scholarly journals The Lung and Soft Tissue Stopping Power Estimates for a Modified Phantom Using MCNPX

Author(s):  
Olaseni M. Bello ◽  
Wan Mohammad S. Wan Hassan ◽  
Norehan M. Nor

The Adult Male® and Adult Female® phantoms of ORNL were modified with Ir-192 source and additional tally cards from the MCNP® data library. The lung and eleven soft tissues were used for the study. The soft tissues include Liver, Stomach, Ovaries, Testes, Brain, Thyroid, Kidney, Pancreas, Gall Bladder, Heart, and the Small Intestine. The computational simulation was achieved using MCNPX with nps of 107 , and the data set of the lung and soft tissues derived for Malaysian population [14]. The relative error, R was <0.05 for F4 and the F6 tallies across the energy range studied. The results obtained for 0.1-10.0 MeV energies for the F4 and F6 tallies were used to estimate the mass stopping power, S/ρ (MeVg1 cm2 ) and the linear stopping power, S (MeV/cm). The result compares favorably among the tissues. This result is very relevant and useful in validating an on-going lung and soft tissue model construction

Author(s):  
Sebastian Halm ◽  
David Haberthür ◽  
Elisabeth Eppler ◽  
Valentin Djonov ◽  
Andreas Arnold

Abstract Introduction This pilot study explores whether a human Thiel-embalmed temporal bone is suitable for generating an accurate and complete data set with micro-computed tomography (micro-CT) and whether solid iodine-staining improves visualization and facilitates segmentation of middle ear structures. Methods A temporal bone was used to verify the accuracy of the imaging by first digitally measuring the stapes on the tomography images and then physically under the microscope after removal from the temporal bone. All measurements were compared with literature values. The contralateral temporal bone was used to evaluate segmentation and three-dimensional (3D) modeling after iodine staining and micro-CT scanning. Results The digital and physical stapes measurements differed by 0.01–0.17 mm or 1–19%, respectively, but correlated well with the literature values. Soft tissue structures were visible in the unstained scan. However, iodine staining increased the contrast-to-noise ratio by a factor of 3.7 on average. The 3D model depicts all ossicles and soft tissue structures in detail, including the chorda tympani, which was not visible in the unstained scan. Conclusions Micro-CT imaging of a Thiel-embalmed temporal bone accurately represented the entire anatomy. Iodine staining considerably increased the contrast of soft tissues, simplified segmentation and enabled detailed 3D modeling of the middle ear.


Author(s):  
Salina Sulaiman ◽  
Tan Sing Yee ◽  
Abdullah Bade

Physically based models assimilate organ-specific material properties, thus they are suitable in developing a surgical simulation. This study uses mass spring model (MSM) to represent the human liver because MSM is a discrete model that is potentially more realistic than the finite element model (FEM). For a high-end computer aided medical technology such as the surgical simulator, the most important issues are to fulfil the basic requirement of a surgical simulator. Novice and experienced surgeons use surgical simulator for surgery training and planning. Therefore, surgical simulation must provide a realistic and fast responding virtual environment. This study focuses on fulfilling the time complexity and realistic of the surgical simulator. In order to have a fast responding simulation, the choice of numerical integration method is crucial. This study shows that MATLAB ode45 is the fastest method compared to 2nd ordered Euler, MATLAB ode113, MATLAB ode23s and MATLAB ode23t. However, the major issue is human liver consists of soft tissues. In modelling a soft tissue model, we need to understand the mechanical response of soft tissues to surgical manipulation. Any interaction between haptic device and the liver model may causes large deformation and topology change in the soft tissue model. Thus, this study investigates and presents the effect of varying mass, damping, stiffness coefficient on the nonlinear liver mass spring model. MATLAB performs and shows simulation results for each of the experiment. Additionally, the observed optimal dataset of liver behaviour is applied in SOFA (Simulation Open Framework Architecture) to visualize the major effect.


2020 ◽  
Vol 64 (1-4) ◽  
pp. 1253-1259
Author(s):  
Minghui Wang ◽  
Hongliu Yu

Clamping devices with constant force or pressure are desired in medical device, such as hemostatic forceps and the artificial sphincter, to prevent soft tissues from injures due to overloading. It is easily obtained by stretching an SMA wire. However, studies with SMA bending round bar have seldom been reported before. This paper studied constant force characteristic of C-shaped round bar with shape memory alloys. Optimization designs of the components were carried out with computational simulation. Numerical results show that the phenomenon of constant force strongly depends on contour curve shape and geometric dimensions of the C-shaped round bar of SMA component.


