Evaluation of Flexural Performance of Truss Encased Slab with Compression Elements Composed of U-shaped Steel and Filling Concrete under Permanent Load

2020 ◽  
Vol 32 (3) ◽  
pp. 233-240
Author(s):  
Mun-Gil Kim ◽  
Sung-Chul Chun ◽  
Young Ho Kim
2019 ◽  
Vol 7 (12) ◽  
pp. 1295-1307
Author(s):  
Xizhi Wu ◽  
Xueyou Huang ◽  
Xianjun Li ◽  
Yiqiang Wu

2020 ◽  
Vol 38 (5A) ◽  
pp. 669-680
Author(s):  
Ghazwan K. Mohammed ◽  
Kaiss F. Sarsam ◽  
Ikbal N. Gorgis

The study deals with the effect of using Slurry infiltrated fiber concrete (SIFCON) with the reinforced concrete beams to explore its enhancement to the flexural capacity. The experimental work consists of the casting of six beams, two beams were fully cast by conventional concrete (CC) and SIFCON, as references. While the remaining was made by contributing a layer of SIFCON diverse in-depth and position, towards complete the overall depths of the built-up beam with conventional concrete CC. Also, an investigation was done through the control specimens testing about the mechanical properties of SIFCON. The results showed a stiffer behavior with a significant increase in load-carrying capacity when SIFCON used in tension zones. Otherwise high ductility and energy dissipation appeared when SIFCON placed in compression zones with a slight increment in ultimate load. The high volumetric ratio of steel fibers enabled SIFCON to magnificent tensile properties.


Materials ◽  
2021 ◽  
Vol 14 (11) ◽  
pp. 2809
Author(s):  
Md. Akter Hosen ◽  
Fadi Althoey ◽  
Mohd Zamin Jumaat ◽  
U. Johnson Alengaram ◽  
N. H. Ramli Sulong

Reinforced concrete (RC) structures necessitate strengthening for various reasons. These include ageing, deterioration of materials due to environmental effects, trivial initial design and construction, deficiency of maintenance, the advancement of design loads, and functional changes. RC structures strengthening with the carbon fiber reinforced polymer (CFRP) has been used extensively during the last few decades due to their advantages over steel reinforcement. This paper introduces an experimental approach for flexural strengthening of RC beams with Externally-Side Bonded Reinforcement (E-SBR) using CFRP fabrics. The experimental program comprises eight full-scale RC beams tested under a four-point flexural test up to failure. The parameters investigated include the main tensile steel reinforcing ratio and the width of CFRP fabrics. The experimental outcomes show that an increase in the tensile reinforcement ratio and width of the CFRP laminates enhanced the first cracking and ultimate load-bearing capacities of the strengthened beams up to 141 and 174%, respectively, compared to the control beam. The strengthened RC beams exhibited superior energy absorption capacity, stiffness, and ductile response. The comparison of the experimental and predicted values shows that these two are in good agreement.


2021 ◽  
pp. 136943322110093
Author(s):  
Jinqing Jia ◽  
Qi Cao ◽  
Lihua Zhang ◽  
Jiayu Zhou

Concrete made by post-filling coarse aggregate process could reduce the cement content greatly compared with traditional concrete placement method. Thus, it not only lowers the production cost of concrete through lower usage of cement but also reduces the CO2 emissions to the environment. In this paper, the compressive and tensile strength of post-filling coarse aggregate concrete with different post-filling ratios (PFRs) (0%, 10%, 15%, 20%, 25%, 30%) and concrete strength grades (C30, C40, C50) were first studied. Then the flexural performance of nineteen concrete beams with different concrete strength, post-filling ratios, reinforcement ratios was investigated. The experimental results showed that the compressive strength and elastic modulus of the post-filling coarse aggregate concrete increased with the increase of the post-filling ratio of coarse aggregate, reaching the peak value at the filling ratio of 20%. It indicated that there was no obvious difference in the failure mode as well as middle-span deflections between post-filling coarse aggregate concrete (PFCC) beams and ordinary concrete (OC) beams. Ductile failure was observed for all nineteen specimens. Results demonstrated that the cracking load, yield load, and ultimate load of the post-filling coarse aggregate concrete beams all reached the peak value at the post-filling ratio of 20%. In addition, the theoretical predictions of cracking loads and ultimate load carrying capacities matched the experimental results in satisfactory agreement.


Author(s):  
Yanuar Haryanto ◽  
Ay Lie Han ◽  
Hsuan-Teh Hu ◽  
Fu-Pei Hsiao ◽  
Banu Ardi Hidayat ◽  
...  

Structures ◽  
2020 ◽  
Vol 27 ◽  
pp. 2034-2047
Author(s):  
Jin-Yang Chen ◽  
Fa-Cheng Wang ◽  
Lin-Hai Han ◽  
Ting-Min Mu
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document