scholarly journals Forensic Engineering Analysis of an Explosion Allegedly Caused by an Overfilled Propane Cylinder

Author(s):  
Jerry R. Tindal

Analyzing the origin and cause of fires or explosions for the purposes of legal proceedings requires the smooth integration of a reliable fire investigative methodology with sound engineering principles and practices. The origin of a building fire was first determined based on the methodology of NFPA 921 Guide for Fire and Explosion Investigations. Engineering analysis was applied to witness observations, arc mapping, fire dynamics, and the evaluation of fire patterns. The fire cause was then evaluated considering NFPA 921 and integrated applied engineering analysis and calculations. The allegations of an overfilled propane cylinder as the cause of the fire were considered. Spoliation issues, poor investigation methodology, and the lack of sound engineering principles (resulting in unreliable opinions) are also contrasted and discussed.

Author(s):  
David Icove ◽  
Thomas R. May

NFPA 921 Guide for Fire and Explosion Investigations considers the technique arc mapping to be one of the methodologies used in isolating a fire’s origin and spread. Provided the technique is used properly and understanding its limitations, it is a tool for investigators. Synthesized here is the latest peer-reviewed research and discussions on the implications of increased use of ground- and arc-fault circuit interrupters on arc mapping analysis. Incorporated are case studies and evaluations of recent legal decisions. The goal is to arm investigators with what’s needed to maximize the arc mapping’s efficacy and best present its use and results.


Author(s):  
Roger L. Owens

In A Case Involving A Residential Fire With Fatalities, Plaintiff Experts Alleged That The Fire Originated In A Bedroom As A Result Of An Electrical Failure In An Oscillating Pedestal Fan. At The Time Of The Fire, The Fan Was Plugged Into A Six Foot Extension Cord That Was Lying On The Floor Under The Bed And Plugged Into A Standard 115 Volt Duplex Receptacle. The Plaintiffs, Specific In Their Allegations, Opined That The Failure Occurred In The Rotary Switch That Controlled The Speed Of The Fan Even Though No Physical Evidence Of A Failure Of That Nature Was Identified Or Collected During The Analyses Of The Fire Scene. Since No Physical Evidence Of A Failure Was Identified, Nfpa 921, Guide For Fire & Explosion Investigations, Requires That All Other Potential Ignition Sources In The Area Of Origin Be Eliminated As A Possible Cause. Plaintiffs Eliminated The Power Cord For The Fan, The Extension Cord And The Cord Plug And Cord Receptacle Connection Under The Theory That The Material Was Pvc With A Vw-1 Fire Rating. Plaintiffs Testified That The Self Extinguishing Characteristics Of Vw-1 Material Were Such That, Even With An Electrical Failure In One Of Those Components That Resulted In The Ignition Of The Material, There Would Be Insufficient Heat Released To Ignite The Box Spring For The Bed. Plaintiffs Also Eliminated Improperly Discarded Smoking Material As A Potential Cause.Efendants Were In Sharp Disagreement With Plaintiff Case In Chief Regarding The Elimination Of The Vw-1 Materials As A Potential Fire Cause, Since The Material Will Combust In Situations With A Sustained Electrical Fault. Defendants Conducted Tests Which Not Only Demonstrated An Electrical Failure With Ignition At The Extension Cord Plug Receptacle Interface, But Also That The Burning Vw-1 Pvc Released Sufficient Heat Energy To Ignite A Box Spring Similar To The Box Spring Involved In The Fire. The Results Of Those Tests Assisted In The Resolution Of The Case Prior To Trial.


Author(s):  
William E. DeWitt

National Fire Protection Association (Nfpa) Guide 921 Was Published In 1992. Nfpa 921 Is Entitled; Guide For Fire And Explosion Investigations. This Paper Will Review Nfpa 921 And Analyze Its Significant Impact On The Field Of Forensic Engineering. Future Revisions And Planned Additions To The Document Which Affect Forensic Engineering Will Also Be Discussed.


Author(s):  
D.S. Sax Saxena ◽  
Saxena Anu

The Influence Of Construction And Pile Driving Vibrations On Surrounding Buildings, Including Hospitals And Eye Examination Facilities, Sensitive Devices Such As Computers And Surgical Microscopes Or Electronic Machines, And People In The Urban Environment Is A Significant Consideration In Obtaining Project Approvals From Appropriate Agencies And Authorities. Implementation Of Construction Projects In Areas Adjacent To Existing Buildings (Aged, Historical, Residential, Commercial, Industrial, Medical Services, Or Electronic Services) Creates Additional Difficulties. Specialized Case History Is Presented Where Damage To Sensitive Structures From A Variety Of Vibratory Construction Methods Ranging From Pile Driving, Highway Construction, Rock Excavation And/Or Blasting, Was Considered. Twenty Homeowners From A Residential Subdivision In The Florida Panhandle, Claimed Damage Including Cracking To Their Properties During Construction Of Various Portions Of City Storm Water Treatment/Enhancement Project. It Was Also Alleged That During Excavation And Construction Of Drainage Structures, Especially Four Subsurface Treatment Vaults That Required Installation And Extraction Of Sheet Piles Using Vibratory Hammer, Stability Of The Nearby Residential Structures Was Endangered And Resulted In Movement/Cracking. Forensic Engineering Analysis Was Effectively Utilized To Identify, Investigate, And Remediate The Concerns As Well As Assist In Litigation And In Some Cases Avoidance. This Technical Paper Presents Some Legal Issues Related To Litigation, Mediation, And Resolution Involving Jurisprudence System And Introduces A Case History That Includes All Elements Of Forensic Engineering.


Author(s):  
Curtis E. Falany

Lightning Is A Powerful And Dangerous Natural Force. It Is Capable Of Inflicting Significant Damage To Our Environment And Causing Injury Or Death In Living Organisms. Electrical And Electronic Circuits Are Particularly Susceptible To Lightning, Both From Direct Strikes And From Lightning Induced Electrical Surges. Fires Often Result From Lightning Strikes. Injury And Death Can Result From Both Direct Strikes, Lightning Induced Electrical Surges, And Indirectly From Structure Damage And Fires. The Insurance In-Dustry Offers Coverage For Lighting Related Losses And A Forensic Engineer Is Often Consulted To Assist In Adjusting The Claim.


Author(s):  
Michael Kravitz

This paper examines the effect of a pedestrian inadvertently impacting a glass panel adjacent to a glass exit door. The glass panel was full length and unmarked, violating the local building code and building commissioner directives. The defense argued that the old building code, to which the college building was constructed, was “grandfathered” and there was no violation. Initial witness and plaintiff statements indicated that the plaintiff was running when he struck the panel, which shattered and caused the plaintiff to incur injuries. The plaintiff testified later, in deposition, that he was walking when he struck the glass. The court needed to establish liability percentage, which is common in civil cases, and it was necessary to determine at what pedestrian impact speed the glass panel would break. The analysis used Timoshenko’s theory of vibration plates, Roark’s stress strain formulas, ergonomics, and human factors to estimate the impact load and stresses on the glass panel that caused failure.


Sign in / Sign up

Export Citation Format

Share Document