Low Strength Self Compacting Concrete Compressive Strength Test

2013 ◽  
Vol 275-277 ◽  
pp. 2041-2044
Author(s):  
Feng Yan ◽  
Nan Pang

In this paper,the mechanical properties were studied,the self compacting concrete cubic compression strength,prismatic compressive strength test,discussed two kinds of relationship between intensity index.

2018 ◽  
Vol 4 (4) ◽  
pp. 776 ◽  
Author(s):  
Mushtaq Ahmad ◽  
Sana Ullah ◽  
Aneel Manan ◽  
Temple Chimuanya Odimegeu ◽  
Salmia Beddu

The study has conducted to determine the workability and compressive strength of the self –compacting concrete. The sand has replaced with quarry dust with the proportion of 10, 20, 30 and 40% and super plasticizer was added 0.9%. The experiments were carried out at the Infrastructure University Kuala Lumpur (IUKL) concrete laboratory. Slump flow, J- Ring tests were carried out to determine the workability of self-compacting concrete and compressive strength test was conducted on 7 days and 28th days of curing period. A finding of the study shows that workability and compressive strength has increased by addition of quarry dust. It is concluded that addition of quarry dust up to 30%  improve the workability of the self-compacting concrete and further addition of quarry dust decrease the workability. Additionally, compressive strength of the quarry dust modified self-compacting concrete shows the trend of higher compressive strength up to 30% addition of quarry dust with sand replacement and further addition decrease the compressive strength.


2018 ◽  
Author(s):  
erniati

Self Compacting Concrete (SCC) is one solution to get concrete construction which it has good resistance. Durability of concrete was obtained by the good concrete compaction to be done by a skilled workforce. However, one of the negligence that often occur in the field ie after casting they was ignoring curing of the hardening concrete. This study discusses the workability of fresh concrete and mechanical properties (compressive strength and splitting tensile strength) on SCC without curing. Testing of the concrete workability based on EFNARC standard. The mechanical properties test based on ASTM standards. The method Compressive strength test based on ASTM standards 39 / C 39M - 12a, whereas splitting tensile strength accordance standard ASTM C496 / C496M-11. The results of the study indicate that the SCC without curing effect on the reduction in compressive strength at ages 1, 3, 7, 28, and 90 days in a row at 4.11 MPa (16.1%); 4.90 MPa (13.9%); 6.64 MPa (13.1%); and 6, 72 MPa (12.75%). Splitting tensile strength decreased respectively by 0.1 MPa (3.25%); 0.26 MPa (7.99%); 0.4 MPa (9.52%); and 0.39 MPa (9.16%).


UKaRsT ◽  
2018 ◽  
Vol 2 (1) ◽  
pp. 10
Author(s):  
Nur Affandy ◽  
Zulkifli Lubis

This research will be conducted in accordance with Indonesian Standard SK SNI and foreign standard ASTM. The test object consists of a cylindrical test with the diameter of 15 cm and a height of 30 cm, and it is developed to 4 mixture variations with the amount of 2%, 4%, 6%, 8%, of total cement. The mechanical properties of concrete is being tested include concrete compressive strength. Itis tested at the age of 7 days, and then converted at 28 days, using test objects mixed with different fiber variations. The results of the test are: compressive strength test with 2% variation is 7,54MPa, compressive strength testwith 4% variation is 6,74 Mpa, compressive strength with 6% variation is 4,58 Mpa, compressive strength with 8% variation is 3.63 MPa. Maximum concrete compressive strength occurs in 2% fiber  mixture, while the minimum concrete compressive strength occurs in 8%. From these results, it can be concluded that the addition of water hyacinth fiber to the mixture for low quality concrete has not been able to increase its compressive strength.Keywords: Fiber, Water Hyacinth, Concrete Compressive Strength.


2018 ◽  
Author(s):  
Erniati Bachtiar

Self Compacting Concrete (SCC) is one solution to get concrete construction which it has good resistance. Durability of concrete was obtained by the good concrete compaction to be done by a skilled workforce. However, one of the negligence that often occur in the field ie after casting they was ignoring curing of the hardening concrete. This study discusses the workability of fresh concrete and mechanical properties (compressive strength and splitting tensile strength) on SCC without curing. Testing of the concrete workability based on EFNARC standard. The mechanical properties test based on ASTM standards. The method Compressive strength test based on ASTM standards 39 / C 39M - 12a, whereas splitting tensile strength accordance standard ASTM C496 / C496M-11. The results of the study indicate that the SCC without curing effect on the reduction in compressive strength at ages 1, 3, 7, 28, and 90 days in a row at 4.11 MPa (16.1%); 4.90 MPa (13.9%); 6.64 MPa (13.1%); and 6, 72 MPa (12.75%). Splitting tensile strength decreased respectively by 0.1 MPa (3.25%); 0.26 MPa (7.99%); 0.4 MPa (9.52%); and 0.39 MPa (9.16%).


