BAHAs. With ‘speech in noise’ all 11 patients scored marginally better with bilateral aids compared to best unilateral responses. The modified Plomp test demonstrated that bilateral BAHAs provided maximum flexibility when the origin of noise cannot be controlled as in day-to-day situations. In this small case series the results are positive and are comparable to the experience of the Nijmegen BAHA group.


2012 ◽  
Vol 23 (08) ◽  
pp. 577-589 ◽  
Author(s):  
Mary Rudner ◽  
Thomas Lunner ◽  
Thomas Behrens ◽  
Elisabet Sundewall Thorén ◽  
Jerker Rönnberg

Background: Recently there has been interest in using subjective ratings as a measure of perceived effort during speech recognition in noise. Perceived effort may be an indicator of cognitive load. Thus, subjective effort ratings during speech recognition in noise may covary both with signal-to-noise ratio (SNR) and individual cognitive capacity. Purpose: The present study investigated the relation between subjective ratings of the effort involved in listening to speech in noise, speech recognition performance, and individual working memory (WM) capacity in hearing impaired hearing aid users. Research Design: In two experiments, participants with hearing loss rated perceived effort during aided speech perception in noise. Noise type and SNR were manipulated in both experiments, and in the second experiment hearing aid compression release settings were also manipulated. Speech recognition performance was measured along with WM capacity. Study Sample: There were 46 participants in all with bilateral mild to moderate sloping hearing loss. In Experiment 1 there were 16 native Danish speakers (eight women and eight men) with a mean age of 63.5 yr (SD = 12.1) and average pure tone (PT) threshold of 47. 6 dB (SD = 9.8). In Experiment 2 there were 30 native Swedish speakers (19 women and 11 men) with a mean age of 70 yr (SD = 7.8) and average PT threshold of 45.8 dB (SD = 6.6). Data Collection and Analysis: A visual analog scale (VAS) was used for effort rating in both experiments. In Experiment 1, effort was rated at individually adapted SNRs while in Experiment 2 it was rated at fixed SNRs. Speech recognition in noise performance was measured using adaptive procedures in both experiments with Dantale II sentences in Experiment 1 and Hagerman sentences in Experiment 2. WM capacity was measured using a letter-monitoring task in Experiment 1 and the reading span task in Experiment 2. Results: In both experiments, there was a strong and significant relation between rated effort and SNR that was independent of individual WM capacity, whereas the relation between rated effort and noise type seemed to be influenced by individual WM capacity. Experiment 2 showed that hearing aid compression setting influenced rated effort. Conclusions: Subjective ratings of the effort involved in speech recognition in noise reflect SNRs, and individual cognitive capacity seems to influence relative rating of noise type.


2018 ◽  
Author(s):  
Tim Schoof ◽  
Pamela Souza

Objective: Older hearing-impaired adults typically experience difficulties understanding speech in noise. Most hearing aids address this issue using digital noise reduction. While noise reduction does not necessarily improve speech recognition, it may reduce the resources required to process the speech signal. Those available resources may, in turn, aid the ability to perform another task while listening to speech (i.e., multitasking). This study examined to what extent changing the strength of digital noise reduction in hearing aids affects the ability to multitask. Design: Multitasking was measured using a dual-task paradigm, combining a speech recognition task and a visual monitoring task. The speech recognition task involved sentence recognition in the presence of six-talker babble at signal-to-noise ratios (SNRs) of 2 and 7 dB. Participants were fit with commercially-available hearing aids programmed under three noise reduction settings: off, mild, strong. Study sample: 18 hearing-impaired older adults. Results: There were no effects of noise reduction on the ability to multitask, or on the ability to recognize speech in noise. Conclusions: Adjustment of noise reduction settings in the clinic may not invariably improve performance for some tasks.


