scholarly journals Quantifying fugitive gas emissions from an oil sands tailings pond with open-path Fourier transform infrared measurements

2021 ◽  
Vol 14 (2) ◽  
pp. 945-959
Author(s):  
Yuan You ◽  
Samar G. Moussa ◽  
Lucas Zhang ◽  
Long Fu ◽  
James Beck ◽  
...  

Abstract. Fugitive emissions from tailings ponds contribute significantly to facility emissions in the Alberta oil sands, but details on chemical emission profiles and the temporal and spatial variability of emissions to the atmosphere are sparse, since flux measurement techniques applied for compliance monitoring have their limitations. In this study, open-path Fourier transform infrared spectroscopy was evaluated as a potential alternative method for quantifying spatially representative fluxes for various pollutants (methane, ammonia, and alkanes) from a particular pond, using vertical-flux-gradient and inverse-dispersion methods. Gradient fluxes of methane averaged 4.3 g m−2 d−1 but were 44 % lower than nearby eddy covariance measurements, while inverse-dispersion fluxes agreed to within 30 %. With the gradient fluxes method, significant NH3 emission fluxes were observed (0.05 g m−2 d−1, 42 t yr−1), and total alkane fluxes were estimated to be 1.05 g m−2 d−1 (881 t yr−1), representing 9.6 % of the facility emissions.

2020 ◽  
Author(s):  
Yuan You ◽  
Samar G. Moussa ◽  
Lucas Zhang ◽  
Long Fu ◽  
James Beck ◽  
...  

Abstract. Fugitive emissions from tailings ponds contribute significantly to facility emissions in the Alberta Oil Sands, but details on chemical emission profiles and the temporal and spatial variability of emissions to the atmosphere are sparse, since flux measurement techniques applied for compliance monitoring have their limitations. In this study, open-path Fourier transform infrared spectroscopy was evaluated as a potential alternative method for quantifying spatially representative fluxes for various pollutants (methane, ammonia, and alkanes) from a particular pond, using vertical flux gradient and inverse dispersion methods. Gradient fluxes of methane averaged 3.7 g m−2 d−1 but were 40 % lower than nearby eddy covariance measurements, while inverse dispersion fluxes agreed to within 11 %. Significant NH3 emission fluxes were observed (0.11 g m−2 d−1 (92 tonnes y−1)), and total alkane fluxes were estimated to be 1.33 g m−2 d−1 (1120 tonnes y−1), representing 12 % of the facility emissions.


2005 ◽  
Vol 44 (11) ◽  
pp. 2189 ◽  
Author(s):  
Klaus Schäfer ◽  
Klaus Brockmann ◽  
Jörg Heland ◽  
Peter Wiesen ◽  
Carsten Jahn ◽  
...  

1980 ◽  
Vol 34 (2) ◽  
pp. 171-173 ◽  
Author(s):  
D. G. Mead

Low temperature Fourier transform infrared measurements at 20 K on some wafers containing substitutional atomic carbon and oxygen are presented. Spectral subtraction techniques at 20 K indicate an increase of approximately 5 times in sensitivity compared to the room temperature evaluation of the carbon and oxygen concentrations.


2007 ◽  
Vol 42 (8) ◽  
pp. 1131-1140 ◽  
Author(s):  
Chang-Fu Wu ◽  
Yen-Ling Chen ◽  
Chih-Chieh Chen ◽  
Tzu-Ting Yang ◽  
Pao-Erh Chang

Sign in / Sign up

Export Citation Format

Share Document