Application of Interferometry Measurement in Large-Scale Optic-Electrical Theodolite

2013 ◽  
Vol 303-306 ◽  
pp. 335-338
Author(s):  
Nan Zhao ◽  
Zhi Yuan Sun

Interferometry is a very important method in high accuracy measurement for optical system. This article briefly introduced the conception of interferometry and took a product of 4D Technology as an example to carry on the measurement. A large-scale optic-electrical Theodolite in assemblage was measured, and its primary mirror was 400mm in diameter. With the analysis of the results, some micro adjustments of the mechanical structure proceed, and it made the system perform better. The final results of the whole system is 1.061λ in P-V value and 0.1136λ in RMS value (λ=632.8nm), this meets the demand of optical design and practical application. The result demonstrates that interferometry is a good way to be utilized and optimize in the procedure of assemble.

2021 ◽  
Vol 46 (20) ◽  
pp. 5207
Author(s):  
K. Miao ◽  
J. W. Zhang ◽  
X. L. Sun ◽  
S. G. Wang ◽  
A. M. Zhang ◽  
...  

Author(s):  
Azzeddine Ferrah ◽  
Mounir Bouzguenda ◽  
Jehad M. Al-Khalaf Bani Younis

Large and small single-phase and three-phase induction motors are commonly used in industrial applications. The present work represents an attempt towards the design of a high accuracy system for the measurement of fractional horsepower (FHP) induction motor losses and efficiency. The calorimeter designed and built is capable of measuring heat losses of up to 1 kW with an overall accuracy better than 3%. During all tests, ambient temperature, humidity, motor speed and motor frame temperature were recorded using precise digital instruments. The inlet, outlet temperatures and resulting losses were recorded automatically using a high accuracy 12-bit data acquisition system. The preliminary results obtained demonstrate the suitability of the designed calorimeter for the accurate measurement of losses in FHP induction motors.


2021 ◽  
Vol 2112 (1) ◽  
pp. 012007
Author(s):  
Chong Song ◽  
Yong Huang ◽  
Yangdong Yan ◽  
Dongsen Cui ◽  
Gang Wang ◽  
...  

Abstract An improved Offner imaging spectrometer was proposed based on the optical system characteristics of Offner imaging spectrometer, which can ensure perfect imaging quality in a wider annular region. The operating wavelength of the improved Offner imaging spectrometer ranges from 900nm to 1700nm, and the magnification is 1. Improved Offner imaging spectrometer can be obtained by changing the meniscus lens position and further optimizing the design. The results indicate that the improved Offner imaging spectrometer can effectively improve compactness and lightweight, and reduce the difficulty of optical adjustment, which is conducive to the stability of practical application.


2018 ◽  
Vol 47 (9) ◽  
pp. 906008
Author(s):  
孙兴伟 Sun Xingwei ◽  
于欣玉 Yu Xinyu ◽  
董祉序 Dong Zhixu ◽  
杨赫然 Yang Heran

Sign in / Sign up

Export Citation Format

Share Document