2012 ◽  
Vol 23 (08) ◽  
pp. 606-615 ◽  
Author(s):  
HaiHong Liu ◽  
Hua Zhang ◽  
Ruth A. Bentler ◽  
Demin Han ◽  
Luo Zhang

Background: Transient noise can be disruptive for people wearing hearing aids. Ideally, the transient noise should be detected and controlled by the signal processor without disrupting speech and other intended input signals. A technology for detecting and controlling transient noises in hearing aids was evaluated in this study. Purpose: The purpose of this study was to evaluate the effectiveness of a transient noise reduction strategy on various transient noises and to determine whether the strategy has a negative impact on sound quality of intended speech inputs. Research Design: This was a quasi-experimental study. The study involved 24 hearing aid users. Each participant was asked to rate the parameters of speech clarity, transient noise loudness, and overall impression for speech stimuli under the algorithm-on and algorithm-off conditions. During the evaluation, three types of stimuli were used: transient noises, speech, and background noises. The transient noises included “knife on a ceramic board,” “mug on a tabletop,” “office door slamming,” “car door slamming,” and “pen tapping on countertop.” The speech sentences used for the test were presented by a male speaker in Mandarin. The background noises included “party noise” and “traffic noise.” All of these sounds were combined into five listening situations: (1) speech only, (2) transient noise only, (3) speech and transient noise, (4) background noise and transient noise, and (5) speech and background noise and transient noise. Results: There was no significant difference on the ratings of speech clarity between the algorithm-on and algorithm-off (t-test, p = 0.103). Further analysis revealed that speech clarity was significant better at 70 dB SLP than 55 dB SPL (p < 0.001). For transient noise loudness: under the algorithm-off condition, the percentages of subjects rating the transient noise to be somewhat soft, appropriate, somewhat loud, and too loud were 0.2, 47.1, 29.6, and 23.1%, respectively. The corresponding percentages under the algorithm-on were 3.0, 72.6, 22.9, and 1.4%, respectively. A significant difference on the ratings of the transient noise loudness was found between the algorithm-on and algorithm-off (t-test, p < 0.001). For overall impression for speech stimuli: under the algorithm-off condition, the percentage of subjects rating the algorithm to be not helpful at all, somewhat helpful, helpful, and very helpful for speech stimuli were 36.5, 20.8, 33.9, and 8.9%, respectively. Under the algorithm-on condition, the corresponding percentages were 35.0, 19.3, 30.7, and 15.0%, respectively. Statistical analysis revealed there was a significant difference on the ratings of overall impression on speech stimuli. The ratings under the algorithm-on condition were significantly more helpful for speech understanding than the ratings under algorithm-off (t-test, p < 0.001). Conclusions: The transient noise reduction strategy appropriately controlled the loudness for most of the transient noises and did not affect the sound quality, which could be beneficial to hearing aid wearers.


2021 ◽  
Vol 32 (08) ◽  
pp. 478-486
Author(s):  
Lisa G. Potts ◽  
Soo Jang ◽  
Cory L. Hillis

Abstract Background For cochlear implant (CI) recipients, speech recognition in noise is consistently poorer compared with recognition in quiet. Directional processing improves performance in noise and can be automatically activated based on acoustic scene analysis. The use of adaptive directionality with CI recipients is new and has not been investigated thoroughly, especially utilizing the recipients' preferred everyday signal processing, dynamic range, and/or noise reduction. Purpose This study utilized CI recipients' preferred everyday signal processing to evaluate four directional microphone options in a noisy environment to determine which option provides the best speech recognition in noise. A greater understanding of automatic directionality could ultimately improve CI recipients' speech-in-noise performance and better guide clinicians in programming. Study Sample Twenty-six unilateral and seven bilateral CI recipients with a mean age of 66 years and approximately 4 years of CI experience were included. Data Collection and Analysis Speech-in-noise performance was measured using eight loudspeakers in a 360-degree array with HINT sentences presented in restaurant noise. Four directional options were evaluated (automatic [SCAN], adaptive [Beam], fixed [Zoom], and Omni-directional) with participants' everyday use signal processing options active. A mixed-model analysis of variance (ANOVA) and pairwise comparisons were performed. Results Automatic directionality (SCAN) resulted in the best speech-in-noise performance, although not significantly better than Beam. Omni-directional performance was significantly poorer compared with the three other directional options. A varied number of participants performed their best with each of the four-directional options, with 16 performing best with automatic directionality. The majority of participants did not perform best with their everyday directional option. Conclusion The individual variability seen in this study suggests that CI recipients try with different directional options to find their ideal program. However, based on a CI recipient's motivation to try different programs, automatic directionality is an appropriate everyday processing option.


