Simultaneous determination of aflatoxin B1, aflatoxin B2, mycophenolic acid and sterigmatocystin in grape pomace by UHPLC-MS/MS

2014 ◽  
Vol 7 (2) ◽  
pp. 121-129 ◽  
Author(s):  
L. Luan ◽  
N. Chen ◽  
Z. Han ◽  
X. Liu ◽  
Y. Zheng ◽  
...  

A reliable ultrahigh performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed for the simultaneous determination of aflatoxin B1, aflatoxin B2, mycophenolic acid and sterigmatocystin in grape pomace. The samples were extracted by acetonitrile aqueous solution and further purified using a solid-phase extraction-based homemade clean-up cartridge. Next, the analytes were separated on a reversed-phase C18 column with a mobile phase consisting of water and acetonitrile. The separated compounds were detected with a tandem quadrupole mass spectrometer operating in positive electro-spray ionisation mode using multiple reaction monitoring. The established method was extensively validated by determining linearity (R2≯0.999), recovery (97.5-102.8%) and precision (relative standard deviation ≤7.0%). This method was then used for the simultaneous determination of the four mycotoxins in grape pomace samples.

Molecules ◽  
2018 ◽  
Vol 23 (12) ◽  
pp. 3215 ◽  
Author(s):  
Yingyu Wang ◽  
Xiaowei Li ◽  
Yuebin Ke ◽  
Chengfei Wang ◽  
Yuan Zhang ◽  
...  

A rapid, reliable, and sensitive method was developed for the determination of ten tranquilizers in swine urine. Sample preparation was based on solid-phase extraction, which combined isolation of the compounds and sample cleanup in a single step. Separation was performed on a reversed phase C18 column by gradient elution with a chromatographic run time of seven minutes, consisting of 0.1% formic acid in water and acetonitrile as the mobile phase. Multiple reaction monitoring in positive mode was applied for data acquisition. Matrix-matched calibration was used for quantification and good linearity was obtained with coefficients of determination higher than 0.99. The average recoveries of fortified samples at concentrations between 0.05 and 10 µg/L ranged from 85% to 106% with interday relative standard deviations of less than 13% in all cases. The limits of detection and limits of quantification obtained for tranquilizers in the urine were in the ranges of 0.03–0.1 µg/L and 0.05–0.25 µg/L, respectively. The applicability of the proposed method was demonstrated by analyzing real samples; diazepam was detected at concentrations between 0.3 and 0.6 μg/L.


2013 ◽  
Vol 634-638 ◽  
pp. 1586-1590
Author(s):  
Su Fang Wang ◽  
Shou Jie Zhang ◽  
Chun Hong Dong ◽  
Guo Qing Wang ◽  
Jun Feng Guo ◽  
...  

A method for simultaneous determination of residuals of four herbicides and pesticides, simazine, carboxin, diflubenzuron and rotenone, in Chinese green tea was developed. In the proposed method, the tea powder was placed in a centrifuge tube with a plug, extracted in saturated aqueous sodium chloride solution and acetonitrile, agitated using vortex oscillator, and then centrifuged 5 min at 4000 rpm. The supernatant solution was purified by primary secondary amine (PSA) sorbent, C18 power, and graphitized carbon black powder, respectively. Then the purified extracts were dissolved with acetonitrile:0.1% formic acid aqueous solution (40:60, V/V) and agitated, filtered using a syringe with 0.22 μm nylon filter prior to UPLC-MS/MS analysis. The UPLC analysis was performed on an ACQUITY UPLC® HSS T3 column (2.1 mm×100 mm, 1.8 µm), using acetonitrile-0.1% formic acid as mobile phase with the flow rate as 0.3 mL•min-1. Injection volume was 10 µL. Positive ionization mode was applied, and the ions were monitored in the multiple reaction monitoring (MRM) mode with curtain gas 0.069 MPa, collision gas 0.052 MPa, ESI ion spray voltage 5000 V, temperature 550 °C, nebulizer gas 0.24 MPa, and turbo gas 0.28 MPa. The limit of detection (LOD) and limit of quantitation (LOQ) of the proposed method are 1 μg•kg-1and 5 μg•kg-1, respectively. The average recoveries of the four pesticides at 10, 20, and 50 µg•kg-1spiking levels range from 77.4% to 95.3%. TheSupersSuperscript textcript textrelative standard deviation (RSD) (n=6) range form 11.83% to 4.52%.


