scholarly journals Helical computed tomography application in rabbit liver anatomy: comparison with frozen cross-sectional cuts

2013 ◽  
Vol 37 ◽  
pp. 553-558 ◽  
Author(s):  
Kamelia STAMATOVA YOVCHEVA ◽  
Rosen DIMITROV ◽  
Yuliana TONEVA ◽  
Penka YONKOVA ◽  
Dimitar KOSTOV ◽  
...  
2009 ◽  
Vol 36 (9) ◽  
pp. 1958-1962 ◽  
Author(s):  
TORU SHIMIZU ◽  
HIROSHI HORI

Objective.To investigate the prevalence of nephrolithiasis in gouty patients by computed tomography (CT) imaging and to compare it with the “prevalence” of urolithiasis calculated from histories of urinary tract calculus.Methods.The kidneys of 383 male patients with primary gout were examined using an unenhanced 2-row helical CT detector, imaging at 2 mm collimation and a helical pitch of 3. The urolithiasis history of the 383 patients was investigated by inquiry. Patients’ ages, body mass index, and laboratory data from a 1-hour clearance test were determined.Results.CT scans confirmed nephrolithiasis in 103 (26.9%, 95% confidence interval 22.5%–31.6%) of the 383 gouty patients, and history of urinary calculus was positive in 65 (17.0%, 95% confidence interval 13.4%–21.1%) of the 383. However, 64 (62%) of the 103 stone-formers identified by CT had no history of urolithiasis. There was a significant difference between the ages of the 103 stone-formers identified by CT and the 65 stone-formers identified from the history.Conclusion.The prevalence of nephrolithiasis obtained using CT was 26.9% in the 383 patients with primary gout. Our results imply that we cannot determine an accurate prevalence of urolithiasis from a patient’s history. Most of the “prevalence” reported in the past may not correspond to a statistically justifiable one, but instead to the “cumulative incidence” during the contraction period of gout. Thus, the prevalence of nephrolithiasis confirmed by a cross-sectional method and the “prevalence” of urolithiasis calculated from patients’ calculus histories should be clearly distinguished.


2020 ◽  
Vol 6 (2) ◽  
pp. 78-81
Author(s):  
Md Tauhidul Islam Chowdhury ◽  
Mohammad Shah Jahirul Hoque Chowdhury ◽  
Mohammad Sadekur Rahman Sarkar ◽  
KM Ahasan Ahmed ◽  
Md Nazmul Kabir ◽  
...  

Background: In evaluation of non-traumatic subarachnoid hemorrhage CT angiography (CTA) has 97-98% sensitivity and near 100% specificity. Objective: This study was conducted to evaluate the CTA findings of CT positive non traumatic subarachnoid hemorrhage. Methodology: This is an observational cross sectional study performed in Neurology department of National Institute of Neurosciences and Hospital, Dhaka over one year period (January 2019 to December 2019). Total 87 CT positive subarachnoid hemorrhage cases were purposively included in this study. All CT positive patients underwent CTA of Cerebral vessels for further evaluation. The angiography were evaluated by competent neuro-radiologists blinded about the study. Result: Among 87 patients, 40.2% were male and 59.8% were female. The average age was 53.33±11.1 years. Among the studied patient the source of bleeding was found 78.16% aneurysmal and 21.84% non-aneurysmal. 85.30% patients had single aneurysm and 14.70% had multiple aneurysm. The highest number of patient had Acom aneurysm (41.17%) followed by MCA (22.05%), ICA (13.23%), ACA (7.35%) and vertebral artery (1.14%) in order of frequency. Among the multiple aneurysm group most of the patients had combination of Acom, MCA and ICA aneurysm. Conclusion: From this study, we can conclude that CTA can be used as the primary diagnostic tool in evaluation of spontaneous SAH. Journal of National Institute of Neurosciences Bangladesh, 2020;6(2): 78-81


Circulation ◽  
2002 ◽  
Vol 106 (5) ◽  
pp. 637-638 ◽  
Author(s):  
Zhao Shaohong ◽  
Nie Yongkang ◽  
Cai Zulong ◽  
Zhao Hong ◽  
Yang Li

Diagnostics ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 757
Author(s):  
Maged Sultan Alhammadi ◽  
Abeer Abdulkareem Al-mashraqi ◽  
Rayid Hussain Alnami ◽  
Nawaf Mohammad Ashqar ◽  
Omar Hassan Alamir ◽  
...  

The study sought to assess whether the soft tissue facial profile measurements of direct Cone Beam Computed Tomography (CBCT) and wrapped CBCT images of non-standardized facial photographs are accurate compared to the standardized digital photographs. In this cross-sectional study, 60 patients with an age range of 18–30 years, who were indicated for CBCT, were enrolled. Two facial photographs were taken per patient: standardized and random (non-standardized). The non-standardized ones were wrapped with the CBCT images. The most used soft tissue facial profile landmarks/parameters (linear and angular) were measured on direct soft tissue three-dimensional (3D) images and on the photographs wrapped over the 3D-CBCT images, and then compared to the standardized photographs. The reliability analysis was performed using concordance correlation coefficients (CCC) and depicted graphically using Bland–Altman plots. Most of the linear and angular measurements showed high reliability (0.91 to 0.998). Nevertheless, four soft tissue measurements were unreliable; namely, posterior gonial angle (0.085 and 0.11 for wrapped and direct CBCT soft tissue, respectively), mandibular plane angle (0.006 and 0.0016 for wrapped and direct CBCT soft tissue, respectively), posterior facial height (0.63 and 0.62 for wrapped and direct CBCT soft tissue, respectively) and total soft tissue facial convexity (0.52 for both wrapped and direct CBCT soft tissue, respectively). The soft tissue facial profile measurements from either the direct 3D-CBCT images or the wrapped CBCT images of non-standardized frontal photographs were accurate, and can be used to analyze most of the soft tissue facial profile measurements.


Sign in / Sign up

Export Citation Format

Share Document