Rehabilitation of Strength of Steel Plate with a Corroding Hole Bonded by Composite Patches

2012 ◽  
Vol 226-228 ◽  
pp. 883-888
Author(s):  
Xiang Ming Zhang ◽  
Li Wei Chen ◽  
Ze Long You ◽  
Ming Yong Hu ◽  
Shao Hong Yang

The failure mode of steel plate with a center elliptic corroding hole double-sided adhesively bonded by carbon fiber composite patch is identified and studied, and analytical solution to load-carrying capacity of damaged steel plate bonded by composite patch is presented in this paper. Ultimate load of patched steel plate corresponding to each failure mode is derived and calculated respectively, the load carrying capacity of the patched plate is equal to the minimum value of these calculations. Yielding load when yielding occurs near the hole-edge of repaired structure from present method was compared to the results of ANSYS FEA, and the ultimate load of repaired plate from present method was compared to the test results. Results indicate: Repaired by bonded composite patch, static strength and loading carrying capacity of damaged steel plate or structures can be effectively restored. Yielding load and ultimate load of patched steel plate is visibly increased. The present analytical results have a good agreement with FEA and experimental results.

2018 ◽  
Vol 206 ◽  
pp. 02011 ◽  
Author(s):  
Hue Thi Nguyen ◽  
Hiroshi Masuya ◽  
Tuan Minh Ha ◽  
Saiji Fukada ◽  
Daishin Hanaoka ◽  
...  

Carbon fiber reinforced plastic (Carbon Fiber Composite Cable, CFCC) has the outstanding features in comparison with regular steel. In October 1988, CFCC was applied as the tensioning material in main girders of new Shinmiya Bridge in Ishikawa, Japan. This was the first bridge in Japan and in the world, which CFCC tendons were used in the prestressed concrete bridge to counter salt damage. To investigate the serviceability and durability of the main girders and CFCC, three full-scale test girders were fabricated in 1988. At the same time, a bending experiment was conducted on one girder to investigate the ultimate behavior, load carrying capacity of the PC girder, as well the strain behavior of the CFCC. Besides, two PC girders were placed next to the main girders of the bridge in the same conditions. One of them was used for a destructive test after six years of the construction time (1994). In this study, another test specimen that was exposed to the actual corrosive environment after nearly 30 years was subjected to a destructive test by bending load. The load carrying capacity of the girder was clarified, and the durability of the PC girders using CFCC tendon was confirmed.


Author(s):  
Masoud Mohammadi ◽  
Ali Sadeghi

In this paper, a new manufacturing method of pyramidal lattice cells has been suggested to produce lattice composite cylinders. Moreover, the effect of fiber volume fraction, vacuum molding, and fiber pre-tension has been investigated on the load-carrying capacity of the cylindrical pyramidal lattice structure of a carbon fiber composite. The carbon fiber composite cylindrical pyramidal lattice structure has been manufactured with laying fibers along the grooves of a silicone mold. Then, it has been subjected to the axial compressive test. Furthermore, to make pre-tension in fibers, a metal mold has been designed. Fiber pre-tension ensures the alignment of the fibers is straight between two nodal points. Additionally, the structure has been analyzed by the finite element buckling procedure. Experimental tests on the structures show that using a metal mold compare to the silicone molding method increases load-carrying capacity up to 48% without significantly varying the weight. Therefore, this method can be used for manufacturing pyramidal lattice structures in the hand layup process.


2018 ◽  
Vol 2018 ◽  
pp. 1-16 ◽  
Author(s):  
Rajinder Ghai ◽  
Prem Pal Bansal ◽  
Maneek Kumar

There is a common phenomenon of shear failure in RCC beams, especially in old buildings and bridges. Any possible strengthening of such beams is needed to be explored that could strengthen and make them fit for serviceable conditions. The present research has been made to determine the performance of predamaged beams strengthened with three-layered wire mesh polymer-modified ferrocement (PMF) with 15% styrene-butadiene-rubber latex (SBR) polymer. Forty-eight shear-designed and shear-deficient real-size beams were used in this experimental work. Ultimate shear load-carrying capacity of control beams was found at two different shear-span (a/d) ratios 1 and 3. The sets of remaining beams were loaded with different predetermined damage levels of 45%, 75%, and 95% of the ultimate load values and then strengthened with 20 mm thick PMF. The strengthened beams were then again tested for ultimate load-carrying capacity by conducting the shear load test at a/d = 1 and 3. As a result, the PMF-strengthened beams showed restoration and enhancement of ultimate shear load-carrying capacity by 5.90% to 12.03%. The ductility of strengthened beams was improved, and hence, the corresponding deflections were prolonged. On the other hand, the cracking pattern of PMF-strengthened beams was also improved remarkably.


Materials ◽  
2021 ◽  
Vol 14 (13) ◽  
pp. 3468
Author(s):  
Zbigniew Kolakowski ◽  
Andrzej Teter

The phenomena that occur during compression of hybrid thin-walled columns with open cross-sections in the elastic range are discussed. Nonlinear buckling problems were solved within Koiter’s approximation theory. A multimodal approach was assumed to investigate an effect of symmetrical and anti-symmetrical buckling modes on the ultimate load-carrying capacity. Detailed simulations were carried out for freely supported columns with a C-section and a top-hat type section of medium lengths. The columns under analysis were made of two layers of isotropic materials characterized by various mechanical properties. The results attained were verified with the finite element method (FEM). The boundary conditions applied in the FEM allowed us to confirm the eigensolutions obtained within Koiter’s theory with very high accuracy. Nonlinear solutions comply within these two approaches for low and medium overloads. To trace the correctness of the solutions, the Riks algorithm, which allows for investigating unsteady paths, was used in the FEM. The results for the ultimate load-carrying capacity obtained within the FEM are higher than those attained with Koiter’s approximation method, but the leap takes place on the identical equilibrium path as the one determined from Koiter’s theory.