2012 ◽  
Vol 48 (2) ◽  
pp. 315-323 ◽  
Author(s):  
Paulo Cesar Pires Rosa ◽  
Isabel Cristina Sales Fontes Jardim

A new, simple, fast, reproducible and sensitive reversed phase HPLC method, using a new stationary phase containing embedded urea polar groups, has been developed and validated for the simultaneous determination of clobutinol hydrochloride (CLO) and doxylamine succinate (DOX) in syrups. The determination was carried out on a C8 urea column (125 mm x 3.9 mm i.d., 5 µm particle size) synthetized at the Liquid Chomatography Laboratory (LabCrom) of the Chemistry Institute of Unicamp. The mobile phase consisted of a mixture of acetonitrile:methanol:phosphate buffer (pH 2.5) in the gradient mode. The diode array detector (DAD) was operated at 230 nm for CLO and 262 nm for DOX. The method showed adequate precision, with relative standard deviations (RSD) less than 1%. The presence of the excipients did not interfere in the results of the analysis. Accuracy was determined by adding standards of the drugs to a placebo and good recovery values were obtained. The analytical curves were linear (r² 0.9999 for CLO and 0.9998 for DOX) over a wide concentration range (2.4-336 µg mL-1 for CLO and 2.3-63 µg mL-1 for DOX). The solutions were stable for at least 72 hours at room temperature. The criteria for validation using the ICH guidelines were fulfilled.


2001 ◽  
Vol 84 (3) ◽  
pp. 676-683 ◽  
Author(s):  
Natividad Ramos-Martos ◽  
Francisco Aguirre-Gómez ◽  
Antonio Molina-Díaz ◽  
Luis F Capitán-Vallvey

Abstract This paper describes a rapid reversed-phase liquid chromatographic method, with UV detection, for the simultaneous determination of acetylsalicylic acid, caffeine, codeine, paracetamol, pyridoxine, and thiamine in pharmaceutical preparations. A reversed-phase C18 Nucleosil column is used. The mobile phase consists of 2 successive eluants: water (5 min) and acetonitrile–water (75 + 25, v/v; 9 min), both adjusted to pH 2.1 with phosphoric acid. Before determination acetylsalicylic acid is completely converted to salicylic acid by alkaline hydrolysis. Salicylic acid, caffeine, paracetamol, pyridoxine, and thiamine are all detected at 285 nm, whereas codeine is detected at 240 nm. Calibration curves were linear for salicylic acid, caffeine, paracetamol, and pyridoxine in the range of 50–500 mg/L, and for codeine and thiamine in the range of 50–1000 mg/L. The method was applied to the analysis of 13 fortified commercial pharmaceutical preparations. Recoveries ranged from 92.6 to 105.5%, with relative standard deviations of 1.1–5.8%.


2003 ◽  
Vol 86 (4) ◽  
pp. 685-693 ◽  
Author(s):  
Guo-Fang Pang ◽  
Yan-Zhong Cao ◽  
Chun-Lin Fan ◽  
Jin-Jie Zhang ◽  
Xue-Min Li ◽  
...  

Abstract Eighteen laboratories participated in a collaborative study on the determination of clopidol residues in chicken muscle tissues by liquid chromatography. Of these, results from 16 laboratories which rigorously followed the method were subjected to statistical analysis. The method performance was assessed by all participants using 14 samples of chicken muscle fortified at concentrations ranging from 0.1 to 5.0 mg/kg. In addition, 9 participants each reported results for 6 clopidol-incurred samples in chicken muscle. Test portions were extracted with acetonitrile, and the extracts were purified with alumina and anion exchange resin solid-phase extraction cartridges in sequence. Clopidol was separated by reversed-phase liquid chromatography and quantified at 270 nm. Average recoveries ranged from 81.8 to 85.4%, reproducibility relative standard deviation (RSDR) ranged from 11.9 to 22.6%, and repeatability relative standard deviation (RSDr) ranged from 9.9 to 15.1%. For clopidol-incurred samples at concentrations of 0.100–0.687 mg/kg, the mean determination value range was 0.099–0.659 mg/kg; RSDR was 12.6–19.8%, RSDr was 3.1–8.5%; and HORRAT values were 0.7–1.1. The accuracy and precision of the method are in conformity with the requirements specified by AOAC INTERNATIONAL. The method was adopted Official First Action in April 2003.


2020 ◽  
Vol 2020 ◽  
pp. 1-16 ◽  
Author(s):  
Shilan A. Omer ◽  
Nabil A. Fakhre

