Experimental Analysis on PV/T-SAHP Performance under the Influence of the Electronic Expansion Valve

2013 ◽  
Vol 641-642 ◽  
pp. 117-122
Author(s):  
Hai Tao Wang

Under different Electronic Expansion Valve (EXV)opening degree at the fixing frequency of 50hz of the compressor,we had test the system performance. When the cooling refrigerant influence to the PV module and the heating air influence to the collector/evaporator reached the balance,the photoelectric efficiency achieved the maximum.When the EXV opening degree fixing, with the raising of the solar radiation, the compressor power values appeared oscillation,and the oscillation was especially evident when the EXV at the maximum opening degree. So we put forward the PV/T-SAHP system stability principle.At the same time,we found that the key of the PV/T-SAHP research is to discover the relation between the solar radiation and the superheat of collector/evaporator.

2005 ◽  
Vol 127 (1) ◽  
pp. 85-94 ◽  
Author(s):  
Veerendra Mulay ◽  
Amit Kulkarni ◽  
Dereje Agonafer ◽  
Roger Schmidt

The combination of increased power dissipation and increased packaging density has led to substantial increases in chip and module heat flux in high-end computers. The challenge has been to limit the rise in chip temperature. In the past, virtually all commercial computers were designed to operate at temperatures above the ambient. However, researchers have identified the advantages of operating electronics at low temperatures. The primary purpose of low-temperature cooling using a vapor compression system are faster switching times of semiconductor devices, increased circuit speed due to lower electrical resistance of interconnecting materials, and a reduction in thermally induced failures of devices and components. Achievable performance improvements range from 1% to 3% for every 10°C lower transistor temperature, depending on the doping characteristics of the chip. The current research focuses on IBM’s mainframe, which uses a conventional refrigeration system to maintain chip temperatures below that of comparable air-cooled systems, but well above cryogenic temperatures. Although performance has been the key driver in the use of this technology, the second major reason for designing a system with low-temperature cooling is the improvement achieved in reliability to counteract detrimental effects, which rise as technology is pushed to the extremes. A mathematical model is developed to determine the time constant for an expansion valve sensor bulb. This time constant varies with variation in the thermophysical properties of the sensor element; that is, bulb size and bulb liquid. An experimental bench is built to study the effect of variation of evaporator outlet superheat on system performance. The heat load is varied from no load to full load (1 KW) to find out the system response at various loads. Experimental investigation is also done to see how the changes in thermophysical properties of the liquid in the sensor bulb of the expansion valve affect the overall system performance. Different types of thermostatic expansion valves are tested to investigate that bulb size, bulb constant, and bulb location have significant effects on the behavior of the system. Thermal resistance between the bulb and evaporator return line can considerably affect the system stability, and by increasing the thermal resistance, the stability can be further increased.


2013 ◽  
Vol 385-386 ◽  
pp. 233-236
Author(s):  
Qing Jiang Liu ◽  
Zeng Zhi Yuan ◽  
Jin Ting Sun ◽  
Fang Han

In order to improve refrigeration system stability and efficiency of the low pressure difference between thermostatic expansion valve, it is researched that the refrigeration system is the refrigerate capacity of the HSN7471-75 compressors. The system performance is analyzed and compared in the case of with and without refrigerant pumps. The results indicate that the COP of the refrigeration system with a pump can increase 31%. The reliability of system is also improved.


Author(s):  
Veerendra Mulay ◽  
Dereje Agonafer ◽  
Roger Schmidt

The combination of increased power dissipation and increased packaging density has led to substantial increases in chip and module heat flux in high-end computers. The challenge has been to limit the rise in chip temperature. In the past virtually all-commercial computers were designed to operate at temperatures above the ambient. However researchers have identified the advantages of operating electronics at low temperatures. The primary purpose of low temperature cooling using vapor compression system are faster switching times of semiconductor devices, increased circuit speed due to lower electrical resistance of interconnecting materials, and a reduction in thermally induced failures of devices and components. Achievable performance improvements range from 1 to 3% for every 10°C lower transistor temperature, depending on the doping characteristics of the chip. The current research focuses on IBM’s mainframe, which uses a conventional refrigeration system to maintain chip temperatures below that of comparable air-cooled systems, but well above cryogenic temperatures. Although performance has been the key driver in the use of this technology, the second major reason for designing a system with low temperature cooling is the improvement achieved in reliability to counteract detrimental effects, which rise as technology is pushed to the extremes. A mathematical model is developed to determine the time constant for expansion valve sensor blub. This time constant varies with variation in thermo-physical properties of sensor element that is bulb size and blub liquid. An experimental bench is built to study the effect of variation of evaporator outlet superheat on system performance. The heat load is varied from no load to full load (1KW) to find out the system response at various loads. Experimental investigation is also done to see how the changes in thermo-physical properties of the liquid in sensor bulb of expansion valve affect the overall system performance. Different types of thermostatic expansion valves are tested to investigate that bulb size; bulb constant and bulb location have significant effect on the behavior of the system. Thermal resistance between the bulb and evaporator return line can considerably affect the system stability and by increasing the thermal resistance, the stability can be further increased.


