Phase-Resolved CARS Temperature Measurement in a Lean Premixed Gas Turbine Combustor (II) -Effect of Equivalence Ratio on Phase-Resolved Gas Temperature-

2004 ◽  
Vol 28 (10) ◽  
pp. 1193-1201
Author(s):  
Jong Ho Lee ◽  
Chung Hwan Jeon ◽  
Chul Woong Park ◽  
Jae Won Hahn ◽  
Young June Chang
2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Kirubakaran V. ◽  
Naren Shankar R.

Purpose This paper aims to predict the effect of combustor inlet area ratio (CIAR) on the lean blowout limit (LBO) of a swirl stabilized can-type micro gas turbine combustor having a thermal capacity of 3 kW. Design/methodology/approach The blowout limits of the combustor were predicted predominantly from numerical simulations by using the average exit gas temperature (AEGT) method. In this method, the blowout limit is determined from characteristics of the average exit gas temperature of the combustion products for varying equivalence. The CIAR value considered in this study ranges from 0.2 to 0.4 and combustor inlet velocities range from 1.70 to 6.80 m/s. Findings The LBO equivalence ratio decreases gradually with an increase in inlet velocity. On the other hand, the LBO equivalence ratio decreases significantly especially at low inlet velocities with a decrease in CIAR. These results were backed by experimental results for a case of CIAR equal to 0.2. Practical implications Gas turbine combustors are vulnerable to operate on lean equivalence ratios at cruise flight to avoid high thermal stresses. A flame blowout is the main issue faced in lean operations. Based on literature and studies, the combustor lean blowout performance significantly depends on the primary zone mass flow rate. By incorporating variable area snout in the combustor will alter the primary zone mass flow rates by which the combustor will experience extended lean blowout limit characteristics. Originality/value This is a first effort to predict the lean blowout performance on the variation of combustor inlet area ratio on gas turbine combustor. This would help to extend the flame stability region for the gas turbine combustor.


Author(s):  
Hyung Ju Lee ◽  
Kyu Tae Kim ◽  
Jong Guen Lee ◽  
Bryan D. Quay ◽  
Domenic A. Santavicca

An experimental study was conducted to estimate and confirm equivalence ratio fluctuations at the inlet of a lean premixed gas turbine combustor. Fuel injectors were placed at several locations in the mixing section of the combustor, in order to produce different instability characteristics due to the equivalence ratio fluctuations. An IR absorption technique was used to measure the equivalence ratio fluctuations at the inlet of the dump combustor. The measured IR signals were processed in two different ways and the results were compared to confirm the two calibrated equivalence ratio signals. The processed data showed that the two processing methods gave very similar results, and the phase of the measured equivalence ratio fluctuations at the combustor inlet by the IR absorption technique agreed well with that of equivalence ratio fluctuations predicted by time lags in the mixing section. It was, however, not possible to accurately predict the magnitude of the equivalence ratio fluctuations at the combustor inlet by the time lag analysis because the equivalence ratio fluctuations generataed at the fuel injection location is changed by mixing and diffusion as the fuel is convected through the combustor.


Author(s):  
Hyung Ju Lee ◽  
Kyu Tae Kim ◽  
Jong Guen Lee ◽  
Bryan D. Quay ◽  
Domenic A. Santavicca

An experimental study was conducted to characterize the combined effects of flame-vortex interactions and equivalence ratio fluctuations on self-excited combustion instabilities in a swirl-stabilized lean premixed gas turbine combustor. The combustor was designed so that the fuel injector location and the combustion chamber length could be independently varied. In addition, the fuel and air could be mixed upstream of the choked inlet to the combustor, thereby eliminating the possibility of equivalence ratio fluctuations. Experiments were performed over a broad range of operating conditions and at each condition both the combustor length and the fuel injection location were varied. Dynamic pressure in the combustor, acoustic pressure and velocity in the mixing section, and the overall rate of heat release were simultaneously measured at all operating conditions. Two distinct instability regimes were observed; one near 220 Hz and the other near 345 Hz. It was also found that the strength of the instability changed significantly as the fuel injection location was varied, while the phase of the acoustic pressure and velocity fluctuations in the mixing section did not change. A time series of pressure and CH* chemiluminescence signals confirmed constructive or destructive coupling of the two instability mechanisms; the flame-vortex interaction and the equivalence ratio fluctuation interact each other and determine the instability characteristics in partially premixed conditions.


