scholarly journals Limited Sensitivity of a Rapid SARS-CoV-2 Antigen Detection Assay for Surveillance of Asymptomatic Individuals in Thailand

Author(s):  
Anek Mungomklang ◽  
Nichapa Trichaisri ◽  
Jittima Jirachewee ◽  
Jaravee Sukprasert ◽  
Warut Tulalamba ◽  
...  

COVID-19 is an infectious disease caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and is a global pandemic. Therefore, rapid and accurate tests for SARS-CoV-2 screening are urgently needed to expedite disease prevention and control especially in community transmission. Since late December 2020, Thailand has faced a new wave of COVID-19 outbreaks. The Thai National Disease Control program at the Ministry of Public Health has identified suitable measure for mass screening. A SARS-CoV-2 antigen-based assay is a surveillance option for active cases. Here, we evaluated the feasibility and test performance of a rapid SARS-CoV-2 antigen test during our field activities in 1,100 asymptomatic individuals in Samut Sakhon, Thailand, during the second wave COVID-19 outbreak (December 26–30, 2020). The results showed that the rapid antigen test had a sensitivity of 47.97% (95% CI: 36.10–59.96%) and a specificity of 99.71% (95% CI: 99.15–99.94%) versus standard reverse-transcriptase polymerase chain reaction. The rapid test performed better in cases with higher viral loads determined by the cycle threshold value. In real-world setting, the test performance can be compromised by several factors including viral loads, logistic chains, temperature, technical expertise of the operators, validity, and accuracy of the testing itself. Our study highlights a prerequisite for reevaluation of any given testing before implementing it at the national level.

2020 ◽  
Author(s):  
Abeer Mohamed Abdelrazik ◽  
Shahira Morsy Elshafie ◽  
Hossam M Abdelaziz

Abstract Objective Because of the rapidly emerging SARS-CoV-2 pandemic and its wide public health challenges, rapid diagnosis is essential to decrease the spread. Antigen-based rapid detection tests are available; however, insufficient data about their performance are available. Methods The lateral-flow immunochromatographic BIOCREDIT COVID-19 antigen test was evaluated using nasopharyngeal swabs in a viral transport medium from patients with confirmed infection, contacts, and exposed healthcare professionals at Fayoum University Hospital in Egypt. Test performance was determined in comparison to the SARS-CoV-2 real-time reverse-transcription polymerase chain reaction (RT-PCR) test. Results Three hundred ten specimens from 3 categories—patients with confirmed diagnoses of COVID-19, contacts, and exposed healthcare professionals—were included; 188 specimens were RT-PCR-positive, from which 81 were detected by rapid antigen test. Overall sensitivity was 43.1%. Sensitivity was significantly higher in specimens with high viral loads. Conclusion Poor sensitivity of the BIOCREDIT COVID-19 test does not permit its use for diagnosis, and it can only be used in conjunction with RT-PCR for screening.


2020 ◽  
Author(s):  
Scott Pallett ◽  
Aatish Patel ◽  
Gary Davies ◽  
Luke Moore

Abstract Severe Acute Respiratory Syndrome coronavirus 2 (SARS-CoV-2) has become a global pandemic, causing over 3,600,000 reported cases and 250,000 deaths worldwide.1 Case identification has predominantly been made by real-time polymerase chain reaction (PCR) during the acute phase and largely restricted to healthcare laboratories. Serological assays are emerging but independent validation is urgently required to assess their utility. Where a plurality of point-of-care (POC) SARS-CoV-2 antibody test kits have become available, we will therefore aim to evaluate a range of kits against the current available gold-standard diagnostic test of PCR in an initial, exploratory study. We will then proceed to carry out testing with 200 hospital inpatients using the OrientGene COVID-19 IgG/IgM Rapid Test Cassette against PCR in order to undergo a preliminary evaluation of POC serological test performance characteristics within a hospital inpatient cohort.


2021 ◽  
Author(s):  
Zannat Kawser ◽  
Mohabbat Hossain ◽  
Sara Suliman ◽  
Shahin Lockman ◽  
Jesse Gitaka ◽  
...  

