Study and Progress for RBC in Biological Wastewater Treatment

2014 ◽  
Vol 1030-1032 ◽  
pp. 317-321
Author(s):  
Fu Jun Liu ◽  
Hua Zeng

RBC is one of the effective actors in wastewater treatment. From the fundamental characteristics and treating principle of RBC, this article compares different type of RBC ,includes discussions concerning the progress of RBC’s application、the practical applications and it’s affective factor, then takes a long view of the prospect on studying of RBC on the basis of the discussion in the forward part. Key words: RBC(rotating biological contactor); domestic sewage; industrial wastewater

2018 ◽  
Vol 22 (6) ◽  
pp. 20-25 ◽  
Author(s):  
I.Yu. Shlekova ◽  
A.I. Knysh

The use of industrial wastes as alternative adsorbents for wastewater treatment is proposed. The effective concentration of the adsorbent was determined experimentally. The results of a study of the intensification of biological wastewater treatment using activated carbon and a pulverized coke fraction are presented. The efficiency of treatment in terms of "chemical oxygen demand" during the intake of highly concentrated sewage sludge with the use of an alternative adsorbent averaged 85 %. In the biosorption system, the conservation of the species diversity of the biocenosis of activated sludge and its purifying ability was noted. In the biological treatment system, purification efficiency was recorded on average 16 % less and destabilization of the system as a whole. The carried out researches prove expediency of use of adsorbents, including production wastes, for intensification of biological wastewater treatment in aero tanks.


2018 ◽  
Vol 251 ◽  
pp. 03029 ◽  
Author(s):  
Tran Ha Quan ◽  
Elena Gogina ◽  
Tran Van Quang

All around the world, activated sludge is the classical and traditional biological wastewater treatment for municipal and industrial wastewater. With the development of social and technology, the concentration of pollutants has been increased, so the performance of the old wastewater treatment plants not guaranteed. Therefore, upgrade and reconstruction wastewater treatment system becomes the main task of protection environment, especially in the developing countries. Application biofilms in process biological wastewater treatment is one of technology method and it has many advantages. In the Sequencing Batch Reactor, the Mutag BioChip 25TM provides to the bacteria an optimal habitat at the surface area, increasing rate of Utilization of Substrates 20 – 30% and efficiency of organic matter removal from 10 – 15%.


2020 ◽  
Author(s):  
Boris Ksenofontov

The training manual sets out the theoretical and practical foundations of biological wastewater treatment in both natural and artificial conditions. For in-depth study of the fundamentals of biological wastewater treatment is quite detailed sections on the basics of Microbiology. Much attention is paid to choosing the best technologies of biological wastewater treatment with effective methods of nutrient removal. In the expanded version of the methods of biological purification of wastewater using membrane bioreactors. Are extensively explored domestic and foreign experience of biological treatment of municipal and industrial wastewater. Meets the requirements of Federal state educational standards of higher education of the last generation. Intended for students of bachelor, master, PhD students, teachers and professionals interested in the methods of sewage purification, and it is recommended to study for the enlarged group of specialties and areas 20.00.00 "Technosphere safety and environmental engineering".


2010 ◽  
Vol 13 (3) ◽  
pp. 54-66
Author(s):  
Phuong Thi Thanh Nguyen ◽  
Phuoc Van Nguyen ◽  
Anh Cam Thieu

This study was performed to evaluate the efficiency of tapioca processing wastewater treatment using aerobic biofilter with variety of biofilter media: coir, coal, PVC plastic and Bio - Ball BB15 plastic. Research results in the lab demonstrated all four aerobic biofilter models processed can treated completely N and COD which COD reached 90-98% and N reached 61-92%, respectively, at the organic loading rates in range of 0.5, 1, 1.5 and 2 kgCOD/m3.day. The results identified coir filter was the best in four researched materials with removal COD and specific substract utilization rate can reach 98%, and 0.6 kg COD/kgVSS.day. Research results open the new prospects for the application of the cheap materials, available for wastewater treatment.


2016 ◽  
Vol 15 (3) ◽  
pp. 521-526
Author(s):  
Narcis Barsan ◽  
Mariana Turcu ◽  
Emilian Mo.negu.u ◽  
Mihaela Dascalu ◽  
Dana Chitimus ◽  
...  

1989 ◽  
Vol 21 (2) ◽  
pp. 189-193 ◽  
Author(s):  
B. Rigden

The design of a reverse osmosis desalination unit and a rotating biological contactor for water and wastewater treatment for a small island resort is described. Some operational data are presented and recommendations for design flows and loadings are made.


1994 ◽  
Vol 30 (5) ◽  
pp. 87-95 ◽  
Author(s):  
Susan E. Murcott ◽  
Donald R. F. Harleman

In the past decade, the development of polymers and new chemical technologies has opened the way to using low doses of chemicals in wastewater treatment. “Chemical upgrading” (CU) is defined in this paper as an application of these chemical technologies to upgrade overloaded treatment systems (typically consisting of conventional primary plus biological treatment) in Central and Eastern European (CEE) countries. Although some of the chemical treatment technologies are proven ones in North America, Scandinavia, and Germany, a host of factors, for example, the variations in composition and degree of pollution, the type of technologies in use, the type and mix of industrial and domestic sewage, and the amount of surface water, had meant that the viability of using CU in CEE countries was unknown. This report describes the first jar tests of CU conducted during the summer of 1993. The experiments show CU's ability to improve wastewater treatment plant performance and to potentially assist in the significant problem of overloaded treatment plants. Increased removal of BOD, TSS, and P in the primary stage of treatment is obtained at overflow rates above 1.5 m/h, using reasonably priced, local sources of metal salts in concentrations of 25 to 50 mg/l without polymers.


1995 ◽  
Vol 32 (7) ◽  
pp. 135-142
Author(s):  
E. Görgün ◽  
N. Artan ◽  
D. Orhon ◽  
R. Tasli

Effective nitrogen removal is now required to protect water quality in sensitive coastal areas. This involves a much more difficult treatment process than for conventional domestic sewage as wastewater quantity and quality exhibits severe fluctuations in touristic zones. Activated sludge is currently the most widely used wastewater treatment and may be upgraded as a predenitrification system for nitrogen removal. Interpretation of nitrification and denitrification kinetics reveal a number of useful correlations between significant parameters such as sludge age, C/N ratio, hydraulic retention time, total influent COD. Nitrogen removal potential of predenitrification may be optimized by careful evaluation of wastewater character and the kinetic correlations.


Sign in / Sign up

Export Citation Format

Share Document