Investigation of Different Membrane Porosities on the Permeate Flux of Direct Contact Membrane Distillation

2021 ◽  
Vol 889 ◽  
pp. 85-90
Author(s):  
Asmaa Elrasheedy ◽  
Mohammed Rabie ◽  
Ahmed Hassan El-Shazly ◽  
Mohamed Bassyouni ◽  
Ahmed Abd El-Moneim ◽  
...  

In the present study the surface morphology of electrospun fibers at different polystyrene (PS) solution concentration was studied by SEM imaging to determine the best PS solution concentration yielding continuous uniform beadles fibers. Contact angle measurements of the optimum fabricatedPS-18 membrane confirmed the super hydrophobic property of the membrane that exhibited a static water contact angle of 145o. Numerical investigation of the performance of PS-18 membrane at different membrane thicknesses and porosities on direct contact membrane distillation showed that increasing the membrane porosity increases the permeate flux considerably.

Desalination by the direct contact membrane distillation (DCMD) for prepared saline water and Ambazari lake water sample was investigated. The self-prepared ultrasound assisted polyvinylidene fluoride (PVDF) membrane by wet phase inversion method exhibited effects on membrane contact angle, pore size, and porosity and investigated performance of DCMD. Membrane properties are characterized and employed in theoretical model with assumptions for water vapor transport in the transition region. It is observed that similar pattern obtained for permeate flux from experimental results and simulated results for transition region. Effects of operating parameter on permeate flux also simulated and compared with experimental data. For this work mathematical models developed and simulated in Polymath. PVDF membrane exhibited its characteristics like contact angle, pore size and flux enhancement may be due to ultrasound assisted polymer solution preparation for membrane casting.


Polymers ◽  
2021 ◽  
Vol 13 (1) ◽  
pp. 160
Author(s):  
Asmaa Elrasheedy ◽  
Mohammed Rabie ◽  
Ahmed El-Shazly ◽  
Mohamed Bassyouni ◽  
S.M.S. Abdel-Hamid ◽  
...  

The effect of compositing multiwalled carbon nanotubes (MWCNTs) with polystyrene (PS) to fabricate nanofibrous membrane by electrospinning technique and comparing the direct contact membrane distillation (DCMD) performance of the blank and composite membranes is evaluated numerically. Surface morphology of both the pristine and the composite membrane was studied by SEM imaging while the average fiber diameter and average pore size were measured using ImageJ software. Static water contact angle and porosities were also determined for both membranes. Results showed significant enhancement in both the hydrophobicity and porosity of the composite membrane by increasing the static water contact angle from 145.4° for the pristine PS membrane to 155° for the PS/MWCNTs composite membrane while the porosity was increased by 28%. Simulation results showed that at any given feed inlet temperature, the PS/MWCNTs membrane have higher permeate flux and better overall system performance.


Membranes ◽  
2021 ◽  
Vol 11 (7) ◽  
pp. 493
Author(s):  
Amine Charfi ◽  
Fida Tibi ◽  
Jeonghwan Kim ◽  
Jin Hur ◽  
Jinwoo Cho

This study aims to investigate the effect of operational conditions on organic fouling occurring in a direct contact membrane distillation (DCMD) system used to treat wastewater. A mixed solution of sodium alginate (SA) and bovine serum albumin (BSA) was used as a feed solution to simulate polysaccharides and proteins, respectively, assumed as the main organic foulants. The permeate flux was observed at two feed temperatures 35 and 50 °C, as well as three feed solution pH 4, 6, and 8. Higher permeate flux was observed for higher feed temperature, which allows higher vapor pressure. At higher pH, a smaller particle size was detected with lower permeate flux. A mathematical model based on mass balance was developed to simulate permeate flux with time by assuming (i) the cake formation controlled by attachment and detachment of foulant materials and (ii) the increase in specific cake resistance, the function of the cake porosity, as the main mechanisms controlling membrane fouling to investigate the fouling mechanism responsible of permeate flux decline. The model fitted well with the experimental data with R2 superior to 0.9. High specific cake resistance fostered by small particle size would be responsible for the low permeate flux observed at pH 8.


2018 ◽  
Vol 30 (1) ◽  
pp. 109-120 ◽  
Author(s):  
Dong-Wan Cho ◽  
Gihoon Kwon ◽  
Jeongmin Han ◽  
Hocheol Song

In this study, the influence of humic acid on the treatment of coalbed methane water by direct contact membrane distillation was examined with bench-scale test unit. During short-term distillation (1000 min), high level of humic acid above 50 ppm resulted in significant decrease in permeate flux, while low level of humic acid (∼2 ppm) had little influence on the flux. For the long-term distillation (5000 min), the flux decline began at 3400 min in the presence of 5 ppm humic acid and 5 mM Ca2+, and decreased to ∼40% of initial flux at 5000 min. The spectroscopic analysis of the membrane used revealed that the surface was covered by hydrophilic layers mainly composed of calcite. The membrane fouling effect of humic acid became more significant in the presence of Ca2+ due to more facile calcite formation on the membrane surface. It was demonstrated that humic acid enhanced CaCO3 deposition on the membrane surfaces, thereby expediting the scaling phenomenon.


