Study on the Structural and Aseismatical Performance of Multi-Storey Ancient Chinese Timber Structure Shangyou Tower of Palace Style

2012 ◽  
Vol 535-537 ◽  
pp. 2012-2016
Author(s):  
Da Feng Gao ◽  
Peng Fei Li ◽  
Lei Wang

Based on the rich previous experimental data, the multi-storey ancient Chinese timber structure shangyou tower of palace style was studied. ANSYS10.0 software was used to establish the finite element models. One finite element model of large wooden frame was established by applying semi-rigid spring element to simulate the joint of mortise-tenon, tou-kung and the connection on column foot in the real wooden structure. The other finite element model of antique building corresponding to the finite element model above was established. The first 10 inherent frequencies and vibrations of the two models were obtained by the method of Block Lanczos with full transient analysis. The model displacement and acceleration time history curves were obtained by taking the two models subjected to El-Centro ground motion, Taft ground motion and Lanzhou artificial ground motion excitation. By the results analysis of the two models, it can be find that the vibration isolation performance of the ancient Chinese timber structure mainly manifests in the column foot, tenon and mortise connection and the tou-kung layer.

2012 ◽  
Vol 535-537 ◽  
pp. 2007-2011
Author(s):  
Da Feng Gao ◽  
Lei Wang ◽  
Peng Fei Li

In order to further study the seismic mechanism of ancient timber structure, the wooden structure of the temple was taken as the research object, and the reasonable mechanical model was established by applying semi-rigid spring element to simulate mortise-tenon joint, tou-kung and column base. The test of the compressive, bent and the shear capacity all met requirements by analyzing the model under the static load, and the average safety margin of the structure is 86.7%. The first six inherent frequencies and vibration shapes were obtained by analysing the finite element model using the method of Block Lanczos, With full transient analysis, considered the model in the El-Centro wave, Taft wave and Lanzhou artificial wave excitation under the three earthquake time history analysis, and got the model acceleration time history curves, the results show that the ancient Chinese timber structure has better aseismic performance. The above-mentioned methods and corresponding conclusions could provide the reference for maintenance and protection of ancient Chinese timber structure.


2019 ◽  
Vol 2019 ◽  
pp. 1-16 ◽  
Author(s):  
Halil Nohutcu

Historical structures are the values that are of great importance to that country, showing the roots of a country, and must be passed on from generation to generation. This study attempts to make a contribution to this goal. Seismic damage pattern estimation in a historical brick masonry minaret under different ground motion levels is investigated by using updated finite element models based on ambient vibration data in this study. Imaret Mosque which was built in 1481 AD is selected for an application. Surveying measurement and material tests were conducted to obtain a 3D solid model and mechanical properties of the components of the minaret. Firstly, the initial 3D finite element model of the minaret was analyzed and numerical dynamic characteristics of the minaret were obtained. Then, ambient vibration tests as well as operational modal analysis were implemented in order to obtain the experimental dynamic characteristics of the minaret. The initial finite element model of the minaret was updated by using the experimental dynamic results. Lastly, linear and nonlinear time-history analyses of the updated finite element model of the minaret were carried out using the acceleration records of two different level earthquakes that occurred in Turkey, in Afyon-Dinar (1995) and Çay-Sultandağı (2002). A concrete damage plasticity model is considered in the nonlinear analyses. The conducted analyses indicate that the compressive and tension stress results of the linear analyses are not as realistic as the nonlinear analysis results. According to the nonlinear analysis, the Çay-Sultandağı earthquake would inflict limited damage on the minaret, whereas the Dinar earthquake would damage some parts of the elements in the transition segment of the minaret.


2011 ◽  
Vol 368-373 ◽  
pp. 2586-2590
Author(s):  
Zhao Bo Meng ◽  
Shi Cai Cui ◽  
Teng Fei Zhao ◽  
Liu Qin Jin

According to measured shear wave velocity of Xi’an Bell Tower area (Loess Area), the dynamic parameters of site soil are determined by using the relationship between shear wave velocity and compression wave velocity. Using Matlab program, the finite element size for low frequency subway vibration is obtained by analyzing soil dispersion phenomenon. On this basis, two-dimensional model with viscous - elastic boundaries is established by using the ANSYS program. The load-time history of the train is applied to the right tunnel, and the effects of the depth and breadth of the different models on the ground vibration velocity are discussed. Finally, the dimensions and element sizes of finite element model are obtained for the Xi'an No. 2 Metro Line with 15m depth in the loess regions.


2014 ◽  
Vol 607 ◽  
pp. 405-408 ◽  
Author(s):  
Wen Liu ◽  
Teng Jiao Lin ◽  
Quan Cheng Peng

The gear-shaft-bearing-housing coupled finite element model of marine gearbox was established by using the truss element, the spring element and the tetrahedral element. The modal of gearbox was analyzed by using the ANSYS software. Then through the experimental modal analysis, the natural frequencies of gearbox are obtained. Compare the experimental results with the numerical results, it shows good agreement.


2000 ◽  
Vol 7 (6) ◽  
pp. 333-341 ◽  
Author(s):  
Lloyd Hammond ◽  
Raphael Grzebieta

This paper presents the results of a series of small-scale underwater shock experiments that measured the structural responses of submerged, fully clamped, air-backed, steel plates to a range of high explosive charge sizes. The experimental results were subsequently used to validate a series of simulations using the coupled LS-DYNA/USA finite element/boundary element codes. The modelling exercise was complicated by a significant amount of local cavitation occurring in the fluid adjacent to the plate and difficulties in modelling the boundary conditions of the test plates. The finite element model results satisfactorily predicted the displacement-time history of the plate over a range of shock loadings although a less satisfactory correlation was achieved for the peak velocities. It is expected that the predictive capability of the finite element model will be significantly improved once hydrostatic initialisation can be fully utilised with the LS-DYNA/USA software.


