scholarly journals The OMERACT MRI in Enthesitis Initiative: Definitions of Key Pathologies, Suggested MRI Sequences, and a Novel Heel Enthesitis Scoring System

2019 ◽  
Vol 46 (9) ◽  
pp. 1232-1238 ◽  
Author(s):  
Ashish J. Mathew ◽  
Simon Krabbe ◽  
Iris Eshed ◽  
Frédérique Gandjbakhch ◽  
Paul Bird ◽  
...  

Objective.To develop and validate an enthesitis magnetic resonance imaging (MRI) scoring system for spondyloarthritis/psoriatic arthritis, using the heel as model.Methods.Consensus definitions of key pathologies and 3 heel enthesitis multireader scoring exercises were done, separated by discussion, training, and calibration.Results.Definitions for bone and soft tissue pathologies were agreed. In the final exercise, median pairwise single-measures intraclass correlation coefficients (ICC; patient-level) for entheseal inflammation status/change scores were 0.83/0.82 for all readers. For radiologists and selected rheumatologists, ICC were 0.91/0.84 and quadratic-weighted κ (lesion-level) 0.57–0.91/0.45–0.81.Conclusion.The proposed definitions and Heel Enthesitis Scoring System (HEMRIS) are reliable among trained readers and promising for clinical trials.

2018 ◽  
Vol 46 (9) ◽  
pp. 1228-1231
Author(s):  
Féline P.B. Kroon ◽  
Sjoerd van Beest ◽  
Frédérique Gandjbakhch ◽  
Charles G. Peterfy ◽  
Su Chen ◽  
...  

Objective.To assess the longitudinal reliability of the Outcome Measures in Rheumatology (OMERACT) Thumb base Osteoarthritis Magnetic resonance imaging (MRI) Scoring system (TOMS).Methods.Paired MRI of patients with hand osteoarthritis were scored in 2 exercises (6-mo and 2-yr followup) for synovitis, subchondral bone defects (SBD), osteophytes, cartilage assessment, bone marrow lesions (BML), and subluxation. Interreader reliability of delta scores was assessed.Results.Little change occurred. Average-measure intraclass correlation coefficients were good-excellent (≥ 0.71), except synovitis (0.55–0.83) and carpometacarpal-1 osteophytes/cartilage assessment (0.47/0.39). Percentage exact/close agreement was 52–92%/68–100%, except BML in 2 years (28%/64–76%). Smallest detectable change was below the scoring increment, except in SBD and BML.Conclusion.TOMS longitudinal reliability was moderate-good. Limited change hampered assessment.


2017 ◽  
Vol 11 (1_suppl) ◽  
pp. 52-58 ◽  
Author(s):  
Adam C. Watson ◽  
Richard P. Jamieson ◽  
Andrew C. Mattin ◽  
Richard S. Page

Background We aimed to assess the validity of magnetic resonance imaging (MRI) in assessing the subcorocoid space and determine the validity of novel sagittal plane subcorocoid space measurements. Methods We assessed 33 arthroscopically proven subscapularis tears with MRIs compared to 33 (instability) controls with normal subscapularis tendons. Three examiners analyzed MRIs for seven static indices of corocoid morphology, in axial and sagittal planes. We explored reviewer variation using intraclass correlation coefficients (ICC) and differences between the two groups was explored using t-tests. Results Groups were similar in characteristics but different in age (cases = 53, controls = 23). ICC showed good (2/7) or excellent (5/7) reliability. Small differences(<1.6 mm) were identified between subscapularis tears and controls in coraco–humeral distance, in axial ( p = 0.092) and sagittal planes ( p = 0.045). There were statistically significant differences between groups when analyzing the angular projection of the coracoid from the glenoid, in both sagittal ( p < 0.0001) and axial planes ( p = 0.045). Conclusions Acute inferior angulation of the corocoid in the sagittal plane may be associated with subscapularis tears. Static indices are measured within the scapula and not affected by arm position. MRI reliably provided a platform to assess the coracoid. Based on this, we currently consider corocoplasty in patients with subscapularis tears and a sagittal coroco–glenoid angle <60o to reduce potential impingement.


1998 ◽  
Vol 47 (2) ◽  
pp. 89-100 ◽  
Author(s):  
I. Bonan ◽  
A.M. Argenti ◽  
M. Duyme ◽  
D. Hasboun ◽  
A. Dorion ◽  
...  