Author(s):  
Filippo Boriani ◽  
Edoardo Raposio ◽  
Costantino Errani

: Musculoskeletal tumors of the hand are a rare entity and are divided into skeletal and soft tissue tumors. Either category comprises benign and malignant or even intermediate tumors. Basic radiology allows an optimal resolution of bone and related soft tissue areas, ultrasound and more sophisticated radiologic tools such as scintigraphy, CT and MRI allow a more accurate evaluation of tumor extent. Enchondroma is the most common benign tumor affecting bone, whereas chondrosarcoma is the most commonly represented malignant neoplasm localized to hand bones. In the soft tissues ganglions are the most common benign tumors and epithelioid sarcoma is the most frequently represented malignant tumor targeting hand soft tissues. The knowledge regarding diagnostic and therapeutic management of these tumors is often deriving from small case series, retrospective studies or even case reports. Evidences from prospective studies or controlled trials are limited and for this lack of clear and supported evidences data from the medical literature on the topic are controversial, in terms of demographics, clinical presentation, diagnosis prognosis and therapy.The correct recognition of the specific subtype and extension of the tumor through first line and second line radiology is essential for the surgeon, in order to effectively direct the therapeutic decisions.


Biosensors ◽  
2021 ◽  
Vol 11 (3) ◽  
pp. 67
Author(s):  
Song Joo Lee ◽  
Yong-Eun Cho ◽  
Kyung-Hyun Kim ◽  
Deukhee Lee

Knowing the material properties of the musculoskeletal soft tissue could be important to develop rehabilitation therapy and surgical procedures. However, there is a lack of devices and information on the viscoelastic properties of soft tissues around the lumbar spine. The goal of this study was to develop a portable quantifying device for providing strain and stress curves of muscles and ligaments around the lumbar spine at various stretching speeds. Each sample was conditioned and applied for 20 repeatable cyclic 5 mm stretch-and-relax trials in the direction and perpendicular direction of the fiber at 2, 3 and 5 mm/s. Our device successfully provided the stress and strain curve of the samples and our results showed that there were significant effects of speed on the young’s modulus of the samples (p < 0.05). Compared to the expensive commercial device, our lower-cost device provided comparable stress and strain curves of the sample. Based on our device and findings, various sizes of samples can be measured and viscoelastic properties of the soft tissues can be obtained. Our portable device and approach can help to investigate young’s modulus of musculoskeletal soft tissues conveniently, and can be a basis for developing a material testing device in a surgical room or various lab environments.


Arthroplasty ◽  
2021 ◽  
Vol 3 (1) ◽  
Author(s):  
Toni Wendler ◽  
Torsten Prietzel ◽  
Robert Möbius ◽  
Jean-Pierre Fischer ◽  
Andreas Roth ◽  
...  

Abstract Background All current total hip arthroplasty (THA) systems are modular in design. Only during the operation femoral head and stem get connected by a Morse taper junction. The junction is realized by hammer blows from the surgeon. Decisive for the junction strength is the maximum force acting once in the direction of the neck axis, which is mainly influenced by the applied impulse and surrounding soft tissues. This leads to large differences in assembly forces between the surgeries. This study aimed to quantify the assembly forces of different surgeons under influence of surrounding soft tissue. Methods First, a measuring system, consisting of a prosthesis and a hammer, was developed. Both components are equipped with a piezoelectric force sensor. Initially, in situ experiments on human cadavers were carried out using this system in order to determine the actual assembly forces and to characterize the influence of human soft tissues. Afterwards, an in vitro model in the form of an artificial femur (Sawbones Europe AB, Malmo, Sweden) with implanted measuring stem embedded in gelatine was developed. The gelatine mixture was chosen in such a way that assembly forces applied to the model corresponded to those in situ. A study involving 31 surgeons was carried out on the aforementioned in vitro model, in which the assembly forces were determined. Results A model was developed, with the influence of human soft tissues being taken into account. The assembly forces measured on the in vitro model were, on average, 2037.2 N ± 724.9 N, ranging from 822.5 N to 3835.2 N. The comparison among the surgeons showed no significant differences in sex (P = 0.09), work experience (P = 0.71) and number of THAs performed per year (P = 0.69). Conclusions All measured assembly forces were below 4 kN, which is recommended in the literature. This could lead to increased corrosion following fretting in the head-neck interface. In addition, there was a very wide range of assembly forces among the surgeons, although other influencing factors such as different implant sizes or materials were not taken into account. To ensure optimal assembly force, the impaction should be standardized, e.g., by using an appropriate surgical instrument.


2021 ◽  
Vol 23 (9) ◽  
Author(s):  
Andrea Di Matteo ◽  
Gianluca Smerilli ◽  
Edoardo Cipolletta ◽  
Fausto Salaffi ◽  
Rossella De Angelis ◽  
...  

Abstract Purpose of Review To highlight the potential uses and applications of imaging in the assessment of the most common and relevant musculoskeletal (MSK) manifestations in systemic lupus erythematosus (SLE). Recent Findings Ultrasound (US) and magnetic resonance imaging (MRI) are accurate and sensitive in the assessment of inflammation and structural damage at the joint and soft tissue structures in patients with SLE. The US is particularly helpful for the detection of joint and/or tendon inflammation in patients with arthralgia but without clinical synovitis, and for the early identification of bone erosions. MRI plays a key role in the early diagnosis of osteonecrosis and in the assessment of muscle involvement (i.e., myositis and myopathy). Conventional radiography (CR) remains the traditional gold standard for the evaluation of structural damage in patients with joint involvement, and for the study of bone pathology. The diagnostic value of CR is affected by the poor sensitivity in demonstrating early structural changes at joint and soft tissue level. Computed tomography allows a detailed evaluation of bone damage. However, the inability to distinguish different soft tissues and the need for ionizing radiation limit its use to selected clinical circumstances. Nuclear imaging techniques are valuable resources in patients with suspected bone infection (i.e., osteomyelitis), especially when MRI is contraindicated. Finally, dual energy X-ray absorptiometry represents the imaging mainstay for the assessment and monitoring of bone status in patients with or at-risk of osteoporosis. Summary Imaging provides relevant and valuable information in the assessment of MSK involvement in SLE.


