The Numerical Study on the Environmentally Sustainable System - Ground-Source Heat Pump System

2011 ◽  
Vol 320 ◽  
pp. 530-535 ◽  
Author(s):  
Su Fen Li ◽  
Yan Shang ◽  
Di Chen

In this paper, the coupled thermal conduction and groundwater advection heat transfer model was developed according to the heat-transfer process between the heat exchanger underground and its ambient soil. Soil was considered as saturated porous medium. The paper analyzed that the influence of different inlet flow rate, inlet water temperature, and backfill material on the soil temperature field and heat exchange rate, compared the double U-tube and the single U-tube in numerical simulation. The results show that the enhancing of soil thermal conductivity, inlet water temperature and inlet water flow rate leads to the increase of the heat exchange rate of U tube heat exchanger, and the influence on the double U tube is relativity small. In addition, the heat exchange characteristic of the double U tube is superior to the single U tube. The result has guiding significance to the intermittent operation of the ground source heat pump.

Energies ◽  
2018 ◽  
Vol 11 (7) ◽  
pp. 1786 ◽  
Author(s):  
Sang Mu Bae ◽  
Yujin Nam ◽  
Byoung Ohan Shim

: A typical ground source heat pump (GSHP) system in South Korea has a ground heat exchanger (GHX) with a length of 100–150 m, which utilizes annually stable underground temperature to meet the loads of cooling, heating and hot water in buildings. However, most GSHP systems have been introduced in heating dominated areas because the system performance advantage is larger compared with air source heat pump system than that in cooling dominated areas. To effectively provide geothermal energy to the building in the limited urban area, it is necessary to install deep GHXs. Despite its large capacity, there are few studies on GSHP system with deep GHX over 300 m. In this study, to estimate the performance of the GSHP system with deep GHX and evaluate its feasibility, numerical simulation was conducted. To quantitatively analyze heat transfer between soil and GHX, the coupled model with GHX model and ground heat and groundwater transfer model was used. Furthermore, the heat exchange rate and the source temperature were calculated according to the operation modes, the length of GHX, and soil conditions such as geothermal gradient and thermal conductivity. As a result, the total heat exchange rate of GHX with a length of 300 m heat exchanger was 12.62 kW, 173% that of a length of 150 m. Finally, it was found that the GSHP system with deep GHX has realistic possibility in good condition of geothermal gradient.


2014 ◽  
Vol 529 ◽  
pp. 625-629
Author(s):  
Chao Yi Tan ◽  
Peng Fei Yang ◽  
Meng Meng Wang ◽  
Hai Hua Hu ◽  
Guo Qiang Zhang

In order to improve EER of the ground source heat pump system and reduce heat transfer area of the ground heat exchanger, the authors had developed a series connection ground source heat pump water chiller-heater unit, after theoretical analyses, proved that placing the water chilled in front of the hot water unit could acquire a higher EER comparing to the opposite. In the meantime, this unit had a higher EER than a common water chiller-heater unit or a water chiller-heater unit with condensing heat recovery device. In an air conditioning system of ground source heat pump, employing the above mentioned unit can also reduce heat transfer area of the ground heat exchanger. It suggested that series connection ground source heat pump water chiller-heater unit is a kind of technology with a great development potential.


Author(s):  
Masahito Oguma ◽  
Takeshi Matsumoto ◽  
Ayako Funabiki ◽  
Futoshi Miyaoka ◽  
Kosuke Ito ◽  
...  

A ground source heat pump (GSHP) system has higher cooling and heating performances than an air source heat pump system, so the GSHP system has attracted attention in the cold regions. Particularly after the 2011 earthquake off the Pacific coast of Tohoku, which damaged nuclear power plants, the GSHP utilizing renewable energy, has become attractive in heating system in the Tohoku region. However, it is necessary to install wells to collect ground source heat, and so, together with the cost of the heat pump itself, the installation cost is a barrier to widespread adoption of this technology in Japan. On the other hand, due to poor subsoil, foundation piles are often required in the construction of buildings in Japan. By using foundation piles as heat exchangers, which are commonly used in residential construction, the cost of using GSHP systems in houses may be reduced. However, since the placement of the piles depends on the floor layout of the residence, that is arbitrary sequence. Moreover, an arbitrary floor layout requires a complicated multi-dimensional numerical analysis to design the GSHP, and the analysis is burdensome for general designers. Therefore, the use of the model unit of the two-dimensional cylindrical heat exchange well is proposed. The use of this model, which includes an unused volume of soil, reduces the analysis burden for general design tools. On experience, the arrangement rate is 4 m2 per pile, and the well separation is narrow. And the foundation piles will form a group. So thermal interference between heat exchanger wells might be working hard. In addition, the foundation piles are very short, compared to the traditional borehole depth of 50 to 100 m. Therefore, the thermal performance of the well may degrade compared to that of the traditional GSHP system, although the initial costs are less. Therefore, we examined a GSHP system with heat exchanger piles by using the heat exchange well unit model for residences in the Tohoku region. As a result, the two-dimensional analysis and more is needed to predict the thermal performances of the heat exchanger piles so that the effect of the pitch of the heat exchange wells on the heat transfer in the axial direction will be large. In cold climates, the heating demand is large and, in the summer, the amount of waste heat to the ground is small, so a large amount of heat penetration into the ground from the atmospheric air is important for continuous GSHP operation in the Tohoku region, and in Fukushima Prefecture in particular.