Early detection of SARS-CoV-2 infection is crucial to prevent the spread of the virus. In this study, we evaluated the performance of a commercial rapid antigen detection test, BD Veritor, and compared this (and another rapid test, Standard Q) against a gold-standard of nasopharyngeal (NP) swab tested by reverse transcription-polymerase chain reaction (RT-PCR) in prospectively recruited adults in Dhaka, Bangladesh. We compared the sensitivity and specificity of the two rapid antigen tests against RT-PCR results in 130 symptomatic and 130 asymptomatic adults. In addition, we evaluated the suitability and ease-of-use of the BD Veritor test in a subsample of study participants (n=42) and implementers (n=5). The sensitivity of the BD Veritor rapid antigen 66 test was 70% in symptomatic (95% confidence interval [CI]: 51-85%) and 87% (95% CI: 69-96%) in asymptomatic individuals with positive SARSCoV-2 RT-PCR, for overall sensitivity of 78% (95% CI: 66-88%). The sensitivity of the Standard Q rapid antigen test was 63% (95% CI: 44-69 80%) in symptomatic and 73% (95% CI: 54-87%) in asymptomatic individuals. One false positive in BD Veritor test (specificity 99.5) and no false positive in Standard Q tests were observed (specificity 100%). The BD Veritor rapid antigen test was 78% sensitive when compared with RT-PCR irrespective of the cycle threshold (Ct) levels in this evaluation in Bangladesh. The implementation evaluation data showed good acceptability in the field settings. This warrants large field evaluation as well as use of the rapid antigen test for quick assessment of SARS-CoV-2 for containment of epidemics in the country.


Author(s):  
Mar Masiá ◽  
Marta Fernández-González ◽  
Manuel Sánchez ◽  
Mar Carvajal ◽  
José Alberto García ◽  
...  

Abstract Background Performance of point-of-care tests in different clinical scenarios and on different samples remains undetermined. We comprehensively evaluated the performance of the nasopharyngeal Panbio COVID-19 antigen Rapid-Test-Device. Method Prospective study including consecutive patients attending three primary care centers (PCC) and an emergency department. The antigen test was performed at point-of-care in nasopharyngeal and nasal swabs, and in saliva. Positive and negative percent agreement (PPA, NPA) were calculated with the RT-PCR assay as reference standard. Results Of 913 patients included, 296 (32.3%) were asymptomatic and 690 (75.6%) came from the PCC. Nasopharyngeal swabs were collected from 913, nasal swabs from 659, and saliva from 611 patients. RT-PCR was positive in 196 (21.5%) nasopharyngeal samples (NPS). Overall PPA (95% CI) in NPS was 60.5% (53.3-67.4), and it was lower in nasal swabs (44.7%) and saliva (23.1%). Test performance in NPS was largely dependent on the cycle threshold (Ct) in RT-PCR, with PPA of 94% for Ct≤25 and 80% for Ct<30. In symptomatic patients, the PPA was 95% for Ct≤25; 85% for Ct<30, and 89% for the symptom triad of fever, cough and malaise. Performance was also dependent on age, with PPA of 100% in symptomatic patients >50 years with Ct<25. In asymptomatic patients, the PPA was 86% for Ct<25. In all cases, NPA was 100%. Conclusion The nasopharyngeal Panbio COVID-19 antigen test performed at point-of-care has a good sensitivity in symptomatic patients with Ct<30 and older age. The test was useful to identify asymptomatic patients with lower Ct values.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Jennifer K. Frediani ◽  
Joshua M. Levy ◽  
Anuradha Rao ◽  
Leda Bassit ◽  
Janet Figueroa ◽  
...  

AbstractWhile there has been significant progress in the development of rapid COVID-19 diagnostics, as the pandemic unfolds, new challenges have emerged, including whether these technologies can reliably detect the more infectious variants of concern and be viably deployed in non-clinical settings as “self-tests”. Multidisciplinary evaluation of the Abbott BinaxNOW COVID-19 Ag Card (BinaxNOW, a widely used rapid antigen test, included limit of detection, variant detection, test performance across different age-groups, and usability with self/caregiver-administration. While BinaxNOW detected the highly infectious variants, B.1.1.7 (Alpha) first identified in the UK, B.1.351 (Beta) first identified in South Africa, P.1 (Gamma) first identified in Brazil, B.1.617.2 (Delta) first identified in India and B.1.2, a non-VOC, test sensitivity decreased with decreasing viral loads. Moreover, BinaxNOW sensitivity trended lower when devices were performed by patients/caregivers themselves compared to trained clinical staff, despite universally high usability assessments following self/caregiver-administration among different age groups. Overall, these data indicate that while BinaxNOW accurately detects the new viral variants, as rapid COVID-19 tests enter the home, their already lower sensitivities compared to RT-PCR may decrease even more due to user error.