2021 ◽  
Vol 35 (8) ◽  
pp. 6776-6784
Author(s):  
Truc Huu Nguyen ◽  
Jungkyu Park ◽  
Changhun Sin ◽  
Seungchai Jung ◽  
Shaun Kim

Author(s):  
Brian Jones ◽  
Jong Guen Lee ◽  
Bryan D. Quay ◽  
Domenic A. Santavicca

The response of turbulent premixed flames to inlet velocity fluctuations is studied experimentally in a lean premixed, swirl-stabilized, gas turbine combustor. Overall chemiluminescence intensity is used as a measure of the fluctuations in the flame’s global heat release rate, and hot wire anemometry is used to measure the inlet velocity fluctuations. Tests are conducted over a range of mean inlet velocities, equivalence ratios, and velocity fluctuation frequencies, while the normalized inlet velocity fluctuation (V′/Vmean) is fixed at 5% to ensure linear flame response over the employed modulation frequency range. The measurements are used to calculate a flame transfer function relating the velocity fluctuation to the heat release fluctuation as a function of the velocity fluctuation frequency. At low frequency, the gain of the flame transfer function increases with increasing frequency to a peak value greater than 1. As the frequency is further increased, the gain decreases to a minimum value, followed by a second smaller peak. The frequencies at which the gain is minimum and achieves its second peak are found to depend on the convection time scale and the flame’s characteristic length scale. Phase-synchronized CH∗ chemiluminescence imaging is used to characterize the flame’s response to inlet velocity fluctuations. The observed flame response can be explained in terms of the interaction of two flame perturbation mechanisms, one originating at flame-anchoring point and propagating along the flame front and the other from vorticity field generated in the outer shear layer in the annular mixing section. An analysis of the phase-synchronized flame images show that when both perturbations arrive at the flame at the same time (or phase), they constructively interfere, producing the second peak observed in the gain curves. When the perturbations arrive at the flame 180 degrees out-of-phase, they destructively interfere, producing the observed minimum in the gain curve.


Author(s):  
Candy Hernandez ◽  
Vincent McDonell

Abstract Lean-premixed (LPM) gas turbines have been developed for stationary power generation in efforts to reduce emissions due to strict air quality standards. Lean-premixed operation is beneficial as it reduces combustor temperatures, thus decreasing NOx formation and unburned hydrocarbons. However, tradeoffs occur between system performance and turbine emissions. Efforts to minimize tradeoffs between stability and emissions include the addition of hydrogen to natural gas, a common fuel used in stationary gas turbines. The addition of hydrogen is promising for both increasing combustor stability and further reducing emissions because of its wide flammability limits allowing for lower temperature operation, and lack of carbon molecules. Other efforts to increase gas turbine stability include the usage of a non-lean pilot flame to assist in stabilizing the main flame. By varying fuel composition for both the main and piloted flows of a gas turbine combustor, the effect of hydrogen addition on performance and emissions can be systematically evaluated. In the present work, computational fluid dynamics (CFD) and chemical reactor networks (CRN) are created to evaluate stability (LBO) and emissions of a gas turbine combustor by utilizing fuel and flow rate conditions from former hydrogen and natural gas experimental results. With CFD and CRN analysis, the optimization of parameters between fuel composition and main/pilot flow splits can provide feedback for minimizing pollutants while increasing stability limits. The results from both the gas turbine model and former experimental results can guide future gas turbine operation and design.