Noninvasive Alcohol Detection Using Near-Infrared Spectroscopy Based on Partial Least Squares and Monte-Carlo

2012 ◽  
Vol 229-231 ◽  
pp. 1308-1311
Author(s):  
Si Te Luo ◽  
Guo Qiang Chen ◽  
Ruo Fei Cui ◽  
Wei Wei Zhou ◽  
Li Qian Lu ◽  
...  

The objective of this study was to assess the feasibility of noninvasive alcohol testing in vivo with near-infrared (NIR) spectroscopy. The suitable distance between light source and detector was determined by Monte-Carlo simulation. The NIR spectra signals of alcohol in vitro and in vivo were measured, and the blood alcohol concentration (BAC) was measured with breath test method. Wavelet de-noising and partial least squares (PLS) method were used to establish the quantitative calibration model of alcohol. The results indicate that alcohol spectra had two absorption peaks at range of 2200nm~2400nm. The optimal principal component number of PLS model is 3, RMSEP=9.29, MREP=3.5%,R=0.9802. The model has good prediction accuracy. NIRS might provide a new method to the measurement of alcohol in vivo.

2019 ◽  
Vol 5 (1) ◽  
pp. 10 ◽  
Author(s):  
Ahmed Rady ◽  
Daniel Guyer ◽  
William Kirk ◽  
Irwin R Donis-González

The sprouting of potato tubers during storage is a significant problem that suppresses obtaining high quality seeds or fried products. In this study, the potential of fusing data obtained from visible (VIS)/near-infrared (NIR) spectroscopic and hyperspectral imaging systems was investigated, to improve the prediction of primordial leaf count as a significant sign for tubers sprouting. Electronic and lab measurements were conducted on whole tubers of Frito Lay 1879 (FL1879) and Russet Norkotah (R.Norkotah) potato cultivars. The interval partial least squares (IPLS) technique was adopted to extract the most effective wavelengths for both systems. Linear regression was utilized using partial least squares regression (PLSR), and the best calibration model was chosen using four-fold cross-validation. Then the prediction models were obtained using separate test data sets. Prediction results were enhanced compared with those obtained from individual systems’ models. The values of the correlation coefficient (the ratio between performance to deviation, or r(RPD)) were 0.95(3.01) and 0.9s6(3.55) for FL1879 and R.Norkotah, respectively, which represented a feasible improvement by 6.7%(35.6%) and 24.7%(136.7%) for FL1879 and R.Norkotah, respectively. The proposed study shows the possibility of building a rapid, noninvasive, and accurate system or device that requires minimal or no sample preparation to track the sprouting activity of stored potato tubers.


2020 ◽  
Vol 38 (No. 2) ◽  
pp. 131-136
Author(s):  
Wojciech Poćwiardowski ◽  
Joanna Szulc ◽  
Grażyna Gozdecka

The aim of the study was to elaborate a universal calibration for the near infrared (NIR) spectrophotometer to determine the moisture of various kinds of vegetable seeds. The research was conducted on the seeds of 5 types of vegetables – carrot, parsley, lettuce, radish and beetroot. For the spectra correlation with moisture values, the method of partial least squares regression (PLS) was used. The resulting qualitative indicators of a calibration model (R = 0.9968, Q = 0.8904) confirmed an excellent fit of the obtained calibration to the experimental data. As a result of the study, the possibilities of creating a calibration model for NIR spectrophotometer for non-destructive moisture analysis of various kinds of vegetable seeds was confirmed.<br /><br />


2000 ◽  
Vol 54 (2) ◽  
pp. 294-299 ◽  
Author(s):  
Songbiao Zhang ◽  
Babs R. Soller ◽  
Shubjeet Kaur ◽  
Kristen Perras ◽  
Thomas J. Vander Salm

Hematocrit (Hct), the volume percent of red cells in blood, is monitored routinely for blood donors, surgical patients, and trauma victims and requires blood to be removed from the patient. An accurate, noninvasive method for directly measuring hematocrit on patients is desired for these applications. The feasibility of noninvasive hematocrit measurement by using near-infrared (NIR) spectroscopy and partial least-squares (PLS) techniques was investigated, and methods of in vivo calibration were examined. Twenty Caucasian patients undergoing cardiac surgery on cardiopulmonary bypass were randomly selected to form two study groups. A fiber-optic probe was attached to the patient's forearm, and NIR spectra were continuously collected during surgery. Blood samples were simultaneously collected and reference Hct measurements were made with the spun capillary method. PLS multivariate calibration techniques were applied to investigate the relationship between spectral and Hct changes. Single patient calibration models were developed with good cross-validated estimation of accuracy (∼ 1 Hct%) and trending capability for most patients. Time-dependent system drift, patient temperature, and venous oxygen saturation were not correlated with the hematocrit measurements. Multi-subject models were developed for prediction of independent subjects. These models demonstrated a significant patient-specific offset that was shown to be partially related to spectrometer drift. The remaining offset is attributed to the large spectral variability of patient tissue, and a significantly larger set of patients would be required to adequately model this variability. After the removal of the offset, the cross-validated estimation of accuracy is 2 Hct%.


