scholarly journals 3D Multi-architectural Tissue Engineering Scaffolds: Degradation and Cell Culture Study

2012 ◽  
Vol 01 (04) ◽  
Author(s):  
Ruszymah Idrus
2017 ◽  
Vol 28 (15) ◽  
pp. 1617-1638 ◽  
Author(s):  
Zhale Atoufi ◽  
Payam Zarrintaj ◽  
Ghodratollah Hashemi Motlagh ◽  
Anahita Amiri ◽  
Zohreh Bagher ◽  
...  

2011 ◽  
Vol 17 (21-22) ◽  
pp. 2583-2592 ◽  
Author(s):  
Jessica A. DeQuach ◽  
Shauna H. Yuan ◽  
Lawrence S.B. Goldstein ◽  
Karen L. Christman

2008 ◽  
Vol 9 (5) ◽  
pp. 527-532 ◽  
Author(s):  
B. Shannon Danes ◽  
Margaret E. Hodson ◽  
J. Batten

2015 ◽  
Vol 6 (4) ◽  
pp. 1054-1063 ◽  
Author(s):  
Alexander Röder ◽  
Elena García-Gareta ◽  
Christina Theodoropoulos ◽  
Nikola Ristovski ◽  
Keith Blackwood ◽  
...  

e-Polymers ◽  
2007 ◽  
Vol 7 (1) ◽  
Author(s):  
Malgorzata Lewandowska-Szumieł ◽  
Janusz Kozakiewicz ◽  
Piotr Mrówka ◽  
Agnieszka Jurkowska ◽  
Edyta Sienkiewicz-Łatka ◽  
...  

AbstractSilicone-urethanes, polymers combining the characteristics of two widely used biomaterials, i.e. polyurethanes and silicones, are highly valued in many applications, including medical implants. To assess properties of these materials in contact with living cells, a set of different silicone-urethane materials, candidates for tissue engineering scaffolds, was synthesized and characterized. Two different oligomeric siloxane diols: Tegomer-2111 (Teg) and KF-6001 (KF), and two different types of diisocyanate, MDI and IPDI, were used in synthesis. Blood platelets adhesion to surfaces of selected materials showed a higher thrombogenicity of material based on Teg. Human fibroblasts were used in in vitro biocompatibility tests. The viability of cells cultured on silicone-urethanes was tested by XTT assay. Teg-based silicone-urethanes showed a significantly higher biocompatibility than those based on KF. Materials based on MDI compared to IPDI were found to be significantly more favoured by cells, not necessarily due to the type of diisocyanate but maybe also because of the necessity of using potentially toxic catalyst which accompanies the use of IPDI. Our studies indicate that silicone-urethanes are potent materials for tissue engineering products development. On the basis of the observations performed in cell culture, Tegomer- 2111 as oligomeric siloxane diol and MDI as diisocyanate are recommended as starting materials for silicone-urethane scaffolds synthesis.


2012 ◽  
Vol 7 (1) ◽  
Author(s):  
Ahmet Baris Durukan ◽  
Beril Erdem ◽  
Elif Durukan ◽  
Handan Sevim ◽  
Tugce Karaduman ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document