2018 ◽  
Vol 22 (7) ◽  
pp. 1554-1565 ◽  
Author(s):  
Jianwei Tu ◽  
Kui Gao ◽  
Lang He ◽  
Xinping Li

At present, extensive studies have been conducted relative to the topic of fiber-reinforced polymer(FRP)- reinforced concrete (RC) flexural members, and many design methods have also been introduced. There have, however, been few studies conducted on the topic of FRP-RC compression members. In light of this, eight glass-fiber-reinforced polymer (GFRP)-RC square columns (200×200×600 mm) were tested in order to investigate their axial compression performance. These columns were reinforced with GFRP longitudinal reinforcement and confined GFRP stirrup. These experiments investigated the effects of the longitudinal reinforcement ratio, stirrup configuration (spirals versus hoops) and spacing on the load-carrying capacity and failure modes of GFRP-RC rectangular columns. The test results indicate that the load-carrying capacity of longitudinal GFRP bars accounted for 3%-7% of the ultimate load-carrying capacity of the columns. The ultimate load-carrying capacity of RC columns confined with GFRP spirals increased by 0.8%-1.6% with higher ductility, compared to GFRP hoops. Reducing the stirrup spacing may prevent the buckling failure of the longitudinal bars and increase the ductility and load-carrying capacity of the GFRP-RC columns. It has been found that setting the GFRP compressive strength to 35% of the GFRP maximum tensile strength yields a reasonable estimate of ultimate load-carrying capacity of GFRP-RC columns.


2003 ◽  
Vol 1845 (1) ◽  
pp. 191-199 ◽  
Author(s):  
Ondrej Kalny ◽  
Robert J. Peterman ◽  
Guillermo Ramirez ◽  
C. S. Cai ◽  
Dave Meggers

Stiffness and ultimate load-carrying capacities of glass fiber-reinforced polymer honeycomb sandwich panels used in bridge applications were evaluated. Eleven full-scale panels with cross-section depths ranging from 6 to 31.5 in. (152 to 800 mm) have been tested to date. The effect of width-to-depth ratio on unit stiffness was found to be insignificant for panels with a width-to-depth ratio between 1 and 5. The effect of this ratio on the ultimate flexural capacity is uncertain because of the erratic nature of core-face bond failures. A simple analytical formula for bending and shear stiffness, based on material properties and geometry of transformed sections, was found to predict service-load deflections within 15% accuracy. Although some factors influencing the ultimate load-carrying capacity were clearly identified in this study, a reliable analytical prediction of the ultimate flexural capacity was not attained. This is because failures occur in the bond material between the outer faces and core, and there are significant variations in bond properties at this point due to the wet lay-up process, even for theoretically identical specimens. The use of external wrap layers may be used to shift the ultimate point of failure from the bond (resin) material to the glass fibers. Wrap serves to strengthen the relatively weak core–face interface and is believed to bring more consistency in determining the ultimate load-carrying capacity.


1987 ◽  
Vol 2 (3) ◽  
pp. 77-80 ◽  
Author(s):  
Marvin R. Pyles ◽  
Joan Stoupa

Abstract In order to quantify the stump anchor capacity of small second-growth Douglas-fir (Pseudotsuga menziesii [Mirb]. Franco) trees, load tests to failure were conducted on 18 stumps from trees 7 to 16.5 in dbh. The tests produced ultimate loads that varied as the square of the tree diameter. However, the ultimate load typically occurred at stump system deformations that were far in excess of that which would be considered failure of a stump anchor. A hyperbolic equation was used to describe the load-deformation behavior of each stump tested and was generalized to describe all the test results. West. J. Appl. For. 2(3):72-80, July 1987.


2019 ◽  
Vol 22 (13) ◽  
pp. 2755-2770
Author(s):  
Fuyun Huang ◽  
Yulong Cui ◽  
Rui Dong ◽  
Jiangang Wei ◽  
Baochun Chen

When casting wet concrete into hollow steel tubular arch during the construction process of a concrete-filled steel tubular arch bridge, an initial stress (due to dead load, etc.) would be produced in the steel tube. In order to understand the influence of this initial stress on the strength of the concrete-filled steel tubular arch bridge, a total of four single tubular arch rib (bare steel first) specimens (concrete-filled steel tubular last) with various initial stress levels were constructed and tested to failure. The test results indicate that the initial stress has a large influence on the ultimate load-carrying capacity and ductility of the arch structure. The high preloading ratio will reduce significantly the strength and ductility that the maximum reductions are over 25%. Then, a finite element method was presented and validated using the test results. Based on this finite element model, a parametric study was performed that considered the influence of various parameters on the ultimate load-carrying capacity of concrete-filled steel tubular arches. These parameters included arch slenderness, rise-to-span ratio, loading method, and initial stress level. The analysis results indicate that the initial stress can reduce the ultimate loading capacity significantly, and this reduction has a strong relationship with arch slenderness and rise-to-span ratio. Finally, a method for calculating the preloading reduction factor of ultimate load-carrying capacity of single concrete-filled steel tubular arch rib structures was proposed based on the equivalent beam–column method.


Sign in / Sign up

Export Citation Format

Share Document