scholarly journals Comparative Study of Linear and Non-Linear Controls of Three-Phase Shunt Active Filters for Improving the Quality of Electrical Energy

2019 ◽  
Vol 11 (03) ◽  
pp. 149-166 ◽  
Author(s):  
Mamane Adamou ◽  
Nabil Alkassoum ◽  
André Foulani ◽  
Amadou Seidou Maiga
Author(s):  
Mohamed Ali Moussa ◽  
Bachir Belmadani ◽  
Ahmed Wahid Belarbi ◽  
Rachid Taleb

<p>This document is a contribution to improve the quality of electrical energy in the distribution network.<br />In this article we will present a method that allows us to clean up in a very considerable way the electrical network of both harmonics and inter harmonics provoked, basically by the ultrafast switches used when controlling a PWM inverter supplying a three-phase asynchronous motor. We notice that this method can be generalized for other loads creating inter-harmonics.<br />This proposed method was simulated using the MATLAB/SIMULINK software and had given remarkable results (there is a considerable reduction in total harmonic distortion (THD) of source current from 29.52% to 0.82%)</p>


2019 ◽  
Vol 140 ◽  
pp. 04010 ◽  
Author(s):  
Egor Zamyatin ◽  
Irina Voytyuk ◽  
Elena Zamyatina

The cost of any product includes the cost of electrical energy in its production. Enterprises use various methods to reduce the cost of electric energy. One of the most common methods is to reduce the loss of active power in the distribution network of an enterprise. This is achieved by compensating for distortions in the power quality of electrical energy using compensating devices. The method presented in the article offers point compensation of distortions in the power quality indicators of electric energy. Point connection of compensating devices allows their small number to be used. But, at the same time, a greater effect is achieved. The connection points of compensating devices are determined by the developed method. The method includes three stages: collecting data on consumers of electric energy at an enterprise and on the topology of the distribution electric network, analyzing the results obtained using the developed algorithm, and determining connection points using the Pareto method. Also, the developed method was compared with the classical ones according to the criterion of the ratio of implementation costs to the effect of its application.


Author(s):  
Aleksandr V. Vinogradov ◽  
Aleksey V. Bukreyev ◽  
Alina V. Vinogradova ◽  
Vadim E. Bol’shev

Identifying sections of 0.4 kilovolt power grid lines with increased power losses is an urgent task, the solution of which will free up some of the funds spent by power grid companies to compensate for power losses and direct them to the reconstruction and modernization of electric networks. It is necessary to monitor electricity consumption on sections of power grid lines and on the connections of consumers, and compare data on consumption. Existing devices that analyze the quality of electrical energy and can control current and power in the network, such as power quality analyzers, do not have the full necessary qualities, since they are intended for other purposes, and they are also very expensive. (Research purpose) The research purpose is in developing technical means for identifying sections of 0.4 kilovolt power grid lines with increased power losses, which also allow performing a survey of operating modes of power grid lines. (Materials and methods) The article presents a review of literary sources and an analysis of statistical data. (Results and discussion) The article presents developed technical tools for inspection of power grid lines of 0.4 kilovolts and identification of areas with increased losses of electrical energy, portable single-phase and three-phase electric meter and timer. The single-phase mobile electric meter and timer can be used for the survey of single-phase connections of consumers, three-phase one can be used for the survey of any sections of power lines. Authors also developed a version of the portable electric meter and timer with up to six independent sensors. (Conclusions) It is most rational to use a version of the mobile meter and timer equipped with Wi-Fi data transmission technology to detect power losses on sections of 0.4 kilovolts power grid lines, since in this case simultaneous monitoring of several sections is provided with the possibility of obtaining information from sensors in real time. The data allow to calculate technological and commercial losses on power line sections and draw conclusions about whether they are overstated.


Author(s):  
Sergey Shevchenko ◽  
Dmytro Danylchenko ◽  
Dmytro Kuznetsov ◽  
Serhii Petrov

2021 ◽  
Vol 6 (2) ◽  
Author(s):  
Asmar Asmar ◽  
Wahri Sunanda

One of the performances of the electric power system can be seen from the quality of electrical energy. In this study, the measurement of the quality of electrical energy was carried out using a power quality meter to obtain the values of current, voltage, frequency, total current harmonic distortion and total voltage harmonic distortion in the building of the Faculty of Engineering, Universitas Bangka Belitung. From measurements on the 3 existing buildings, it was found that the measured voltage value range was still at  + 5% to - 10% of the 220 Volt secondary distribution voltage value and the frequency value was still in the range of 49.5 Hz to 50.5 Hz. The total value of voltage harmonic distortion is still below the required value, but the total value of current harmonic distortion is above the required value.


Sign in / Sign up

Export Citation Format

Share Document