2021 ◽  
Vol 40 (S1) ◽  
Author(s):  
Fatimah Othman ◽  
Rashidah Ambak ◽  
Mohd Azahadi Omar ◽  
Suzana Shahar ◽  
Noor Safiza Mohd Nor ◽  
...  

Abstract Background Monitoring sodium intake through 24-h urine collection sample is recommended, but the implementation of this method can be difficult. The objective of this study was to develop and validate an equation using spot urine concentration to predict 24-h sodium excretion in the Malaysian population. Methods This was a Malaysian Community Salt Study (MyCoSS) sub-study, which was conducted from October 2017 to March 2018. Out of 798 participants in the MyCoSS study who completed 24-h urine collection, 768 of them have collected one-time spot urine the following morning. They were randomly assigned into two groups to form separate spot urine equations. The final spot urine equation was derived from the entire data set after confirming the stability of the equation by double cross-validation in both study groups. Newly derived spot urine equation was developed using the coefficients from the multiple linear regression test. A Bland-Altman plot was used to measure the mean bias and limits of agreement between estimated and measured 24-h urine sodium. The estimation of sodium intake using the new equation was compared with other established equations, namely Tanaka and INTERSALT. Results The new equation showed the least mean bias between measured and predicted sodium, − 0.35 (− 72.26, 71.56) mg/day compared to Tanaka, 629.83 (532.19, 727.47) mg/day and INTERSALT, and 360.82 (284.34, 437.29) mg/day. Predicted sodium measured from the new equation showed greater correlation with measured sodium (r = 0.50) compared to Tanaka (r =0.24) and INTERSALT (r = 0.44), P < 0.05. Conclusion Our newly developed equation from spot urine can predict least mean bias of sodium intake among the Malaysian population when 24-h urine sodium collection is not feasible.


2021 ◽  
pp. 105566562110076
Author(s):  
Maria Costanza Meazzini ◽  
Noah Cohen ◽  
Valeria Marinella Augusta Battista ◽  
Cristina Incorvati ◽  
Federico Biglioli ◽  
...  

Background: Closure of wide alveolar clefts with large soft tissue gaps and reconstruction of the dentoalveolar defect are challenging for the surgeon. Some authors successfully used interdental segmental distraction, which requires an additional surgical procedure. Objective: This study evaluates the effectiveness of tooth borne devices utilized to orthopedically advance the lesser segments, with a complete approximation of the soft tissue of the alveolar stumps, allowing traditional simultaneous soft tissue closure and bone grafting, and avoiding the need for supplementary surgery. Methods: Eight growing patients, 2 with unilateral complete cleft lip and palate (UCLP) and 6 with bilateral complete cleft lip and palate (BCLP), with large soft tissue and bony alveolar defects prior to bone grafting were prospectively selected. A banded rapid palatal expander (RPE) in BCLP and a modified RPE in UCLP combined with protraction face mask in younger patients or a modified Alt-Ramec in patients older than 12 years were applied. Radiographic and photographic records were available at T0, at the end of protraction (T1) and at least 1 year after bone grafting (T2). Results: Patients with large gaps showed a significant reduction in the bony cleft area and approximation of the soft tissues at T1. All patients received bone grafting with good healing and ossification at T2. Conclusion: In growing patients with UCLP and BCLP with large gaps, presurgical orthodontic protraction seems to be an efficient method to reduce the cleft defect, minimizing the risk of post grafting fistulas, reducing the need for supplementary surgical procedures.


2020 ◽  
Vol 54 (4) ◽  
pp. 289-296
Author(s):  
Adeeba Ali ◽  
Anil K. Chandna ◽  
Anshul Munjal

Background: Concerns about the accuracy and reliability of soft tissue landmarks using two-dimensional (2D) and three-dimensional (3D) imaging. Objective: The aim of the systematic review is to estimate accuracy and reliability of soft tissue landmarks with 2D imaging and 3D imaging for orthodontic diagnosis planning and treatment planning purposes. Data Sources: Electronic database search was performed in MEDLINE via PubMed, Embase via embase.com, and the Cochrane library website. Selection Criteria: The data were extracted according to two protocols based on Centre for Evidence-Based Medicine (CEBM) critical appraisal tools. Next, levels of evidence were categorized into three groups: low, medium, and high. Data Synthesis: Fifty-five publications were found through database search strategies. A total of nine publications were included in this review. Conclusion According to the available literature, 3D imaging modalities were more accurate and reliable as compared to 2D modalities. Cone beam computed tomography (CBCT) was considered the most reliable imaging tool for soft tissues.


Sign in / Sign up

Export Citation Format

Share Document