2018 ◽  
Vol 12 (2) ◽  
pp. 98 ◽  
Author(s):  
Jalaluddin . ◽  
Baharuddin Mire

Actual performance of photovoltaic module with solar tracking is presented. Solar radiation can be converted into electrical energy using photovoltaic (PV) modules. Performance of polycristalline silicon PV modules with and without solar tracking are investigated experimentally. The PV module with dimension 698 x 518 x 25 mm has maximum power and voltage is 45 Watt and 18 Volt respectively. Based on the experiment data, it is concluded that the performance of PV module with solar tracking increases in the morning and afternoon compared with that of fixed PV module. It increases about 18 % in the morning from 10:00 to 12:00 and in the afternoon from 13:30 to 14:00 (local time). This study also shows the daily performance characteristic of the two PV modules. Using PV module with solar tracking provides a better performance than fixed PV module. 


Author(s):  
Yasuhiro Matsumoto ◽  
Marco A. Ramos ◽  
Jose A. Urbano ◽  
Miguel A. Luna ◽  
Nun Pitalua-Diaz ◽  
...  

2014 ◽  
Vol 694 ◽  
pp. 163-168
Author(s):  
Liang Guo ◽  
Yun Liang ◽  
Xu Zhang ◽  
Xiao Tian Yang

With the rapid development of world economy, the energy crisis has become one of the urgent problems to be solved. Photovoltaic technology is a green new energy industry, no pollution is widely used all over the world. Typically, for photovoltaic component installation, only considering the utilization of components support cost and area, and the arrangement of components have not given enough attention. Photovoltaic module in use process will inevitably encounter the shadow, the shadow changes to make appropriate adjustments to the PV module arrangement can enhance the power generation capacity. Effect of the shadow on the photovoltaic system performance can be effectively used for photovoltaic component to bring help, is of positive significance. This study analyzed the villa model typical, and the rectangular shadow is modeling, in order to analyze the influence on the photovoltaic component. Through the conclusion of this study can determine the horizontal and vertical components of photovoltaic components which caused little damage, and provide a reference for future research of shadow and photovoltaic system performance.


2014 ◽  
Vol 556-562 ◽  
pp. 907-911
Author(s):  
Chang Wei He ◽  
Meng Zhang ◽  
Xiao Ping Jia ◽  
Yuan Liu

In the paper, the design scheme of the new cold store is proposed firstly, with the consideration of the latest technology application and the convenience and maneuverability of practical teaching. Then the refrigeration system is designed based on the calculation of the heat load of the cold store. The suited components such as compressor, evaporator, condenser and expansion valve are selected and the electrical system is designed. After that the whole unit is installed and adjusted to make sure that the installation is propitious to improve the system performance and convenient for training. Finally the thermal performance of the new cold store system is tested and compared with the old system test. The result shows that the matching of the new refrigeration system is reasonable and the new cold store is up to the mustard. With the help of training on the cold store, the students will meet the essential requirements of STCW 78/95 convention on application and management of the marine cold store.


Author(s):  
Kamil Jadu Ali ◽  
Ahmed Hasan Mohammad ◽  
Ghanim Thiab Hasan

<p><span>In this paper, the effect of the ambient temperature on the PV modules for different angles of inclinations and different intensities of the solar radiation on the surface of the PV module is considered by using empirical correlations for natural convection. An analytical model based on the energy balance equilibrium between the PV module and the environment conditions has been used. Also an expression for calculating the electric power of silicon PV modules in a function of the ambient temperature, the intensity of the solar radiation, the incident angle of the solar radiation to the surface of the PV module and the efficiency of the PV modules at STC conditions have been used. By comparing the obtained both results, it can be seen that the largest deviation between the power values obtained by the analytical model and expression is about (5 %). The results obtained indicates that in the case of a small number of PV modules corresponding to the required number for an average household, it is more economical to invest additional resources in increasing the PV module's surface area than in case of the PV module with sun tracking system. </span></p>