2019 ◽  
Vol 3 (2) ◽  
pp. 81-89
Author(s):  
Angga Pirman Firdaus ◽  
Jonbi

Indonesia ranks second in the world's largest plastic waste producer after China. Each year, Indonesia can contributeup to 187.2 million tons of plastic waste, while China reaches 262.9 million tons of plastic waste. Based on the data, one way to utilize plastic waste by using plastic waste as a mixture of concrete, where the plastic used is polypropylene (PP) plastic with different percentage of concrete mixture, the test includes compressive strength test and tensile concrete. The results of concrete compressive strength testing with polypropylene (PP) plastic waste mixture of 5%, 10% and 15% at age 28 in aggregate aggregate mixture decreased by 5.15%, 6.89% and 13.53%. As for the result of concrete tensile strength test with polypropylene (PP) plastic waste mixture of 5%, 10% and 15% at age 28 in crude aggregate mixture decreased 17,61%, 24,13% dan 23,24%.


2019 ◽  
Vol 801 ◽  
pp. 436-441
Author(s):  
Shin Jen Chen ◽  
Chao Shi Chen ◽  
Jyun Yong Jhan ◽  
Ruei Fu Chen

Controlled low-strength materials (CLSM) have begun to apply in a lot of countries because CLSM could distribute randomly in complex sites. Manufacturing from chlor-alkali industry, the brine sludge was used to replace the composition in CLSM for resource application. In this study, the mix composition of brine sludge replaced only the fine aggregates or all of the aggregates. Examining the suitable composition, the ball drop test and the compressive strength test were carried out. The ball drop test was applied to determine the readiness of the CLSM to accept loads prior, and the bearing capacity at different ages were measured by the compressive strength test. The results of the ball drop test in different replacements was 7 - 11.5 cm. The replacement of fine aggregates satisified the rule of CLSM. Replacing all of the aggregates, the mixtures were over 7.6 cm, which meant that the early strength at 1 day were not sufficient. The value of compressive strength at 28 days was 1.709 - 21.37 kgf/cm2, conforming the requirement of CLSM. Overall, the mixture which replaced the fine aggregates met all the specified values of CLSM. In particular, the composition of coarse aggregates reduce to 250 kg/m3, the utalization of the brine sludge could be the most.


2018 ◽  
Author(s):  
Erniati Bachtiar

Concrete construction technology is directed to be sustainable and ecofriendly. The waste of the candlenut shell as a substitute for the coarse aggregate of concrete mixture is known that the candlenut shell has a hard texture so it may be used as a substitute for coarse aggregates in concrete. The purpose of the research was to determine the effect of Candlenut shell as a substitute of coarse aggregate on physical properties (slump test, bleeding, segregation, volume weight) and mechanical properties (compressive strength and tensile strength) of concrete using Candlenut shell as replacement material of the coarse aggregate. The variation of the research was percentage of the Candlenut shell in the concrete mixture, that was 0%, 25%, 50%, 75% and 100% to the coarse aggregate volume in the concrete mixture. Number of specimens in reseach was each 5 pieces each variation. Testing of mechanical properties of concrete (compressive strength and tensile strength) was performed at 28 days. Testing of the concrete for compressive strength test and tensile strength on age 28 days. Concrete using candlenut shell as a substitute of coarse aggregates has decreased compressive strength respectively 11.72 MPa (37.71%) for 25% candlenut shell; 15.54 MPa (50.00%) for 50% candlenut shell; 18.35 MPa (59.02%) for 75% candlenut shell; And 18,85 MPa (60,66%) for 100% candlenut shell from of the 0% candlenut shell with compressive strength of 31.08 Mpa. Concrete using for 25% candlenut shell as a substitute for coarse aggregates decreased tensile strength respectively of 0.95 MPa (28.70%) for 25% candlenut shell; 1.21 MPa (36.56%) for 50% candlenut shell; 1.27 MPa (38.37%) for 75% candlenut shell; And 1.40 MPa (42.30%) for 100% candlenut shell from of the 0% candlenut shell with the tensile strength of BN of 3.31 MPa. The decrease in the value of compressive strength and tensile strength is strongly influenced by the increasing percentage of Candlenut shells on concrete


2019 ◽  
Vol 803 ◽  
pp. 228-232
Author(s):  
Samer Al Martini ◽  
Ziad Hassan ◽  
Ahmad Khartabil

The current study investigates the effect of aggregate’s maximum size on the compressive strength of sustainable flowable concrete. The concrete mixtures were mixed for 2 hours under lab controlled environment. The purpose of the prolonged mixing was to simulate concrete in a transit truck during transportation to a construction site. The mechanical properties of the mixes were investigated through compressive strength test. Three groups of concrete mixes were prepared: the first one with 20 mm maximum size aggregates, the second group with 10 mm maximum size aggregates and third group with 5 mm max size. The concrete mixes incorporated GGBs and fly ash (FA) in binary blends. To maintain consistent initial slump for all mixes, polycarboxylate based high-range water-reducing admixture (HRWR) was used. The concrete compressive strength was measured at 1, 3, 7, and 28 days. The results showed that the mechanical properties of sustainable flow mixtures investigated were highly affected by FA, GGBS, and maximum size aggregates.