Author(s):  
Bruna S. Mussoi

Purpose Music training has been proposed as a possible tool for auditory training in older adults, as it may improve both auditory and cognitive skills. However, the evidence to support such benefits is mixed. The goal of this study was to determine the differential effects of lifelong musical training and working memory on speech recognition in noise, in older adults. Method A total of 31 musicians and nonmusicians aged 65–78 years took part in this cross-sectional study. Participants had a normal pure-tone average, with most having high-frequency hearing loss. Working memory (memory capacity) was assessed with the backward Digit Span test, and speech recognition in noise was assessed with three clinical tests (Quick Speech in Noise, Hearing in Noise Test, and Revised Speech Perception in Noise). Results Findings from this sample of older adults indicate that neither music training nor working memory was associated with differences on the speech recognition in noise measures used in this study. Similarly, duration of music training was not associated with speech-in-noise recognition. Conclusions Results from this study do not support the hypothesis that lifelong music training benefits speech recognition in noise. Similarly, an effect of working memory (memory capacity) was not apparent. While these findings may be related to the relatively small sample size, results across previous studies that investigated these effects have also been mixed. Prospective randomized music training studies may be able to better control for variability in outcomes associated with pre-existing and music training factors, as well as to examine the differential impact of music training and working memory for speech-in-noise recognition in older adults.


2012 ◽  
Vol 23 (03) ◽  
pp. 171-181 ◽  
Author(s):  
Rachel A. McArdle ◽  
Mead Killion ◽  
Monica A. Mennite ◽  
Theresa H. Chisolm

Background: The decision to fit one or two hearing aids in individuals with binaural hearing loss has been debated for years. Although some 78% of U.S. hearing aid fittings are binaural (Kochkin , 2010), Walden and Walden (2005) presented data showing that 82% (23 of 28 patients) of their sample obtained significantly better speech recognition in noise scores when wearing one hearing aid as opposed to two. Purpose: To conduct two new experiments to fuel the monaural/binaural debate. The first experiment was a replication of Walden and Walden (2005), whereas the second experiment examined the use of binaural cues to improve speech recognition in noise. Research Design: A repeated measures experimental design. Study Sample: Twenty veterans (aged 59–85 yr), with mild to moderately severe binaurally symmetrical hearing loss who wore binaural hearing aids were recruited from the Audiology Department at the Bay Pines VA Healthcare System. Data Collection and Analysis: Experiment 1 followed the procedures of the Walden and Walden study, where signal-to-noise ratio (SNR) loss was measured using the Quick Speech-in-Noise (QuickSIN) test on participants who were aided with their current hearing aids. Signal and noise were presented in the sound booth at 0° azimuth under five test conditions: (1) right ear aided, (2) left ear aided, (3) both ears aided, (4) right ear aided, left ear plugged, and (5) unaided. The opposite ear in (1) and (2) was left open. In Experiment 2, binaural Knowles Electronics Manikin for Acoustic Research (KEMAR) manikin recordings made in Lou Malnati's pizza restaurant during a busy period provided a typical real-world noise, while prerecorded target sentences were presented through a small loudspeaker located in front of the KEMAR manikin. Subjects listened to the resulting binaural recordings through insert earphones under the following four conditions: (1) binaural, (2) diotic, (3) monaural left, and (4) monaural right. Results: Results of repeated measures ANOVAs demonstrated that the best speech recognition in noise performance was obtained by most participants with both ears aided in Experiment 1 and in the binaural condition in Experiment 2. Conclusions: In both experiments, only 20% of our subjects did better in noise with a single ear, roughly similar to the earlier Jerger et al (1993) finding that 8–10% of elderly hearing aid users preferred one hearing aid.


Sign in / Sign up

Export Citation Format

Share Document