Energies ◽  
2021 ◽  
Vol 14 (7) ◽  
pp. 1893
Author(s):  
Kwonye Kim ◽  
Jaemin Kim ◽  
Yujin Nam ◽  
Euyjoon Lee ◽  
Eunchul Kang ◽  
...  

A ground source heat pump system is a high-performance technology used for maintaining a stable underground temperature all year-round. However, the high costs for installation, such as for boring and drilling, is a drawback that prevents the system to be rapidly introduced into the market. This study proposes a modular ground heat exchanger (GHX) that can compensate for the disadvantages (such as high-boring/drilling costs) of the conventional vertical GHX. Through a real-scale experiment, a modular GHX was manufactured and buried at a depth of 4 m below ground level; the heat exchange rate and the change in underground temperatures during the GHX operation were tracked and calculated. The average heat exchanges rate was 78.98 W/m and 88.83 W/m during heating and cooling periods, respectively; the underground temperature decreased by 1.2 °C during heat extraction and increased by 4.4 °C during heat emission, with the heat pump (HP) working. The study showed that the modular GHX is a cost-effective alternative to the vertical GHX; further research is needed for application to actual small buildings.


2013 ◽  
Vol 724-725 ◽  
pp. 909-915
Author(s):  
Ping Fang Hu ◽  
Zhong Yi Yu ◽  
Fei Lei ◽  
Na Zhu ◽  
Qi Ming Sun ◽  
...  

A vertical U-tube ground heat exchanger can be utilized to exchange heat with the soil in ground source heat pump systems. The outlet temperature of the working fluid through the U-tube not only accounts for heat transfer capacity of a ground heat exchanger, but also greatly affects the operational efficiency of heat pump units, which is an important characteristic parameter of heat transfer process. It is quantified by defining a thermal effectiveness coefficient. The performance evaluation is performed with a three dimensional numerical model using a finite volume technique. A dynamic simulation was conducted to analyze the thermal effectiveness as a function of soil thermal properties, backfill material properties, separation distance between the two tube legs, borehole depth and flow velocity of the working fluid. The influence of important characteristic parameters on the heat transfer performance of vertical U-tube ground heat exchangers is investigated, which may provide the references for the design of ground source heat pump systems in practice.


Energies ◽  
2020 ◽  
Vol 13 (17) ◽  
pp. 4294
Author(s):  
Gaurav Shrestha ◽  
Mayumi Yoshioka ◽  
Hikari Fujii ◽  
Youhei Uchida

Evaluation of appropriate areas to introduce a closed-loop ground-source heat pump (GSHP) system in the case of a standard detached residence was conducted in Akita Plain, Japan. Depth of borehole heat exchanger (BHE) required to use a GSHP system was taken as the suitability index, which is simpler for the general public to understand and to promote the system. Heating and cooling loads of the standard size detached residence were calculated based on the 2013 Energy Conservation Standard. To estimate BHE depths and estimate a suitable area, identical 3D BHE models were constructed at 30 points in the plain. Required BHE depths were determined by performing heat exchange simulations at each location using the calculated loads and heat exchange rates. A suitability map showing distribution of the required BHE depths was prepared. BHE depths were shorter in the north-western area compared to the other parts, implying that the coastal lowlands in this area are more suitable for closed-loop system in the standard detached residences in terms of heat exchange performance as well as the cost reduction. Thickly distributed Quaternary System with higher thermal conductivity is contributing to shorter BHE depths. The suitability map is effective to adopt potential areas for the system installation in the standard detached Japanese residences.


2014 ◽  
Vol 945-949 ◽  
pp. 2820-2824 ◽  
Author(s):  
Li Bai ◽  
Peng Xuan Wang

For the case of ground-source heat pump in severe cold regions in winter, the heat transfer situation of the ground and ground heat exchanger was dynamically simulated according to the statistics of a project in Changchun to analysis the change of the ground heat, which provided references for the initial design and operation and management of the ground-coupled heat pump in severe cold regions.