Determination of LTCC Shrinkage Variations from Tape Manufacturer to Consumer

2014 ◽  
Vol 2014 (1) ◽  
pp. 000668-000672 ◽  
Author(s):  
James Kupferschmidt ◽  
Michael Girardi ◽  
Brent Duncan ◽  
Daren Whitlock

Low Temperature Cofired Ceramic (LTCC) technology can be applied in numerous functions due to a wide variety of benefits, particularly related to flexibility of applications. Controlling the LTCC shrinkage tolerances in the x, y, and z dimensions is critical during manufacturing and avoids an assortment of down-stream issues that will affect yields. All manufacturers of LTCC tape provide a Certificate of Analysis (COA), which contains the results of the manufacturer's shrinkage testing so production variation can be established from lot to lot. Data from this COA is generally used as a starting point in the shrinkage predictions for manufacturing purposes; however, verification of this data must be performed prior to initiating an LTCC build. This paper investigates validation of one manufacturer's COA data and explains how shrinkage differences can occur between the COA data and the data collected during the verification process. The tracking of this data is also presented as a means to ensure proper controls are in place, and the type and style of lamination and cofiring are shown to be significant contributors to these differences. Data will then be presented in association with characterization prior to and after relocation of LTCC fabrication equipment. Additionally, the COA data can be incorporated into shrinkage estimates that will be utilized to set up process parameters, tolerances, and a control plan.

2013 ◽  
Vol 2013 ◽  
pp. 1-8 ◽  
Author(s):  
L. D. Abdulaeva ◽  
O. I. Silyukov ◽  
Yu. V. Petrov ◽  
I. A. Zvereva

In the present work protonic forms of layeredn=1,3Ruddlesden-Popper oxides HLnTiO4and H2Ln2Ti3O10(Ln = La, Nd) were used as the starting point for soft chemistry synthesis of two series of perovskite-like compounds by acid leaching and exfoliation, promoted by vanadyl sulfate. The last route leads to the nanostructured VO2+containing samples. Characterization by SEM, powder XRD, and TGA has been performed for the determination of the structure and composition of synthesized oxides.


1996 ◽  
Vol 33 (1) ◽  
pp. 311-323 ◽  
Author(s):  
A. Witteborg ◽  
A. van der Last ◽  
R. Hamming ◽  
I. Hemmers

A method is presented for determining influent readily biodegradable substrate concentration (SS). The method is based on three different respiration rates, which can be measured with a continuous respiration meter which is operated in a cyclic way. Within the respiration meter nitrification is inhibited through the addition of ATU. Simulations were used to develop the respirometry set-up and decide upon the experimental design. The method was tested as part of a large measurement programme executed at a full-scale plant. The proposed respirometry set-up has been shown to be suitable for a semi-on-line determination of an influent SS which is fully based on the IAWQ #1 vision of the activated sludge process. The YH and the KS play a major role in the principle, and should be measured directly from the process.


2019 ◽  
Vol 22 (5) ◽  
pp. 346-354
Author(s):  
Yan A. Ivanenkov ◽  
Renat S. Yamidanov ◽  
Ilya A. Osterman ◽  
Petr V. Sergiev ◽  
Vladimir A. Aladinskiy ◽  
...  

Aim and Objective: Antibiotic resistance is a serious constraint to the development of new effective antibacterials. Therefore, the discovery of the new antibacterials remains one of the main challenges in modern medicinal chemistry. This study was undertaken to identify novel molecules with antibacterial activity. Materials and Methods: Using our unique double-reporter system, in-house large-scale HTS campaign was conducted for the identification of antibacterial potency of small-molecule compounds. The construction allows us to visually assess the underlying mechanism of action. After the initial HTS and rescreen procedure, luciferase assay, C14-test, determination of MIC value and PrestoBlue test were carried out. Results: HTS rounds and rescreen campaign have revealed the antibacterial activity of a series of Nsubstituted triazolo-azetidines and their isosteric derivatives that has not been reported previously. Primary hit-molecule demonstrated a MIC value of 12.5 µg/mL against E. coli Δ tolC with signs of translation blockage and no SOS-response. Translation inhibition (26%, luciferase assay) was achieved at high concentrations up to 160 µg/mL, while no activity was found using C14-test. The compound did not demonstrate cytotoxicity in the PrestoBlue assay against a panel of eukaryotic cells. Within a series of direct structural analogues bearing the same or bioisosteric scaffold, compound 2 was found to have an improved antibacterial potency (MIC=6.25 µg/mL) close to Erythromycin (MIC=2.5-5 µg/mL) against the same strain. In contrast to the parent hit, this compound was more active and selective, and provided a robust IP position. Conclusion: N-substituted triazolo-azetidine scaffold may be used as a versatile starting point for the development of novel active and selective antibacterial compounds.


1989 ◽  
Vol 54 (7) ◽  
pp. 1785-1794 ◽  
Author(s):  
Vlastimil Kubáň ◽  
Josef Komárek ◽  
Zbyněk Zdráhal

A FIA-FAAS apparatus containing a six-channel sorption equipment with five 3 x 26 mm microcolumns packed with Spheron Oxin 1 000, Ostsorb Oxin and Ostsorb DTTA was set up. Combined with sorption from 0.002M acetate buffer at pH 4.2 and desorption with 2M-HCl, copper can be determined at concentrations up to 100, 150 and 200 μg l-1, respectively. For sample and eluent flow rates of 5.0 and 4.0 ml min-1, respectively, and a sample injection time of 5 min, the limit of copper determination is LQ = 0.3 μg l-1, repeatability sr is better than 2% and recovery is R = 100 ± 2%. The enrichment factor is on the order of 102 and is a linear function of time (volume) of sample injection up to 5 min and of the sample injection flow rate up to 11 ml min-1 for Spheron Oxin 1 000 and Ostsorb DTTA. For times of sorption of 60 and 300 s, the sampling frequency is 70 and 35 samples/h, respectively. The parameters of the FIA-FAAS determination (acetylene-air flame) are comparable to or better than those achieved by ETA AAS. The method was applied to the determination of traces of copper in high-purity water.


1996 ◽  
Vol 61 (6) ◽  
pp. 844-855 ◽  
Author(s):  
Olga Šolcová ◽  
Petr Schneider

It was shown that the sampling loop, detector and connecting elements in the chromatographic set-up for determination of transport parameters by the dynamic method significantly influence the response peaks from columns packed with porous or nonporous particles. A method, based on the use of convolution theorem, was developed which can take these effects into account. The applicability of this method was demonstrated on the case of axial dispersion in a single-pellet-string column (SPSR) packed with nonporous particles. It is possible to handle also responses from columns packed with porous particles by a similar procedure.


Sign in / Sign up

Export Citation Format

Share Document