Gamma Spectroscopic Analysis and Associated Radiation Hazards Parameters of Cement Used in Saudi Arabia

2016 ◽  
Vol 9 (2) ◽  
pp. 238-245 ◽  
Author(s):  
S. Alashrah ◽  
A. El- Taher
2021 ◽  
Vol 14 (23) ◽  
Author(s):  
Helmy S. O. Abuelnaga ◽  
Essam Aboud ◽  
Faisal A. Alqahtani ◽  
Murad Abdulfarraj ◽  
Sultan Almalki ◽  
...  

2019 ◽  
Vol 44 (10) ◽  
pp. 8799-8804
Author(s):  
El-Said Ibrahim Shabana ◽  
Essam Mohammed Banoqitah ◽  
Maher Mohammad Taher Qutub ◽  
Mohammad Sami Tayeb ◽  
Abdulraheem Abdulrahman Kinsara

Author(s):  
B. J. Grenon ◽  
A. J. Tousimis

Ever since the introduction of glutaraldehyde as a fixative in electron microscopy of biological specimens, the identification of impurities and consequently their effects on biologic ultrastructure have been under investigation. Several reports postulate that the impurities of glutaraldehyde, used as a fixative, are glutaric acid, glutaraldehyde polymer, acrolein and glutaraldoxime.Analysis of commercially available biological or technical grade glutaraldehyde revealed two major impurity components, none of which has been reported. The first compound is a colorless, water-soluble liquid with a boiling point of 42°C at 16 mm. Utilizing Nuclear Magnetic Resonance (NMR) spectroscopic analysis, this compound has been identified to be — dihydro-2-ethoxy 2H-pyran. This impurity component of the glutaraldehyde biological or technical grades has an UV absorption peak at 235nm. The second compound is a white amorphous solid which is insoluble in water and has a melting point of 80-82°C. Initial chemical analysis indicates that this compound is an aldol condensation product(s) of glutaraldehyde.


Author(s):  
S. A. Livesey ◽  
A. A. del Campo ◽  
E. S. Griffey ◽  
D. Ohlmer ◽  
T. Schifani ◽  
...  

The aim of this study is to compare methods of sample preparation for elemental analysis. The model system which is used is the human erythrocyte. Energy dispersive spectroscopic analysis has been previously reported for cryofixed and cryosectioned erythrocytes. Such work represents the reference point for this study. The use of plastic embedded samples for elemental analysis has also been documented. The work which is presented here is based on human erythrocytes which have been either chemically fixed and embedded or cryofixed and subsequently processed by a variety of techniques which culminated in plastic embedded samples.Heparinized and washed erythrocytes were prepared by the following methods for this study :(1). Chemical fixation in 4% paraformaldehyde/0.25% glutaraldehyde/0.2 M sucrose in 0.1 M Na cacodylate, pH 7.3 for 30 min, followed by ethanol dehydration, infiltration and embedding in Lowicryl K4M at -20° C.


Vacunas ◽  
2020 ◽  
Vol 21 (2) ◽  
pp. 95-104 ◽  
Author(s):  
Y.M. AlGoraini ◽  
N.N. AlDujayn ◽  
M.A. AlRasheed ◽  
Y.E. Bashawri ◽  
S.S. Alsubaie ◽  
...  

2016 ◽  
Vol 22 ◽  
pp. 224
Author(s):  
Subodh Banzal ◽  
Sonal Banzal ◽  
Sadhana Banzal ◽  
Ayobenji Ayoola

Sign in / Sign up

Export Citation Format

Share Document