Strain Rate Effect on Transmission Tower-Line System under Earthquake

2011 ◽  
Vol 243-249 ◽  
pp. 5845-5848
Author(s):  
Wen Ming Wang ◽  
Hong Nan Li ◽  
Guo Huan Liu ◽  
Li Tian

Using ABAQUS software, three dimensional finite element model of a transmission tower-line system is created. Nonlinear seismic responses under three seismic records with and without strain rate effect are studied. The results show that the strain rate effect on the transmission tower-line system is more obvious with an increase in intensity of the earthquake. The influence of strain rate on the top displacement and base shear of tower under certain seismic records is unneglectable. Also, it is shown that the strain rate effect on the deformation of wire is prominent. The strain rate effect on the axial force of wire is neglectable. This simple study reveals the importance of considering strain rate effect in seismic analysis for transmission tower-line system.

2014 ◽  
Vol 2014 ◽  
pp. 1-10
Author(s):  
Li Tian ◽  
Wenming Wang ◽  
Hui Qian

The effect analysis of strain rate on power transmission tower-line system under seismic excitation is studied in this paper. A three-dimensional finite element model of a transmission tower-line system is created based on a real project. Using theoretical analysis and numerical simulation, incremental dynamic analysis of the power transmission tower-line system is conducted to investigate the effect of strain rate on the nonlinear responses of the transmission tower and line. The results show that the effect of strain rate on the transmission tower generally decreases the maximum top displacements, but it would increase the maximum base shear forces, and thus it is necessary to consider the effect of strain rate on the seismic analysis of the transmission tower. The effect of strain rate could be ignored for the seismic analysis of the conductors and ground lines, but the responses of the ground lines considering strain rate effect are larger than those of the conductors. The results could provide a reference for the seismic design of the transmission tower-line system.


2016 ◽  
Vol 16 (07) ◽  
pp. 1550030 ◽  
Author(s):  
Li Tian ◽  
Rui-sheng Ma ◽  
Hong-nan Li ◽  
Yang Wang

The simulation of progressive collapse of a power transmission tower-line system subjected to extremely strong earthquakes is studied in this paper. A three-dimensional finite element model is established for the coupled system that combines three towers and four span lines based on a practical project. The birth to death technique is adopted to simulate the progressive collapse of the system by using the user subroutine VUMAT in ABAQUS. The simulation of progressive collapse of the transmission tower-line system under either single-component or multi-component earthquake excitations is conducted. The collapse path, fracture position and collapse resistant capacity of the transmission tower are investigated. The result shows that the effect of multi-component seismic excitations should be taken into account in simulation of progressive collapse of the transmission tower, since the behavior of towers under multi-component excitations is different from that of single-component excitations. In addition, incremental dynamic analysis (IDA) is carried out to verify the results obtained herein. The present result should prove useful to the seismic design of power transmission towers.


2018 ◽  
Vol 22 (1) ◽  
pp. 30-41 ◽  
Author(s):  
Li Tian ◽  
Haiyang Pan ◽  
Canxing Qiu ◽  
Ruisheng Ma ◽  
Qiqi Yu

The collapse problem of transmission tower upon strong winds was well noted in past few years. This article analyses the wind-induced collapse problem of a long-span transmission tower–line system. The member buckling effect was particularly considered. In doing so, a three-dimensional finite element model of the long-span transmission tower–line system was established in ABAQUS based on a practical project. The transmission tower and line were simulated by the frame and truss elements, respectively. The nonlinear behavior of a compressive member was simulated using the Marshall model, and the nonconvergence of numerical calculation was set to be the collapse criterion. The critical wind speed, damage position, and collapse probability were obtained from a collapse analysis of the long-span transmission tower–line system under different wind attack angles. The collapse mechanism of the long-span transmission tower–line system under a wind attack angle of 45° was investigated, and an incremental dynamic analysis was performed to evaluate the collapse-resistant capacity of the transmission tower. The study reveals that the interaction between bending moment and shear deformation is critical to the collapse of transmission tower.


2021 ◽  
Vol 2021 ◽  
pp. 1-11
Author(s):  
Xianglong Li ◽  
Zihao Tao ◽  
Jianguo Wang ◽  
Ting Zuo ◽  
Jun Ma ◽  
...  

In order to study the influence of pillar stopping blasting on the stability of cemented backfill, the dynamic impact test under low strain rate (61.1∼86.8 s−1) was conducted on cemented backfill with two kinds of strength using three-dimensional coupled static-dynamic SHPB equipment. At the same time, the strain rate effect of failure mode, dynamic strength factor, and energy transfer of backfill were analyzed. The results show that when the cemented backfill was loaded under different strain rates in the initial three-dimensional static pressure environment, the pore compaction process was no longer obvious but directly entered the elastic deformation stage. Within the range of strain rates, the extreme value of dynamic intensity factor (DIF) of CTB230 was 6.8, while the extreme value of dynamic intensity factor of CTB310 specimen did not appear within the range of strain rates due to the improvement of the internal cementation force between particles. The fracture surfaces of specimens were perpendicular to the direction of load, and the failure mode was mainly the axial tensile failure, and the fracture surfaces were mostly close to the loading end. According to energy calculation, reflected energy accounts for 80.4%∼86.6% of incident energy; dissipated energy, 5.5%∼14.3%; transmitted energy, 5.3%∼7.9%.


2019 ◽  
Vol 3 (Special Issue on First SACEE'19) ◽  
pp. 207-2016
Author(s):  
Guillermo Martinez ◽  
David Castillo ◽  
José Jara ◽  
Bertha Olmos

This paper presents a first approximation of the seismic vulnerability of a sixteenth century building which is part of the historical center of Morelia, Mexico. The city was declared World Heritage by United Nations Educational, Scientific and Cultural Organization in 1991. The modeling and analysis of the building was carried out using a three-dimensional elastic tetrahedral finite elements model which was subjected to probabilistic seismic demands with recurrences of 500 yrs and 1000 yrs in addition to real seismic records. The model was able to correctly identify cracking pattern in different parts of the temple due to gravitational forces. High seismic vulnerability of the arched window and the walls of the middle part of the bell tower of the temple was indicated by the seismic analysis of the model.