Three simple precise and accurate spectrophotometric methods are developed for simultaneous determination of ternary mixtures of carboxin, chlorpyrifos, and tebuconazole residues in cabbage grown in the experimental field. The first method is a double divisor-ratio spectra derivative that relies on the derivative of ratio spectra and attained through dividing the absorption spectra of the ternary mixture by the sum of standard spectrum of a mixture of two from three components, using methanol as a solvent and measuring CAR at 242 nm, CHL at 236 nm, 276 nm, and 300 nm, and TEB at 226 nm. The second method is a successive derivative of ratio spectra which determined CAR at 256 nm and 258 nm, CHL at 290 nm and 292 nm, and TEB at 226 nm and 228 nm. The third method is a mean centering of ratio spectra where CAR, CHL, and TEB were measured at 306 nm, 280 nm, and 240 nm, respectively. These procedures do not involve any previous separation. The extraction of analytes was carried out by using acetonitrile, and the procedure of purification was fulfilled by dispersive solid-phase extraction with a primary-secondary amine (PSA). The proposed methods showed excellent linearity range for three spectrophotometric methods over the concentration ranges of 1–30 μg/mL, 1–50 μg/mL, and 1–45 μg/mL for carboxin, chlorpyrifos, and tebuconazole, respectively. The analytical characteristics such as detection limit, determination limit, relative standard deviation, and accuracy of the three methods were performed. The limits of detection were in the range of 0.153–0.260 μg/mL for carboxin, 0.137–0.272 μg/mL for chlorpyrifos, and 0.109–0.205 μg/mL for tebuconazole with limits of quantification lower than 0.790, 0.824, and 0.621 μg/mL for CAR, CHL, and TEB, respectively. The recoveries ranged from 87.02% to 94.53% for carboxin, 92.32% to 108.53% for chlorpyrifos, and 87.19% to 98.00% for tebuconazole with relative standard deviations less than 5.91%, 5.99%, and 5.53% in all instances for carboxin, chlorpyrifos, and tebuconazole, respectively. The results obtained from the proposed methods were compared statistically by using one-way ANOVA, and the results revealed that there were no significant differences between three different spectrophotometric methods. The suggested methods can be applied with great success to the simultaneous estimation of carboxin, chlorpyrifos, and tebuconazole residues in cabbage samples.


2020 ◽  
Vol 32 (2) ◽  
pp. 145-148 ◽  
Author(s):  
Siyuan Chen ◽  
Jianshe Ma ◽  
Xianqin Wang ◽  
Peiwu Geng

Hair is a stable specimen and has a longer detection window (from weeks to months) than blood and urine. Through the analysis of hair, the long-term information of the drug use of the identified person could be explored. Our work is to establish an ultra-performance liquid chromatography–tandem mass spectroscopy (UPLC–MS/MS) method for simultaneous determination of methamphetamine, amphetamine, morphine, monoacetylmorphine, ketamine, norketamine, 3,4-methylenedioxymethamphetamine (MDMA), and 3,4-methylenedioxyamphetamine (MDA) in hair. Methoxyphenamine was used as an internal standard. The chromatographic separation was performed on a UPLC ethylene bridged hybrid (BEH) C18 (2.1 mm × 50 mm, 1.7 μm) column using a mobile phase of acetonitrile–water with 10 mmol/L ammonium acetate solution which containing 0.05% ammonium hydroxide. The multiple reaction monitoring in positive electrospray ionization was used for quantitative determination. The intra-day and inter-day precisions (relative standard deviation [RSD]) were below 15%. The accuracy ranged between 85.5% and 110.4%, the average recovery rate was above 72.9%, and the matrix effect ranged between 92.7% and 109.2%. Standard curves were in the range of 0.05–5.0 ng/mg, and the correlation coefficients were greater than 0.995. The established UPLC–MS/MS method was applied to analyze the hair samples successfully.


2003 ◽  
Vol 86 (3) ◽  
pp. 612-622 ◽  
Author(s):  
Jitka Zrostlíková ◽  
Jana Hajšlová ◽  
Tomáš Kovalczuk ◽  
Radim Štěpán ◽  
Jan Poustka

Abstract A simple liquid chromatography/mass spectrome-try (LC/MS) approach for the determination of widely used representatives of polar/thermolabile pesticides in fruits was developed and validated. The group of pesticides comprised benzimidazoles and azoles (carbendazim, thiabendazole, imazalil, propiconazole, prochloraz, epoxiconazole, flusilazole, tebuconazole, bitertanol); N-methylcarbamates (carbaryl, carbofuran, methiocarb); and phenylureas and benzoylphenylureas (linuron, diflubenzuron, triflumuron, teflubenzuron, flufenoxuron). Matrixes (apple, apricot) were extracted with acetonitrile and crude extracts were cleaned up by solid-phase ex-traction (SPE) using either mixed cation exchange or hydrophilic lipophilic balance cartridges. LC separation of pesticides was performed on a reversed-phase column, Discovery C18. Electrospray ionization and ion trap MS/MS detection were applied. For most pesticides, overall recoveries ranged from 75 to 122%, and repeatability (as relative standard deviation) from 5 repetitive determinations of recovery ranged from 3 to 21%. Carbofuran was the only compound for which recovery was not satisfactory due to its loss in the SPE cleanup step. Limits of detection were 0.1–3 μg/kg for benzimidazole and azole fungicides and carbamate insecticides. For urea insecticides, detection limits were slightly higher (3–10 μg/kg).


Sign in / Sign up

Export Citation Format

Share Document