2020 ◽  
Author(s):  
Elise Ai Hwee Kho ◽  
Jill N. Fernandes ◽  
Andrew C. Kotze ◽  
Glen P. Fox ◽  
Maggy T. Sikulu-Lord ◽  
...  

Abstract Background: Existing diagnostic methods for the parasitic gastrointestinal nematode, Haemonchus contortus, are time consuming and require specialised expertise, limiting their utility in the field. A practical, on-farm diagnostic tool could facilitate timely treatment decisions, preventing production and welfare loss in the flock. We previously demonstrated the ability of visible-near infrared (vis-NIR) spectroscopy to detect and quantify blood in sheep faeces with high accuracy. Here we investigate whether variation in sheep type and environment affect the prediction accuracy of vis-NIR spectroscopy in quantifying blood in faeces.Methods: Vis-NIR spectra were obtained from worm-free sheep faeces from different environments in South Australia (SA) and New South Wales (NSW), Australia and spiked with various sheep blood concentrations collected. Spectra were analysed using principal component analysis (PCA), and calibration models were built around the haemoglobin (Hb) wavelength region (387 – 609 nm) using partial least squares (PLS) regression. Models were used to predict Hb concentrations in spiked faeces from SA and naturally infected Queensland (QLD) faeces. Naturally occurring blood in QLD samples was quantified using Hemastix® and FAMACHA© scores.Results: PCA showed that location, class of sheep and pooled/individual samples were factors affecting the Hb predictions in sheep faeces. The calibration models successfully differentiated ‘healthy’ SA samples from those requiring anthelmintic treatment with moderate to good prediction accuracy (sensitivity: 57 – 94%, specificity: 44 – 79%). The models were not predictive for naturally infected QLD samples, which may be due in part to variability of faecal background and blood chemistry between samples, or the difference in validation methods used for blood quantification. PCA of QLD samples, however, identified a difference between samples containing high and low quantities of blood.Conclusion: This study demonstrates the potential of vis-NIR spectroscopy for estimating blood concentration in faeces from various types of sheep and environmental backgrounds. However, the calibration models developed here did not capture enough environmental variation to accurately predict Hb in faeces collected from environments different to those used in the calibration model. Consequently, it will be necessary to establish models that incorporate samples that are more representative of areas where H. contortus is endemic for the accurate prediction of H. contortus infections in these regions.


2020 ◽  
Author(s):  
Elise Ai Hwee Kho ◽  
Jill N. Fernandes ◽  
Andrew C. Kotze ◽  
Glen P. Fox ◽  
Maggy T. Sikulu-Lord ◽  
...  

Abstract Background: Existing diagnostic methods for the parasitic gastrointestinal nematode, Haemonchus contortus, are time consuming and require specialised expertise, limiting their utility in the field. A practical, on-farm diagnostic tool could facilitate timely treatment decisions, preventing production and welfare loss in the flock. We previously demonstrated the ability of visible-near infrared (vis-NIR) spectroscopy to detect and quantify blood in sheep faeces with high accuracy. Here we investigate whether variation in sheep type and environment affect the prediction accuracy of vis-NIR spectroscopy in quantifying blood in faeces. Methods: Vis-NIR spectra were obtained from worm-free sheep faeces collected from different environments and sheep types in South Australia (SA) and New South Wales (NSW), Australia and spiked with various sheep blood concentrations. Spectra were analysed using principal component analysis (PCA), and calibration models were built around the haemoglobin (Hb) wavelength region (387 – 609 nm) using partial least squares (PLS) regression. Models were used to predict Hb concentrations in spiked faeces from SA and naturally infected sheep faeces from Queensland (QLD). QLD samples were quantified using Hemastix® and FAMACHA © scores. Results: PCA showed that location, class of sheep and pooled/individual samples were factors affecting the Hb predictions. The models successfully differentiated ‘healthy’ SA samples from those requiring anthelmintic treatment with moderate to good prediction accuracy (sensitivity: 57 – 94%, specificity: 44 – 79%). The models were not predictive for blood in naturally infected QLD samples, which may be due in part to variability of faecal background and blood chemistry between samples, or the difference in validation methods used for blood quantification. PCA of QLD samples, however, identified a difference between samples containing high and low quantities of blood. Conclusion: This study demonstrates the potential of vis-NIR spectroscopy for estimating blood concentration in faeces from various types of sheep and environmental backgrounds. However, the calibration models developed here did not capture enough environmental variation to accurately predict Hb in faeces collected from environments different to those used in the calibration model. Consequently, it will be necessary to establish models that incorporate samples that are more representative of areas where H. contortus is endemic.