COVID ◽  
2021 ◽  
Vol 1 (4) ◽  
pp. 784-789
Author(s):  
Fabio Lombardo ◽  
Gianluca Triolo ◽  
Biao Yang ◽  
Zhonghua Liu ◽  
Paolo Maiuri ◽  
...  

Quick and reliable identification of severe acute respiratory syndrome coronavirus SARS-CoV-2 in the population is required to manage the COVID-19 pandemic. This is a prospective observational study of diagnostic accuracy. Paired swab samples from 317 asymptomatic individuals referring to a drive-in testing facility were tested in parallel by means of the rapid antigen test developed by Jiangsu Bioperfectus Technologies and routine nucleic acid detection. Overall specificity was 100% and sensitivity was 49% but reached 87% at higher viral loads (Ct < 25). In this study, the antigen detection test showed high specificity and good sensitivity in asymptomatic individuals carrying higher viral loads. The assay performance worsened with lower viral loads, making it useful when a rapidly deployable test is essential and to assess a potential risk of immediate transmission in the community, but not recommended for testing asymptomatic individuals.


2020 ◽  
Author(s):  
Beatrice M.F. Winkel ◽  
Emma Schram ◽  
Hendrik Gremmels ◽  
Sylvia B. Debast ◽  
Rob Schuurman ◽  
...  

AbstractBackgroundAntigen-based point of care tests for identification of SARS-CoV-2 may markedly enhance effectiveness of population-based controlling strategies. Previous studies have demonstrated acceptable sensitivity and high specificity compared to RT-qPCR in symptomatic individuals, but test performance for asymptomatic individuals is unknown.MethodsTest performance of the Panbio™ COVID-19 Ag Rapid Test (Abbott) was compared to RT-qPCR in a longitudinal cohort study of asymptomatic football players and staff members of professional football clubs. Based on timing of symptoms and prior and subsequent test results, positive RT-qPCR tests were categorized as pre-symptomatic, early or late infection or persistent RNA shedding.Findings2425 tests were performed in 824 individuals, of which 52 (6.3%) were SARS-CoV-2 positive based on RT-qPCR. There were 2406 paired sets from asymptomatic subjects for analysis. Sixteen Panbio™ tests were inconclusive, for which sensitivity analyses were performed (considering results as either positive or negative or being excluded). Sensitivity of Panbio™ ranged from 61.76% (95% CI 49.2-73.3) to 69.12% (95% CI: 56.7-79.8) and specificity from 99.53% (95% CI: 99.2-99.8) to 100% (95% CI: 99.8-100). Sensitivity of Panbio™ to detect subjects with pre-symptomatic/early infection (n= 42) ranged from 81.82% (95% CI: 67.3-91.8) to 90.91% (95% CI: 78.3-97.5) with specificity always above 99%.InterpretationIn asymptomatic subjects the Panbio™ COVID-19 Ag Rapid Test had sensitivity of 81.82% to 90.91% and specificity above 99% for identifying pre-symptomatic and early SARS-CoV-2 infection.FundingThis study was funded by the executing institutes. The Panbio™ COVID-19 Ag Rapid Tests were provided by the Ministry of Health, Welfare and Sport (VWS).


2021 ◽  
Author(s):  
Bàrbara Baro ◽  
Pau Rodo ◽  
Dan Ouchi ◽  
Antoni E. Bordoy ◽  
Emilio N. Saya Amaro ◽  
...  

