scholarly journals Research on the Arrangement of Dew Point Temperature Detectors of Capillary Plane Radiation Air-Conditioning

2014 ◽  
Vol 02 (04) ◽  
pp. 76-81
Author(s):  
Xuelai Liu ◽  
Jie Wu
2020 ◽  
pp. 1420326X2096738
Author(s):  
Zan-She Wang ◽  
Fang-Ting Yin ◽  
Ran Li ◽  
Zhao-Lin Gu

The polyvinylidene fluoride hollow fibre membrane air dehumidification tests were carried out between the liquid desiccant solutions and the wet air. Three liquid desiccant solutions of LiBr solution (50%), LiCl solution (35%) and CaCl2 solution (40%) were tested under different wet air conditions. The results showed that all the membrane dehumidification processes were stable. The air moisture content in the outlet of the membrane was maintained as 6.5 g/kg (da)–8.2 g/kg (da) when the air moisture content in the inlet of the membrane was operated from 17.1 g/kg (da) to 32.4 g/kg (da). The dehumidification amount of LiBr solution (50%) and LiCl solution (35%) was more productive. On this basis, a membrane-based air pre-dehumidification process for the capillary radiant air conditioning system was built. Since the ideal dew point temperature range of the indoor air is below 14–17°C according to the cold supply water, all the air moisture content at the membrane outlet is much lower than that of the ideal dew point temperature range, which means non-condensing occurs in the capillary tube surface. The membrane-based air pre-dehumidification process can easily form an adaptive regulation process of humidity with the capillary radiant air conditioning system under different environmental parameters.


Author(s):  
Wei Bing ◽  
Li Li ◽  
Jiang Lu ◽  
Zhang Wei

At present all cold air distribution systems are being used widely due to their advantages of smaller ductwork, shorter floor-to-floor height and less energy consumption etc. They are mostly used in VAV (Variable Air Volume) systems or with the radiant panel systems in the office and residential buildings at the supply air dew point temperature of 6∼10°C, rarely used in large space buildings. The technology of stratified air conditioning is one of the energy saving technologies to large space buildings, which has been popularly used in the conventional air supply systems with the supply air dew point temperature of 11∼16°C. In this paper, the cold air distribution system and the stratified air conditioning technology in a large space building are combined to study. With the method of CFD, the indoor thermal environment of a large space workshop is simulated. The velocity and the temperature as well as the relative humidity fields under different air flow modes are presented, analyzed and compared. With the help of numerical simulation results, the optimal airflow mode is proposed, which show that the all cold air distribution with the stratified air conditioning is a good option for large space buildings. All these above will be good references to the application of cold air distribution system and the selection of the airflow mode in large space buildings.


2021 ◽  
Vol 338 ◽  
pp. 01027
Author(s):  
Jan Taler ◽  
Bartosz Jagieła ◽  
Magdalena Jaremkiewicz

Cooling towers, or so-called evaporation towers, use the natural effect of water evaporation to dissipate heat in industrial and comfort installations. Water, until it changes its state of aggregation, from liquid to gas, consumes energy (2.257 kJ/kg). By consuming this energy, it lowers the air temperature to the wet-bulb temperature, thanks to which the medium can be cooled below the ambient temperature. Evaporative solutions are characterized by continuous water evaporation (approx. 1.5% of the total water flow) and low electricity consumption (high EER). Evaporative (adiabatic) cooling also has a positive effect on the reduction of electricity consumption of cooled machines. Lowering the relative humidity (RH) by approx. 2% lowers the wet-bulb temperature by approx. 0.5°C, which increases the efficiency of the tower, operating in an open circuit, expressed in kW, by approx. 5%, while reducing water consumption and treatment costs. The use of the M-Cycle (Maisotsenko cycle) to lower the temperature of the wet thermometer to the dew point temperature will reduce operating costs and increase the efficiency of cooled machines.


Water ◽  
2019 ◽  
Vol 11 (3) ◽  
pp. 582 ◽  
Author(s):  
Sultan Noman Qasem ◽  
Saeed Samadianfard ◽  
Hamed Sadri Nahand ◽  
Amir Mosavi ◽  
Shahaboddin Shamshirband ◽  
...  

In the current study, the ability of three data-driven methods of Gene Expression Programming (GEP), M5 model tree (M5), and Support Vector Regression (SVR) were investigated in order to model and estimate the dew point temperature (DPT) at Tabriz station, Iran. For this purpose, meteorological parameters of daily average temperature (T), relative humidity (RH), actual vapor pressure (Vp), wind speed (W), and sunshine hours (S) were obtained from the meteorological organization of East Azerbaijan province, Iran for the period 1998 to 2016. Following this, the methods mentioned above were examined by defining 15 different input combinations of meteorological parameters. Additionally, root mean square error (RMSE) and the coefficient of determination (R2) were implemented to analyze the accuracy of the proposed methods. The results showed that the GEP-10 method, using three input parameters of T, RH, and S, with RMSE of 0.96°, the SVR-5, using two input parameters of T and RH, with RMSE of 0.44, and M5-15, using five input parameters of T, RH, Vp, W, and S with RMSE of 0.37 present better performance in the estimation of the DPT. As a conclusion, the M5-15 is recommended as the most precise model in the estimation of DPT in comparison with other considered models. As a conclusion, the obtained results proved the high capability of proposed M5 models in DPT estimation.


Sign in / Sign up

Export Citation Format

Share Document