scholarly journals Electroanalytical Characterisation of Dopa Decarboxylase Inhibitors Carbidopa and Benserazide on Multiwalled Carbon Nanotube and Poly(Nile blue A) Modified Glassy Carbon Electrodes

2011 ◽  
Vol 2011 ◽  
pp. 1-7 ◽  
Author(s):  
Dilek Kul ◽  
Christopher M. A. Brett

Modified glassy carbon electrodes have been made by deposition of functionalised multiwalled carbon nanotubes (MWCNTs) followed by formation of poly(Nile blue) (PNB) films by electropolymerisation, using potential cycling in 0.1 M phosphate buffer solution (PBS) at pH 6.0. The electrochemical oxidation of carbidopa (CD) and benserazide (BS) on these MWCNTs/PNB-modified electrodes was investigated using cyclic and differential pulse voltammetry in 0.1 M PBS at different values of pH between 5.0 and 8.0; both CD and BS gave one diffusion-controlled irreversible oxidation peak in cyclic voltammetry. Analytical characterisation of CD and BS was carried out in 0.1 M PBS, pH 5.0. Peak currents in differential pulse voltammetry were linear over the concentration range of1×10−5to1×10−4 M for CD and4×10−6to4×10−5 M for BS. The repeatability, precision, and accuracy of the method were also investigated. Higher sensitivities and lower detection limits, of 1.17 μM for CD and 0.50 μM for BS, were obtained with this new modified electrode compared with previous studies reported in the literature.

2021 ◽  
Author(s):  
Yan Jin ◽  
Tong QI ◽  
Yuqing Ge ◽  
Jin Chen ◽  
Li juan Liang ◽  
...  

In this paper, ultrasensitive electrochemical determination of phosphate in water is achieved by hydrophilic TiO2 modified glassy carbon electrodes for the first time. Differential pulse voltammetry (DPV) method is proposed...


1987 ◽  
Vol 65 (5) ◽  
pp. 1133-1138 ◽  
Author(s):  
Robert D. Guy ◽  
Sarath Namaratne

The properties of mercury-coated glassy carbon electrodes coated with a thin membrane of Nation 117 were studied to evaluate the potential analytical applications in metal ion analysis. The Nation membrane was found to contain two types of binding sites — a strong site that bound metal ions in a nonelectroactive form and cation exchange sites that were useful for preconcentrations prior to differential pulse voltammetry. The exchange constants for the weak sites ranged from 0.413 for copper to 12.5 for methyl viologen. The differential pulse currents were increased by a factor of 75 to 100 and a linear calibration curve was observed from about 25 n M to 1000 n M for copper, lead, cadmium, and zinc. The ion exchange reaction is very sensitive to ionic strength and significant enrichments occur only in solutions of ionic strength below 0.10. The Nafion-coated glassy carbon electrode in a flow cell can be used to determine the free copper ion concentration in samples by a combination of ion exchange and differential pulse voltammetry. The flow-through system required about 15 mL of sample solution and an analysis time of about 10 min. The ion exchange measurement gave a linear calibration from 40 n M to 10 μ M for free copper.


Author(s):  
Fatma Ağin ◽  
Gökçe Öztürk ◽  
Dilek Kul

Objective: The electrochemical analysis of ephedrine which is a sympathometric drug has been studied using poly(Nile blue A) modified glassy carbon electrodes using cyclic voltammetry, differential pulse voltammetry and square wave voltammetry. Methods: The modified electrodes were prepared by potential cycling electropolymerization of Nile blue A in 0.1 M phosphate buffer solution at pH 6.0. The redox behavior of ephedrine was investigated in different buffer solutions at pH values between 5.5 and 9.0. Results: Scan rate studies showed that the electron transfer reaction of ephedrine was diffusion controlled. A linear response was obtained between the peak current and the ephedrine concentration in the range of 0.6 to 100 μM with a limit of detection of 2.91×10-3 µM for differential pulse voltammetry in Britton-Robinson buffer solution at pH 9.0. The linearity range of ephedrine in human urine was between 1.0 and 100 μM with a detection limit of 8.16 nM. Conclusion: The recovery studies in both pharmaceutical dosage forms and urine showed that the proposed method ensured good selectivity, precision and accuracy without any interference from inactive excipients.


2011 ◽  
Vol 306-307 ◽  
pp. 1221-1224
Author(s):  
Dan Zi Sun

Carbon-nanotube(CNT)-modified glassy carbon electrodes exhibiting strong electrocatalytic response toward nitrite are described. Cyclic voltammetry and differential pulse voltammetry are used to investigate the electrocatalytic property of CNT-modified glassy carbon electrode toward the reduction of nitrite. The modified electrode could be used for nitrite sensing.


Sign in / Sign up

Export Citation Format

Share Document