AbstractBackgroundMass testing for early identification and isolation of infectious COVID-19 individuals, irrespective of concurrent symptoms, is an efficacious strategy to reduce disease transmission. Antigen-detecting rapid diagnostic tests (Ag-RDT) appear as a potentially suitable tool for mass testing on account of their ease-of-use, fast turnaround time, and low cost. However, benchmark comparisons are scarce, particularly in the context of unexposed asymptomatic individuals.MethodsWe used nasopharyngeal specimens from unexposed asymptomatic individuals to assess five Ag-RDTs: PanBio™ COVID-19 Ag Rapid test (Abbott), CLINITEST® Rapid COVID-19 Antigen Test (Siemens), SARS-CoV-2 Rapid Antigen Test (Roche Diagnostics), SARS-CoV-2 Antigen Rapid Test Kit (Lepu Medical), and COVID-19 Coronavirus Rapid Antigen Test Cassette (Surescreen). Samples were collected between December 2020-January 2021 during the third wave of the epidemic in Spain.FindingsThe analysis included 101 specimens with confirmed positive PCR results and 185 with negative PCR. For the overall sample, the performance parameters of Ag-RDTs were as follows: Abbott assay, sensitivity 38·6% (95% CI 29·1–48·8) and specificity 99·5% (97–100%); Siemens, sensitivity 51·5% (41·3–61·6) and specificity 98·4% (95·3–99·6); Roche, sensitivity 43·6% (33·7–53·8) and specificity 96·2% (92·4–98·5); Lepu, sensitivity 45·5% (35·6–55·8) and specificity 89·2% (83·8–93·3%); Surescreen, sensitivity 28·8% (20·2–38·6) and specificity 97·8% (94·5–99·4%). For specimens with cycle threshold (Ct) <30 in RT-qPCR, all Ag-RDT achieved a sensitivity of at least 70%, with Siemens, Roche, and Lepu assays showing sensitivities higher than 80%. In models according to population prevalence, all Ag-RDTs will have a NPV >99% and a PPV<50% at 1% prevalence.InterpretationTwo commercial, widely available assays can be used for SARS-CoV-2 antigen testing to achieve sensitivity in specimens with a Ct<30 and specificity of at least 80% and 96%, respectively. Estimated negative and positive predictive values suggests the suitability of Ag-RDTs for mass screenings of SARS-CoV-2 infection in the general population.FundingBlueberry diagnostics, Fundació Institut d’Investigació en Ciències de la Salut Germans Trias i Pujol, and #YoMeCorono.org crowdfunding campaign.Research in contextEvidence before this studyIn December 2020, we searched on PubMed for articles containing the terms “antigen”, “test” (or Ag-RDT), and “SARS-CoV-2” or “COVID-19” either in the title or the abstract. Our search yielded 79 entries corresponding to articles written in English. Of them, 33 were articles presenting the diagnostic performance of qualitative lateral-flow antigen-detecting rapid diagnostic tests (Ag-RDT). Four of these articles reported the results of head-to-head comparisons of various Ag-RDTs; in all cases, the number of tests was lower than the recommended for retrospective assessments of diagnostic performance (i.e., minimum of 100 PCR positive and 100 PCR negative). Furthermore, all head-to-head comparisons found in the literature included specimens obtained among individuals with varying disease status (none of which asymptomatic), thus limiting the adequacy of the estimates for an asymptomatic screening strategy.Added value of this studyWe compared for the first time head-to-head five Ag-RDT using a powered set of fresh respiratory specimens PCR-confirmed positive or negative, collected from unexposed asymptomatic individuals during screening campaigns for early detection of SARS-CoV-2 infection. The sample size was large enough to draw robust conclusions. Our analysis identified four Ag-RDTs (i.e., assays marketed by Abbott, Siemens, Roche, and Surescreen) with specificity higher than 96%. Despite the low sensitivity for the overall sample (range 29% to 51%), the corresponding values for the subset of samples with Ct <30 were higher than 80% for Siemens, Roche, and Lepu assays. The estimated NPV for a screening performed in an area with 1% prevalence would be >99% for all tests, while the PPV would be <50%.Implications of all the available evidenceCurrent data on the diagnostic performance of Ag-RDTs is heterogeneous and precludes benchmark assessments. Furthermore, the screening of asymptomatic populations is currently not considered among the intended uses of Ag-RDT, mostly because of lack of evidence on test performance in samples from unexposed asymptomatic individuals. Our findings add to the current evidence in two ways: first, we provide benchmarking data on Ag-RDTs, assessed head-to-head in a single set of respiratory specimens; second, we provide data on the diagnostic performance of Ag-RDTs in unexposed asymptomatic individuals. Our findings support the idea that Ag-RDTs can be used for mass screening in low prevalence settings and accurately rule out a highly infectious case in such setting.


2020 ◽  
Vol 7 (Supplement_1) ◽  
pp. S280-S280
Author(s):  
Sanjat Kanjilal ◽  
Meghan Baker ◽  
Ann E Woolley ◽  
Chanu Rhee ◽  
Athena K Petrides ◽  
...  