AbstractThe cerebral central sulci, seat of the sensorimotor cortex, vary anatomically in form, length and depth among individuals and present a left/right asymmetry. The purpose of this work was to measure central sulcus's lengths, at the surface and in-depth, in each hemisphere of monozygotic twins in order to evaluate the influence of environmental factors on the morphometry and asymmetry of this structure. A measurement technique on MR images of the brains using 3 D software was developed. Two operators applied this technique to measure central sulcus lengths at the surface of the brain and in-depth in each hemisphere. Besides the fact that the technique developed gave high Intraclass Correlation Coefficients (ICC) for the surface lengths (mean value 0.94), and slightly less high for the in-depth length (mean value 0.87), we found a weak (from 0.57 to 0.73 for raw data) but significant ICC between homologous sulci in pairs of twins. In addition, the ICC for asymmetry indices were not significant. Hence, if central sulcus morphometry is in part genetically influenced, these results show that nongenetic factors are nonetheless important in their development.


2020 ◽  
pp. 135245852096879
Author(s):  
KH Lam ◽  
KA Meijer ◽  
FC Loonstra ◽  
EME Coerver ◽  
J Twose ◽  
...  

Background: Clinical measures in multiple sclerosis (MS) face limitations that may be overcome by utilising smartphone keyboard interactions acquired continuously and remotely during regular typing. Objective: The aim of this study was to determine the reliability and validity of keystroke dynamics to assess clinical aspects of MS. Methods: In total, 102 MS patients and 24 controls were included in this observational study. Keyboard interactions were obtained with the Neurokeys keyboard app. Eight timing-related keystroke features were assessed for reliability with intraclass correlation coefficients (ICCs); construct validity by analysing group differences (in fatigue, gadolinium-enhancing lesions on magnetic resonance imaging (MRI), and patients vs controls); and concurrent validity by correlating with disability measures. Results: Reliability was moderate in two (ICC = 0.601 and 0.742) and good to excellent in the remaining six features (ICC = 0.760–0.965). Patients had significantly higher keystroke latencies than controls. Latency between key presses correlated the highest with Expanded Disability Status Scale ( r = 0.407) and latency between key releases with Nine-Hole Peg Test and Symbol Digit Modalities Test (ρ = 0.503 and r = −0.553, respectively), ps < 0.001. Conclusion: Keystroke dynamics were reliable, distinguished patients and controls, and were associated with clinical disability measures. Consequently, keystroke dynamics are a promising valid surrogate marker for clinical disability in MS.


2017 ◽  
Vol 44 (11) ◽  
pp. 1688-1693 ◽  
Author(s):  
Daniel Glinatsi ◽  
Paul Bird ◽  
Frédérique Gandjbakhch ◽  
Espen A. Haavardsholm ◽  
Charles G. Peterfy ◽  
...  

Objective.To develop and validate a magnetic resonance imaging (MRI) tenosynovitis (TS) score for tendons at the wrist and metacarpophalangeal (MCP) joint levels in patients with rheumatoid arthritis (RA).Methods.Axial T1-weighted precontrast and postcontrast fat-saturated MR image sets of the hands of 43 patients with RA initiating rituximab therapy were obtained at baseline and after 14, 26, 38, or 52 weeks. The MR images were scored twice by 4 readers. Nine tendon compartments of the wrist and 4 flexor tendon compartments at the MCP joints were assessed. Tenosynovitis was scored as follows: 0: No; 1: < 1.5 mm; 2: ≥ 1.5 mm but < 3 mm; 3: ≥ 3 mm peritendinous effusion and/or postcontrast enhancement. Intrareader and interreader intraclass correlation coefficients (ICC), smallest detectable change (SDC), percentage of exact and close agreement (PEA/PCA), and standardized response mean (SRM) were calculated.Results.Intrareader and interreader ICC for status and change scores were very good (≥ 0.80) for total scores for all readers. Intrareader SDC was ≤ 3.0 and interreader SDC was < 2.0. The overall PEA/PCA intrareader and interreader agreements for change scores in all tendons were 73.8%/97.6% and 47.9%/85.0%, respectively. Average SRM was moderate for total scores and 60.5% of the patients had a tenosynovitis change score ≥ SDC.Conclusion.The TS score showed high intrareader and interreader agreement for wrist and finger tendons, with moderate responsiveness, and the majority of the patients showed a change above the SDC. This scoring system may be included as a component of the RAMRIS.