2018 ◽  
Vol 26 (6) ◽  
pp. 398-405 ◽  
Author(s):  
Te Ma ◽  
Tetsuya Inagaki ◽  
Satoru Tsuchikawa

Near infrared hyperspectral imaging combined with partial least squares regression analysis was used to evaluate wood stiffness (modulus of elasticity) and fiber coarseness. Five samples with normal wood and compression wood collected from two Japanese Cedar ( Cryptomeria japonica) trees were analyzed. To achieve high reliability of the prediction values, a SilviScan system (X-ray densitometry, X-ray diffractometry, and optical microscopy) with the high spatial resolution was used for measuring reference data. The measurement interval for modulus of elasticity and fiber coarseness was 1 mm and 25 µm, respectively. After spectral pre-treatment and key wavelengths selection, partial least squares analysis was applied to calibrate near infrared data to reference values. The determination coefficient ( RCV2) of modulus of elasticity was 0.66 with a root mean square error of cross validation (RMSECV) of 1.80 GPa. For the constructed fiber coarseness calibration model, RCV2 and RMSECV were 0.62 and 35.02 µm/g, respectively. Finally, modulus of elasticity and fiber coarseness mapping results show detailed information (156 µm/pixel) at the grown ring level. The differences among earlywood, latewood, and compression wood were all well identifiable.


Foods ◽  
2020 ◽  
Vol 9 (6) ◽  
pp. 827
Author(s):  
Najeeb Ur Rehman ◽  
Ahmed Al-Harrasi ◽  
Ricard Boqué ◽  
Fazal Mabood ◽  
Muhammed Al-Broumi ◽  
...  

Daily consumption of caffeine in coffee, tea, chocolate, cocoa, and soft drinks has gained wide and plentiful public and scientific attention over the past few decades. The concentration of caffeine in vivo is a crucial indicator of some disorders—for example, kidney malfunction, heart disease, increase of blood pressure and alertness—and can cause some severe diseases including type 2 diabetes mellitus (DM), stroke risk, liver disease, and some cancers. In the present study, near-infrared spectroscopy (NIRS) coupled with partial least-squares regression (PLSR) was proposed as an alternative method for the quantification of caffeine in 25 commercially available tea samples consumed in Oman. This method is a fast, complementary technique to wet chemistry procedures as well as to high-performance liquid chromatography (HPLC) methods for the quantitative analysis of caffeine in tea samples because it is reagent-less and needs little or no pre-treatment of samples. In the current study, the partial least-squares (PLS) algorithm was built by using the near-infrared NIR spectra of caffeine standards prepared in tea samples scanned by a Frontier NIR spectrophotometer (L1280034) by PerkinElmer. Spectra were collected in the absorption mode in the wavenumber range of 10,000–4000 cm−1, using a 0.2 mm path length and CaF2 sealed cells with a resolution of 2 cm−1. The NIR results for the contents of caffeine in tea samples were also compared with results obtained by HPLC analysis. Both techniques provided good results for predicting the caffeine contents in commercially available tea samples. The results of the proposed study show that the suggested FT-NIRS coupled with PLS regression algorithun has a high potential to be routinely used for the quick and reproducible analysis of caffeine contents in tea samples. For the NIR method, the limit of quantification (LOQ) was estimated as 10 times the error of calibration (root mean square error of calibration (RMSECV)) of the model; thus, RMSEC was calculated as 0.03 ppm and the LOQ as 0.3 ppm.


2003 ◽  
Vol 57 (2) ◽  
pp. 146-151 ◽  
Author(s):  
Babs R. Soller ◽  
Janice Favreau ◽  
Patrick O. Idwasi

The feasibility of using near-infrared (NIR) spectroscopy in combination with partial least-squares (PLS) regression was explored to measure electrolyte concentration in whole blood samples. Spectra were collected from diluted blood samples containing randomized, clinically relevant concentrations of Na+, K+, and Ca2+. Sodium was also studied in lysed blood. Reference measurements were made from the same samples using a standard clinical chemistry instrument. Partial least squares (PLS) was used to develop calibration models for each ion with acceptable results (Na+, R2 = 0.86, CVSEP = 9.5 mmol/L; K+, R2 = 0.54, CVSEP = 1.4 mmol/L; Ca2+, R2 = 0.56, CVSEP = 0.18 mmol/L). Slightly improved results were obtained using a narrower wavelength region (470–925 nm) where hemoglobin, but not water, absorbed indicating that ionic interaction with hemoglobin is as effective as water in causing measurable spectral variation. Good models were also achieved for sodium in lysed blood, illustrating that cell swelling, which is correlated with sodium concentration, is not required for calibration model development.