Abstract Background Growing recognition of the importance of asymptomatic and pre-symptomatic transmission for severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) has led to a substantial expansion of testing from symptomatic to asymptomatic patients, and particularly those with risk factors for infection. Viral burden in asymptomatic individuals can differ from symptomatic patients, which can impact test performance. We therefore evaluated the impact of expanded testing indications upon the sensitivity and specificity of molecular diagnostic assays for SARS-CoV-2. Methods We performed a retrospective review of laboratory results from 5,122 emergency room patients and inpatients tested for SARS-CoV-2 between 05/03/2020 and 06/13/2020 using the Hologic Panther Fusion and the Cepheid Xpert assays at the Brigham & Women’s Hospital in Boston, MA. Descriptive analyses were performed for trends in testing volume, rates of positivity and cycle thresholds (Cts) over time based on symptom status. We calculated the proportion of new diagnoses made on a patient’s first test as an indirect measure of sensitivity. We calculated the proportion of first tests that are positive with a Ct value &lt; 35 as an indirect measure of specificity. Results The overall rate of positivity over the study period was 8.7% (599/7,510 tests; 440/4,795 people) and declined by 1.8% (95% CI -2.2% - -1.4%, P&lt; 0.0001) each week. Relative to tests in symptomatic people, the asymptomatic population had a higher mean Ct value (35.1 vs 32.3; P &lt; 0.0001). Ct values increased by 0.7 (95% CI -0.1 - +1.4, P=0.07) and 0.8 (95% CI +0.3 - +1.4; p=0.01), sensitivity declined by 4% (95% CI -9% - +1%, P=0.08) and 12% (95% CI -20% - -5%, P-0.01) and specificity declined by 8% (95% CI -3% to 20%; P=0.13) and 9% (95% CI 7% - 11%; P=0.0002), over the time period of the study for asymptomatic and symptomatic patients, respectively. Figure 1: Trends in Ct values by symptoms Figure 2: Trends in diagnosis by first versus second test by symptoms Figure 3: Trends in proportion of people with their first test having Ct &lt; 35 by symptoms Conclusion We show that the proportion of patients with low SARS-CoV-2 viral loads has increased as testing has expanded to the asymptomatic population and as transmission wanes in the community. This negatively impacts the performance of molecular assays by increasing the risk of false negatives and the detection of non-viable virus. Decision algorithms based on molecular assay results may need re-evaluation in light of these dynamics. Disclosures All Authors: No reported disclosures


BMJ Open ◽  
2021 ◽  
Vol 11 (10) ◽  
pp. e048206
Author(s):  
Beatrice Winkel ◽  
Emma Schram ◽  
Hendrik Gremmels ◽  
Sylvia Debast ◽  
Rob Schuurman ◽  
...  

BackgroundAntigen-based point-of-care tests for identification of SARS-CoV-2 may markedly enhance effectiveness of population-based controlling strategies. Previous studies have demonstrated >70% sensitivity and high specificity compared with reverse transcriptase real-time PCR (RT-PCR) in symptomatic individuals, but test performance for asymptomatic individuals is unknown.MethodsTest performance of the Panbio COVID-19 Ag Rapid Test (Abbott) was compared with RT-PCR in a longitudinal cohort study of asymptomatic football players and staff members of professional football clubs. Based on timing of symptoms and prior and subsequent test results, positive RT-PCR tests were categorised as presymptomatic, early or late infection, or persistent RNA shedding.Findings2425 tests were performed in 824 individuals, of which 52 (6.3%) were SARS-CoV-2 positive based on RT-PCR. There were 2406 paired sets from asymptomatic subjects for analysis. Sixteen Panbio tests were inconclusive, for which sensitivity analyses were performed (considering results as either positive or negative or being excluded). Sensitivity of Panbio for screening of asymptomatic individuals ranged from 80.0% (61.4–92.3) to 86.67% (69.2–96.2) and specificity from 99.53% (95% CI 99.2 to 99.8) to 100% (95% CI 99.8 to 100). Sensitivity of Panbio to detect subjects with presymptomatic/early infection (n=42) ranged from 81.82% (95% CI 67.3 to 91.8) to 90.91% (95% CI 78.3 to 97.5) with specificity always above 99%.InterpretationThe Panbio COVID-19 Ag rapid test identifies 81%–90% of presymptomatic and early asymptomatic SARS-CoV-2 infections with high specificity. This test may therefore be adopted in testing strategies such as targeted screening of specific populations where prevalence is low.


Sign in / Sign up

Export Citation Format

Share Document