scholarly journals 2d Image Features Detector and Descriptor Selection Expert System

Author(s):  
Ibon Merino ◽  
Jon Azpiazu ◽  
Anthony Remazeilles ◽  
Basilio Sierra
Author(s):  
J.R. Parsons ◽  
C.W. Hoelke

The direct imaging of a crystal lattice has intrigued electron microscopists for many years. What is of interest, of course, is the way in which defects perturb their atomic regularity. There are problems, however, when one wishes to relate aperiodic image features to structural aspects of crystalline defects. If the defect is inclined to the foil plane and if, as is the case with present 100 kV transmission electron microscopes, the objective lens is not perfect, then terminating fringes and fringe bending seen in the image cannot be related in a simple way to lattice plane geometry in the specimen (1).The purpose of the present work was to devise an experimental test which could be used to confirm, or not, the existence of a one-to-one correspondence between lattice image and specimen structure over the desired range of specimen spacings. Through a study of computed images the following test emerged.


Author(s):  
W. Krakow ◽  
D. A. Smith

The successful determination of the atomic structure of [110] tilt boundaries in Au stems from the investigation of microscope performance at intermediate accelerating voltages (200 and 400kV) as well as a detailed understanding of how grain boundary image features depend on dynamical diffraction processes variation with specimen and beam orientations. This success is also facilitated by improving image quality by digital image processing techniques to the point where a structure image is obtained and each atom position is represented by a resolved image feature. Figure 1 shows an example of a low angle (∼10°) Σ = 129/[110] tilt boundary in a ∼250Å Au film, taken under tilted beam brightfield imaging conditions, to illustrate the steps necessary to obtain the atomic structure configuration from the image. The original image of Fig. 1a shows the regular arrangement of strain-field images associated with the cores of ½ [10] primary dislocations which are separated by ∼15Å.


Author(s):  
W.W. Adams ◽  
G. Price ◽  
A. Krause

It has been shown that there are numerous advantages in imaging both coated and uncoated polymers in scanning electron microscopy (SEM) at low voltages (LV) from 0.5 to 2.0 keV compared to imaging at conventional voltages of 10 to 20 keV. The disadvantages of LVSEM of degraded resolution and decreased beam current have been overcome with the new generation of field emission gun SEMs. In imaging metal coated polymers in LVSEM beam damage is reduced, contrast is improved, and charging from irregularly shaped features (which may be unevenly coated) is reduced or eliminated. Imaging uncoated polymers in LVSEM allows direct observation of the surface with little or no charging and with no alterations of surface features from the metal coating process required for higher voltage imaging. This is particularly important for high resolution (HR) studies of polymers where it is desired to image features 1 to 10 nm in size. Metal sputter coating techniques produce a 10 - 20 nm film that has its own texture which can obscure topographical features of the original polymer surface. In examining thin, uncoated insulating samples on a conducting substrate at low voltages the effect of sample-beam interactions on image formation and resolution will differ significantly from the effect at higher accelerating voltages. We discuss here sample-beam interactions in single crystals on conducting substrates at low voltages and also present the first results on HRSEM of single crystal morphologies which show some of these effects.


1993 ◽  
Vol 2 (4) ◽  
pp. 223 ◽  
Author(s):  
Wang Chengen ◽  
Zhu Jianying ◽  
Wei Zhongxin
Keyword(s):  

1987 ◽  
Vol 26 (01) ◽  
pp. 13-23 ◽  
Author(s):  
H. W. Gottinger

AbstractThe purpose of this paper is to report on an expert system in design that screens for potential hazards from environmental chemicals on the basis of structure-activity relationships in the study of chemical carcinogenesis, particularly with respect to analyzing the current state of known structural information about chemical carcinogens and predicting the possible carcinogenicity of untested chemicals. The structure-activity tree serves as an index of known chemical structure features associated with carcinogenic activity. The basic units of the tree are the principal recognized classes of chemical carcinogens that are subdivided into subclasses known as nodes according to specific structural features that may reflect differences in carcinogenic potential among chemicals in the class. An analysis of a computerized data base of known carcinogens (knowledge base) is proposed using the structure-activity tree in order to test the validity of the tree as a classification scheme (inference engine).


Sign in / Sign up

Export Citation Format

Share Document