scholarly journals Utilization of UPLC-tandem mass spectrometry for quantitation of colouring matters in dietary formulation

2019 ◽  
Vol 10 (3) ◽  
pp. 239-243
Author(s):  
Wafaa Abdou Zaghary ◽  
Ahmed Mostafa Abdalla ◽  
Emily Tawfik Hanna ◽  
Marwa Abdel Rahman Tohamy Zanoun

A simple and sensitive ultra-performance liquid chromatography with Tandem Mass Spectrometric detection (UPLC-MS/MS) method was developed and validated for the simultaneous quantitation of two food colouring matters, Curcumin (CUR) and Riboflavin (RIB). Chromatographic separation was done on Hypersil gold 50×2.1 mm (1.9 μm) column, with gradient programing of mobile phase starting with aqueous 0.1% formic acid and increasing the percentage of 0.1% formic acid in acetonitrile. The utilization of multiple reaction monitoring (MRM) improved the selectivity of detection and decreased the matrix effect.  The method was linear in the range of 5-500 ng/mL for CUR and RIB. Intra- and inter-day reproducibility were within the accepted criteria. The method was successfully applied for the determination the laboratory prepared mixtures of the two selected colouring matters. The use of mass spectrometry enhanced the selectivity and sensitivity of detection which allows the robust use of the method in routine quality control tests of the two colouring matters (CUR and RIB).


2019 ◽  
Vol 15 (7) ◽  
pp. 710-715
Author(s):  
S.T. Narenderan ◽  
Basuvan Babu ◽  
T. Gokul ◽  
Subramania Nainar Meyyanathan

Objective: The aim of the present work is to achieve a novel highly sensitive chromatographic method for the simultaneous determination of hepatitis C agents, sofosbuvir and velpatasvir from human plasma using ritonavir as an internal standard. Methods: Chromatographic separation was achieved using Hypersil C18 column (50mm x 4.6mm, 3μm) with an isocratic elution mode using the mobile phase composition 10 mM ammonium formate buffer (pH 5.0): acetonitrile (20:80 v/v) pumped at a flow rate of 0.5 ml/min. The detection was carried out by tandem mass spectrometry using Multiple Reaction Monitoring (MRM) positive Electrospray Ionization (ESI) with proton adducts at m/z 530.10 > 243.10, 883.40 > 114.0 and 721.25 > 197.0. Results: The method validated as per USFDA guidelines with respect to linearity, accuracy, and precision was found to be acceptable over the concentration range of 0.2–2000 ng/ml and 5-2000 ng/ml for sofosbuvir and velpatasvir respectively and the method was found to be highly sensitive and selective. Conclusion: The developed tandem mass spectrometric method is robust and can be applied for the monitoring of plasma levels of the analyzed drug in preclinical and clinical pharmacokinetic studies.



2018 ◽  
Vol 90 (9) ◽  
pp. 5627-5636 ◽  
Author(s):  
Anna Illiano ◽  
Valentina Arpino ◽  
Gabriella Pinto ◽  
Andrea Berti ◽  
Vincenzo Verdoliva ◽  
...  


Sign in / Sign up

Export Citation Format

Share Document