scholarly journals Co-Precipitation Procedure Using Copper (II) Methylbutyldithiocarbamate for Atomic Absorption Spectrophotometric Determination of Heavy Metals in Aqueous Standard Solutions and Environmental Samples

Author(s):  
Ayodele Rotimi Ipeaiyeda
2012 ◽  
Vol 66 (1) ◽  
pp. 105-112 ◽  
Author(s):  
Ayodele Rotimi Ipeaiyeda ◽  
Adekunle Johnson Odola

A co-precipitation technique for nickel(II), chromium(II), manganese(II), lead(II) and zinc(II) with the aid of copper(II) cyclo-hexylmethyldithiocarbamate was established. The influences of some analytical parameters such as pH, sample volume, amounts of cyclo-hexylmethyldithiocarbamate and copper(II) on the recovery of metal ions were investigated. The heavy metals in the precipitate were determined by flame atomic absorption spectrophotometry. The range of detection limits for the heavy metals was 0.003–0.005 mg/L. The atomic spectrometric technique with co-precipitation procedure was successfully applied for the determination of Ni, Cr, Mn, Pb and Zn in industrial wastewater and sediment samples from Ladipo stream in Lagos, Nigeria. The mean concentrations for these metals using co-precipitation procedure were not significantly different from corresponding concentrations obtained using spectrometric techniques without co-precipitation procedure.


2016 ◽  
Vol 99 (1) ◽  
pp. 273-278 ◽  
Author(s):  
Mustafa Soylak ◽  
Ayse Aydin ◽  
Nebiye Kizil

Abstract A preconcentration/separation system for cadmium(II), nickel(II), copper(II), lead(II), iron(II), cobalt(II), and manganese(II) ions has been established prior to their atomic absorption spectrometric determinations. The procedure is based on the co-precipitation of these ions by the aid of a praseodymium hydroxide (Pr(OH)3) precipitate. The precipitate was dissolved in 0.5 mL of concentrated HNO3, and made up to 10.0 mL with water. The analytes were determined by a flame atomic absorption spectrometer. The effects of analytical parameters including pH, amounts of praseodymium as carrier element, sample volume, etc. on the recoveries of heavy metals were investigated. The effects of matrix ions were also examined. The limits of detection for analyte ions were found in the range between 0.7–5.2 μg/L. The validation of this present procedure was verified by the analysis of certified reference materials, TMDA-54.4 (fortified water) and NIST 1570a (spinach leaves). The proposed co-precipitation procedure was applied for the determination of cadmium(II), nickel(II), copper(II), lead(II), iron(II), cobalt(II), and manganese(II) ions in various environmental water samples.


1979 ◽  
Vol 62 (1) ◽  
pp. 153-159
Author(s):  
Luis F Corominas ◽  
Victor M Boy ◽  
Manuel Guijosa

Abstract The official first action AOAC method for the spectrophotometric determination of biuret in urea, 2.072—2.074, was compared with official first action AOAC method 2.C01-2.C03 (atomic absorption spectrophotometry), 2 simplified versions of 2.072-2.074, and modified versions of 2 alternative procedures of the International Organization for Standardization. Three synthetic urea samples (0.3, 1.4, and 3.0% biuret) and 1 commercial urea sample (1.0% biuret) were analyzed. The methods proved to be equivalent and none showed a definite advantage over 2.072-2.074. The purification of biuret and the interference by ammonia are also discussed.