2021 ◽  
Vol 2021 ◽  
pp. 1-15
Author(s):  
Guangfu Cao ◽  
Qingfen Ma ◽  
Jingru Li ◽  
Shenghui Wang ◽  
Chengpeng Wang ◽  
...  

A Bubbling and Vacuum-enhanced direct contact membrane distillation (BVDCMD) is proposed to improve the water production rate of the direct contact membrane distillation (DCMD-)based seawater desalination process. Its heat and mass transfer mechanism are theoretically analyzed, and a CFD model is established, which is verified by the published data. Four types of the noncondensable gas, “O2,” “air,” “N2,” and “H2,” are adopted as the bubbling gas, and their process enhancements under different pressure of permeate side, temperature, and NaCl concentration of feed side and flow velocities are investigated. The results show that the permeate flux increased remarkably with the decrease in the viscosity of the bubbling gas, and hence, “H2” is the best option for the bubbling gas, with the permeate flux being enhanced by 144.11% and the effective heat consumption being increased by 20.81% on average. The effective water production rate of BVDCMD is predicted to be 42.38% more than that of DCMD, proving its feasibility in the seawater desalination.


2014 ◽  
Vol 69 (9) ◽  
Author(s):  
S. O. Lai ◽  
K. C. Chong ◽  
K. M. Lee ◽  
W. J. Lau ◽  
B. S. Ooi

Membrane distillation (MD) is one of the recent rising membrane separation techniques adopted in the desalination and wastewater treatment. Unlike other pressure-driven separation processes such as reverse osmosis and nanofiltration, MD is a thermal-driven process which involves vapor pressure difference across the feed and permeates solutions. As such, MD requires low energy consumption. Hydrophobic polymeric materials such as polyvinylidene fluoride (PVDF) are frequently used in direct contact membrane distillation (DCMD) due to low surface energy and promising thermal resistance. In this study, the DCMD hollow fiber membranes were separately prepared with PVDF and PVDF blended with lithium chloride (LiCl) through dry/wet phase inversion method. Subsequently, the membranes were used in a DCMD process to remove sodium chloride (NaCl) under different feed inlet temperatures to examine the effect of LiCl additives on the neat membrane. The result showed that by adding LiCl into the neat membrane solution, the finger-like structure was change to a sponge-like structure with microvoids. Furthermore, the performance of the LiCl additive membrane in term of permeate flux was found to be 20% higher compared to that of the neat membrane. Other results of the membrane characteristics were also discussed.      


2010 ◽  
Vol 62 (2) ◽  
pp. 347-352 ◽  
Author(s):  
Ching-Jung Chuang ◽  
Kuo-Lun Tung ◽  
Yang-Hsiang Fan ◽  
Chii-Dong Ho ◽  
James Huang

This paper reports experiments using a flat-sheet module with 0.18 ∼ 0.45 μm ePTFE (expanded polytetrafluoroethylene) and PVDF (polyvinylidene fluoride) membranes to show the effects of membrane properties, salt concentration and fluid hydrodynamics on the permeate flux and salt rejection of DCMD (direct contact membrane distillation). A theoretical prediction of the permeate flux was carried out, and was in close agreement with the experimental results. In addition, the energy integration of the process was also analyzed in order to evaluate module design to increase energy efficiency. According to the simulated results of the energy integration design, a combination of simultaneous cooling of the permeate stream and an additional heat exchanger to lower the temperature of the permeate stream not only enhances the MD flux, but also reduces energy consumption.


2010 ◽  
Vol 61 (12) ◽  
pp. 3178-3187 ◽  
Author(s):  
D. Y. Hou ◽  
J. Wang ◽  
B. Q. Wang ◽  
Z. K. Luan ◽  
X. C. Sun ◽  
...  

The direct contact membrane distillation (DCMD) applied for fluoride removal from brackish groundwater is presented. The self-prepared polyvinylidene fluoride membrane exhibited high rejection of inorganic salt solutes and a maximum permeate flux 35.6 kgm−2 h−1 was obtained. The feed concentration had no marked impact on the permeate flux and the rejection of fluoride. The precipitation of CaCO3 would clog the hollow fiber inlets and foul the membrane surface with the increase of concentration factor when natural groundwater was used directly as the feed, which resulted in a rapid decline of the module efficiency. This phenomenon was diminished by acidification of the feed. The experimental results showed that the permeate flux and the quality of obtained distillate kept stable before concentration factor reached 5.0 with the acidified groundwater as feed. The membrane module efficiency began to decline gradually when the feed continued to be concentrated, which can be mainly attributed to the formation of CaF2 deposits on the membrane surface. Finally, a 300 h continuous fluoride removal experiment on acidified groundwater was carried out with concentration factor at 4.0, the permeate flux kept stable and the permeate fluoride was not detected.


2017 ◽  
Vol 100 ◽  
pp. 258-267 ◽  
Author(s):  
Isam Janajreh ◽  
Khadije El Kadi ◽  
Noora Al Hammadie ◽  
Raed Hashaikeh

Sign in / Sign up

Export Citation Format

Share Document