2013 ◽  
Vol 41 (2) ◽  
pp. 386-391 ◽  
Author(s):  
Ida K. Haugen ◽  
Mikkel Østergaard ◽  
Iris Eshed ◽  
Fiona M. McQueen ◽  
Paul Bird ◽  
...  

Objective.To develop and test the interreader reliability of the OMERACT Hand Osteoarthritis Magnetic Resonance Scoring System (HOAMRIS) for assessment of structural and inflammatory hand OA features in the interphalangeal joints.Methods.The HOAMRIS was developed through an iterative process. Selection of features and their scaling was agreed upon through consensus by members of the OMERACT Magnetic Resonance Imaging (MRI) Task Force, using the Oslo Hand Osteoarthritis (OA) MRI Score system as a template. Two reliability exercises were performed, in which 6 and 4 readers participated, respectively. After the first exercise, an atlas was developed and used in the second exercise to facilitate reading. In each exercise, readers independently scored 8 MRI scans from the Oslo Hand OA cohort (coronal/axial short-tau inversion recovery and coronal/axial/sagittal T1-weighted fat-suppressed pre-/post-Gadolinium images). Interreader reliability was assessed by intraclass correlation coefficients (ICC), percentage exact and close agreement (PEA/PCA).Results.The preliminary OMERACT HOAMRIS included assessment of synovitis, erosive damage, cysts, osteophytes, cartilage space loss, malalignment, and bone marrow lesions (BML), of which all were scored on a 0–3 scale for normal, mild, moderate, and severe (increments of 0.5 for synovitis, erosive damage, and BML). In the first exercise, most features showed good to very good ICC values (0.64–0.94), except synovitis (0.34). In the second exercise using the atlas, the ICC values were > 0.74 for all MRI features, and the PEA/PCA values were higher than in the first exercise.Conclusion.A preliminary HOAMRIS with good to very good interreader reliability was developed. Longitudinal studies are needed to assess its sensitivity to change.


2015 ◽  
Vol 42 (12) ◽  
pp. 2486-2491 ◽  
Author(s):  
Ida K. Haugen ◽  
Iris Eshed ◽  
Frederique Gandjbakhch ◽  
Violaine Foltz ◽  
Mikkel Østergaard ◽  
...  

Objective.To evaluate the interreader reliability of change scores and the responsiveness of the OMERACT Hand Osteoarthritis (OA) Magnetic Resonance Image (MRI) Scoring System (HOAMRIS).Methods.Paired MRI (baseline and 5-yr followup) from 20 patients with hand OA were scored with known time sequence by 3 readers according to the HOAMRIS: Synovitis, erosive damage, cysts, osteophytes, cartilage space loss, malalignment, and bone marrow lesions (BML; 0–3 scales with 0.5 increments for synovitis, erosive damage, and BML). Interreader reliability for status and change scores were assessed by intraclass correlation coefficients (ICC), percentage exact agreement and percentage close agreement (PEA/PCA), and smallest detectable change (SDC). Responsiveness was assessed by standardized response means (SRM).Results.Cross-sectional interreader ICC were good to very good (≥ 0.74) for all features except synovitis, cysts, and malalignment (ICC 0.50–0.58). The range of change values was small, leading to low ICC for change scores. The SDC values for sum scores (total range 0–24) varied between 1.97–3.05 (except 1.08 for malalignment). For status scores, PEA/PCA on scores in individual joints across the readers were 8.1–50.0 and 43.8–78.1, respectively. Similarly, PEA/PCA for change scores were 20.6–63.8 and 66.3–93.1, respectively. All features except cysts and BML demonstrated good responsiveness with higher SRM for sum scores (range 0.46–1.62) than for scores in individual joints (range 0.24–0.73).Conclusion.Good to very good interreader ICC values were found for cross-sectional readings, whereas the longitudinal reliability was lower because of a smaller range of change scores. All features, except cysts and BML, showed good responsiveness.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Ji Hyun Lee ◽  
Gyu Sang Yoo ◽  
Young Cheol Yoon ◽  
Hee Chul Park ◽  
Hyun Su Kim

