scholarly journals COMBINED CALCULATION OF RADIATION FROM LARGE-SIZED GROUND RW STORAGE FACILITIES ON THE BASIS OF MONTE CARLO METHOD

2019 ◽  
pp. 69-74
Author(s):  
V.G. Rudychev ◽  
N.A. Azarenkov ◽  
I.O. Girka ◽  
D.V. Rudychev ◽  
Y.V. Rudychev

A technique to reduce the dose rates, produced by large-sized ground-based radiation sources with dozens of radiating elements of the same geometry arranged along the perimeter, is developed. The radiating elements represent the concrete rectangular casks into which cylindrical barrels filled with compacted RW are loaded. The spatial distribution of the radiation around the cask is calculated by the Monte Carlo method. The radiation is assumed to be produced by the definite radionuclides of RW. Shielding by neighboring containers and the presence of an additional biological shielding are taken into account. Different options of the container arrangement are considered.

2021 ◽  
Vol 24 (2) ◽  
pp. 67
Author(s):  
Rasito Tursinah ◽  
Bunawas Bunawas ◽  
Tri Cahyo ◽  
Ade Suherman ◽  
P Sukmabuana

In the development of low-medium energy photon calibration facilities we have simulated several types of gamma irradiator collimator materials with ISO 4037-1 design connected to the output beam spectrum and the resulting kerma. Four types of collimator material, namely Al, Fe, Pb, and WCu have been simulated with gamma radiation sources 241Am, 57Co, 137Cs, and 60Co. Simulations were carried out using the Monte Carlo method with the PHITS computer program. Based on the comparison of air kerma produced, collimators made from Al are suitable for gamma sources 241Am, Fe material for gamma sources 57Co, and Pb material for sources 137Cs and 60Co.


2014 ◽  
Vol 29 (1) ◽  
pp. 34-39
Author(s):  
Alireza Karimian ◽  
Amir Beheshti ◽  
Mohammadreza Abdi ◽  
Iraj Jabbari

Exposure to radiation is one of the main sources of risk to staff employed in reactor facilities. The staff of a tokamak is exposed to a wide range of neutrons and photons around the tokamak hall. The International Thermonuclear Experimental Reactor (ITER) is a nuclear fusion engineering project and the most advanced experimental tokamak in the world. From the radiobiological point of view, ITER dose rates assessment is particularly important. The aim of this study is the assessment of the amount of radiation in ITER during its normal operation in a radial direction from the plasma chamber to the tokamak hall. To achieve this goal, the ITER system and its components were simulated by the Monte Carlo method using the MCNPX 2.6.0 code. Furthermore, the equivalent dose rates of some radiosensitive organs of the human body were calculated by using the medical internal radiation dose phantom. Our study is based on the deuterium-tritium plasma burning by 14.1 MeV neutron production and also photon radiation due to neutron activation. As our results show, the total equivalent dose rate on the outside of the bioshield wall of the tokamak hall is about 1 mSv per year, which is less than the annual occupational dose rate limit during the normal operation of ITER. Also, equivalent dose rates of radiosensitive organs have shown that the maximum dose rate belongs to the kidney. The data may help calculate how long the staff can stay in such an environment, before the equivalent dose rates reach the whole-body dose limits.


2020 ◽  
Vol 2020 (4) ◽  
pp. 25-32
Author(s):  
Viktor Zheltov ◽  
Viktor Chembaev

The article has considered the calculation of the unified glare rating (UGR) based on the luminance spatial-angular distribution (LSAD). The method of local estimations of the Monte Carlo method is proposed as a method for modeling LSAD. On the basis of LSAD, it becomes possible to evaluate the quality of lighting by many criteria, including the generally accepted UGR. UGR allows preliminary assessment of the level of comfort for performing a visual task in a lighting system. A new method of "pixel-by-pixel" calculation of UGR based on LSAD is proposed.


Author(s):  
V.A. Mironov ◽  
S.A. Peretokin ◽  
K.V. Simonov

The article is a continuation of the software research to perform probabilistic seismic hazard analysis (PSHA) as one of the main stages in engineering seismic surveys. The article provides an overview of modern software for PSHA based on the Monte Carlo method, describes in detail the work of foreign programs OpenQuake Engine and EqHaz. A test calculation of seismic hazard was carried out to compare the functionality of domestic and foreign software.


2019 ◽  
Vol 20 (12) ◽  
pp. 1151-1157 ◽  
Author(s):  
Alla P. Toropova ◽  
Andrey A. Toropov

Prediction of physicochemical and biochemical behavior of peptides is an important and attractive task of the modern natural sciences, since these substances have a key role in life processes. The Monte Carlo technique is a possible way to solve the above task. The Monte Carlo method is a tool with different applications relative to the study of peptides: (i) analysis of the 3D configurations (conformers); (ii) establishment of quantitative structure – property / activity relationships (QSPRs/QSARs); and (iii) development of databases on the biopolymers. Current ideas related to application of the Monte Carlo technique for studying peptides and biopolymers have been discussed in this review.


Sign in / Sign up

Export Citation Format

Share Document