Author(s):  
Budy Notohardjono ◽  
Richard Ecker ◽  
Shawn Canfield

A mainframe computer’s structure consists of a frame or rack, drawers with central processor units, IO equipment, memory and other electronic equipment. The focus of this structural mechanical analysis and design is on the frame, earthquake stiffening brackets and tie-down methods. The primary function of the frame is to protect critical electronic equipment in two modes. The first mode is during shipping shock and vibration, which provides excitation primarily in the vertical direction. The second mode of protection is protecting the equipment during seismic events where horizontal vibration can be significant. Frame stiffening brackets and tie-downs are features added to mainframe systems that must meet earthquake resistance requirements. Designing to withstand seismic events requires significant analysis and test efforts since the functional performance of the system must be maintained during and after seismic events. The frame stiffening brackets and anchorage system must have adequate strength and stiffness to counteract earthquake-induced forces, thereby preventing human injury and potential system damage. The frame’s stiffening bracket and tie-down combination must ensure continued system operation by limiting overall displacement of the structure to acceptable levels, while not inducing undue stress to the critical electronic components. This paper discusses the process of finite element analysis and testing of a mainframe computer structure to develop a design that can withstand a severe earthquake test profile. Finite element analysis modeling tools such as ANSYS, a general-purpose finite element solver, was used to analyze the initial frame design CAD model. Both implicit and explicit finite element methods were used to analyze the mainframe subjected to uniaxial and triaxial earthquake test profiles. The seismic simulation tests involve extensive uniaxial and triaxial earthquake testing in both raised floor and non-raised floor environments at a test facility. Prior to this extensive final test, in-house tests were conducted along with modal analysis of the prototype frame hardware. These tests are used to refine the dynamic characteristics of the finite element model and to design the frame stiffening bracket and tie-down system. The purpose of the modeling and in-house testing is to have a verified finite element model of the server frame and components, which will then lead to successful, seismic system tests. During experimental verification, the dynamic responses were recorded and analyzed in both the time and frequency domains. The use of explicit finite element modeling, specifically LS-DYNA, extends the capability of implicit, linear modeling by allowing the incorporation of test data time history input and the experimentally derived damping ratio. When combined with the ability to model non-linear connections and material properties, this method provides better correlation to measured test results. In practice, the triaxial seismic time history was applied as input to the finite element model, which predicted regions of plastic strain and deformation. These results were used to iteratively simulate enhancements and successfully reduce structural failure in subsequent testing.


2005 ◽  
Vol 21 (4) ◽  
pp. 1009-1025 ◽  
Author(s):  
Andre Filiatrault ◽  
Howard Matt

This paper describes the shake table testing of a full-scale high-voltage electrical transformer-bushing system. The main objective of the study was to investigate the amplification between the ground motion and the motion at the base of the bushing under various ground-motion time histories and intensities. Another objective of the testing was to assess the predictions of a three-dimensional finite-element model of the transformer-bushing system. The experimental results obtained indicated that the rocking motion of the bushing and turret, facilitated by the top plate flexibility of the transformer, influenced significantly the dynamic characteristics of the bushing. The finite element model was able to predict absolute accelerations, relative displacements, and stress distributions in the systems with reasonable accuracy considering its complexity.


2014 ◽  
Vol 2014 ◽  
pp. 1-7 ◽  
Author(s):  
Chien-Chung Chen ◽  
Daniel G. Linzell

The objective of the work discussed herein is to develop a nonlinear 3D finite element model to simulate dynamic behavior of polyurea toughened steel plates under impact loading. Experimental and numerical work related to model development are presented. Material properties are incorporated into numerical models to account for strain-rate effects on the dynamic behavior of polyurea and steel. One bare steel plate and four polyurea toughened steel plates were tested under impact loading using a pendulum impact device. Displacement time-history data from experimental work was used to validate the numerical models. Details on material model construction, finite element model development, and model validation are presented and discussed. Results indicate that the developed numerical models can reasonably predict dynamic response of polyurea toughened steel plates under impact loading.


2011 ◽  
Vol 243-249 ◽  
pp. 116-119
Author(s):  
Tian Yin Xiao ◽  
Jian Gang Han ◽  
Hong Bo Gao

The aim of updating models is to generate improved numerical models which may be applied in order to predict actual dynamic behaviors of the structure. The approach of numerical predictions to the behavior of a physical system is limited by the assumptions used in the development of the mathematical model. Model updating is about correcting invalid assumptions by processing vibration test results. Updating by improving the physical meaning of the model requires the application of considerable physical insight in the choice of parameters to update and the arrangement of constraints, force inputs and response measurements in the vibration test. The choice of updating parameters is the most important and the numerical predictions should be sensitive to small changes in the parameters. So methods used in model updating places a demand that the mass, stiffness and damping terms should be based on physically meaningful parameters. Using the structure frequency and local modal shape acquired from structural time-history responses, a model updating method of space grid structures was established in this paper. A numerical example is provided to prove the accuracy of this method. The results show that the method can be effectively used to correct the finite element model of space grid structures.


Author(s):  
Jin Gan ◽  
Weiguo Wu ◽  
Jin Pan ◽  
Huanxiang Sun ◽  
Mengwei Zhu

In this paper, a new simplified finite element model is proposed for ship-jacket platform collision. This model can achieve all kinds of concerned parameters and time history curves through once calculation. This paper also discusses the effect of stain rate in ship-platform collision. On the basis of the above work, finite element numerical simulation of ship-platform collision is carried out. Some important results such as collision forces, stress, local deformations, distribution of various energies and displacement of platform are discussed. At last, some useful conclusions are achieved.


Sign in / Sign up

Export Citation Format

Share Document