AbstractThe objectives of this study were to assess changes in apparent diffusion coefficient (ADC) and dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) parameters after radiation therapy (RT) for bone metastases from hepatocellular carcinoma (HCC) and to evaluate their prognostic value. This prospective study was approved by the Institutional Review Board. Fourteen patients with HCC underwent RT (30 Gy in 10 fractions once daily) for bone metastases. The ADC and DCE-MRI parameters and the volume of the target lesions were measured before (baseline) and one month after RT (post-RT). The Wilcoxon signed-rank test was used to compare the parameters between the baseline and post-RT MRI. The parameters were compared between patients with or without disease progression in RT fields using the Mann–Whitney test. Intraclass correlation coefficients were used to evaluate the interobserver agreement. The medians of the ADC, rate constant [kep], and volume fraction of the extravascular extracellular matrix [ve] in the baseline and post-RT MRI were 0.67 (range 0.61–0.72) and 0.75 (range 0.63–1.43) (× 10–3 mm2/s) (P = 0.027), 836.33 (range 301.41–1082.32) and 335.80 (range 21.86–741.87) (× 10–3/min) (P = 0.002), and 161.54 (range 128.38–410.13) and 273.99 (range 181.39–1216.95) (× 10–3) (P = 0.027), respectively. The medians of the percent change in the ADC of post-RT MRI in patients with progressive disease and patients without progressive disease were − 1.35 (range − 6.16 to 6.79) and + 46.71 (range 7.71–112.81) (%) (P = 0.011), respectively. The interobserver agreements for all MRI parameters were excellent (intraclass correlation coefficients > 0.8). In conclusion, the ADC, kep, and ve of bone metastases changed significantly after RT. The percentage change in the ADC was closely related to local tumor progression.


1991 ◽  
Vol 34 (5) ◽  
pp. 989-999 ◽  
Author(s):  
Stephanie Shaw ◽  
Truman E. Coggins

This study examines whether observers reliably categorize selected speech production behaviors in hearing-impaired children. A group of experienced speech-language pathologists was trained to score the elicited imitations of 5 profoundly and 5 severely hearing-impaired subjects using the Phonetic Level Evaluation (Ling, 1976). Interrater reliability was calculated using intraclass correlation coefficients. Overall, the magnitude of the coefficients was found to be considerably below what would be accepted in published behavioral research. Failure to obtain acceptably high levels of reliability suggests that the Phonetic Level Evaluation may not yet be an accurate and objective speech assessment measure for hearing-impaired children.


Author(s):  
Marcos A Soriano ◽  
G Gregory Haff ◽  
Paul Comfort ◽  
Francisco J Amaro-Gahete ◽  
Antonio Torres-González ◽  
...  

The aims of this study were to (I) determine the differences and relationship between the overhead press and split jerk performance in athletes involved in weightlifting training, and (II) explore the magnitude of these differences in one-repetition maximum (1RM) performances between sexes. Sixty-one men (age: 30.4 ± 6.7 years; height: 1.8 ± 0.5 m; body mass 82.5 ± 8.5 kg; weightlifting training experience: 3.7 ± 3.5 yrs) and 21 women (age: 29.5 ± 5.2 yrs; height: 1.7 ± 0.5 m; body mass: 62.6 ± 5.7 kg; weightlifting training experience: 3.0 ± 1.5 yrs) participated. The 1RM performance of the overhead press and split jerk were assessed for all participants, with the overhead press assessed on two occasions to determine between-session reliability. The intraclass correlation coefficients (ICC) and 95% confidence intervals showed a high reliability for the overhead press ICC = 0.98 (0.97 – 0.99). A very strong correlation and significant differences were found between the overhead press and split jerk 1RM performances for all participants (r = 0.90 [0.93 – 0.85], 60.2 ± 18.3 kg, 95.7 ± 29.3 kg, p ≤ 0.001). Men demonstrated stronger correlations between the overhead press and split jerk 1RM performances (r = 0.83 [0.73-0.90], p ≤ 0.001) compared with women (r = 0.56 [0.17-0.80], p = 0.008). These results provide evidence that 1RM performance of the overhead press and split jerk performance are highly related, highlighting the importance of upper-limb strength in the split jerk maximum performance.


Sign in / Sign up

Export Citation Format

Share Document