In-situ analysis of 1.9 Ga chert with a miniature mass spectrometer for space

2020 ◽  
Author(s):  
Rustam Lukmanov ◽  
Marek Tulej ◽  
Valentine Riedo ◽  
Niels Ligterink ◽  
Coenraad De Koning ◽  
...  

<p>In-situ Mars exploration requires new promising instrumentation that will be capable of delivering highly accurate chemical information about soils and rocks present at the Martian surface. Specific attention is drawn to the instruments that are capable of identifying extinct or extant microbes within the bulk of various solid samples (Tulej et al., 2015; Westall et al., 2015; Wiesendanger et al., 2018). A miniature Laser Ablation/Ionization Mass Spectrometer (LIMS) developed at the University of Bern is among the valid candidates (Wurz et al., 2012). The size of the mass analyzer is only Ø 60 mm × 160 mm and thus capable of being deployed on a rover or lander platform. In this contribution, we will present data collected from a 1.88 Ga Gunflint sample using a deep UV fs laser system as ablation ion source. The gunflint chert sample contains a population of microfossils entombed in the silica matrix and was chosen as a Martian analogue. Using the high stability of the UV laser and consequent uniform ablation, we performed large-scale spectra collection (90’000) in two modes - chemical imaging and depth profiling. With the current setup, we achieved a diameter of the analytical spot of ~10 µm for the depth profiling and ~5 µm for the imaging. Our results reveal that our LIMS instrument can identify the location of the microfossil lamination area as well as single microfossils by chemical means. We show how single mass unit spectral decomposition and subsequent kernel clustering reveal masses and intensity regions unique to the microfossils and inorganic host, thus providing the opportunity for automated identification of the spectra that are collected from the microfossils. We also show how transforming spectral intensities into spectral proximities can help to navigate the rich multidimensional datasets. We also address common interpretation problems in LIMS, when multiple mineralogical inclusions contribute to the output spectra acquired within the single analytical spot using ρ-networks and Principal Component Analysis (PCA). In combination with analysis of spectral proximities, this approach is particularly useful in attempts to assess the biogenicity of the putative terrestrial microfossils as well as potential Martian microfossils. Additionally, we discuss the data analysis pipeline and chemical composition of the microfossils and surrounding inorganic host in detail. </p> <p>Tulej M., Neubeck A., Ivarsson M., Riedo A., Neuland M. B., Meyer S., and Wurz P. (2015) Chemical Composition of Micrometer-Sized Filaments in an Aragonite Host by a Miniature Laser Ablation/Ionization Mass Spectrometer. Astrobiology, 15: 669-682.</p> <p>Westall F., Foucher F., Bost N., Bertrand M., Loizeau D., Vago J. L., Kminek G., Gaboyer F., Campbell K. A., Bréhéret J.-G. and others. (2015) Biosignatures on Mars: What, Where, and How? Implications for the Search for Martian Life. Astrobiology, 15: 998-1029.</p> <p>Wiesendanger R., Wacey D., Tulej M., Neubeck A., Ivarsson M., Grimaudo V., Moreno-García P., Cedeño-López A., Riedo A., Wurz P. and others. (2018) Chemical and Optical Identification of Micrometer-Sized 1.9 Billion-Year-Old Fossils by Combining a Miniature Laser Ablation Ionization Mass Spectrometry System with an Optical Microscope. Astrobiology, 18: 1071-1080.</p> <p>Wurz P., Abplanalp D., Tulej M., Iakovleva M., Fernandes V. A., Chumikov A., and Managadze G. G. (2012) Mass spectrometric analysis in planetary science: Investigation of the surface and the atmosphere. Solar System Research, 46: 408-422.</p> <p> </p>

2020 ◽  
Author(s):  
Marek Tulej ◽  
Rustam Lukmanov ◽  
Andreas Riedo ◽  
Valentine Grimaudo ◽  
Coenraad de Koning ◽  
...  

<p>Searches for the past and present life on the planetary surfaces will be involving multilevel characterisation of the planetary rocks and soils within potentially habitable environments. Some up to three billion years old stromatolites or fossilised bacterial colonies are particularly interesting. They are found on the Earth and thought to be earliest life forms preserved within the terrestrial sedimentary rocks and can be a benchmark for searches of bio-relevant objects on planetary surfaces. By combining the microscope-camera system and mass analyser one can identify micro-fossilised material within the rocks by means of specific morphological details and characteristic chemical composition. We discuss the results of the studies on ancient microfossils obtained by space-born instrumentation, microscope-camera system combined with laser mass spectrometer. Both, the microscope imaging and chemical analyses can be conducted with micrometre spatial resolution. We demonstrate that the morphological record is helpful but not sufficient to identify bio-relevant material. Yet, while combined with elemental and isotope and with help depth profiling method, the compositional analysis can distinguish between abiotic and biological nature of the material. Detection of biosignature in measurements of fossilised materials with a miniature laser ablation ionisation mass analyser.</p> <p> </p> <p>[1] M. Tulej, A. Neubeck, M. Ivarsson, A. Riedo, M.B. Neuland, S. Meyer, P. Wurz, Chemical Composition of Micrometer-Sized Filaments in an Aragonite Host by a Miniature Laser Ablation/Ionization Mass Spectrometer, Astrobiology, 15 (2015) 669-682.</p> <p>[2] A. Neubeck, M. Tulej, M. Ivarsson, C. Broman, A. Riedo, S. McMahon, P. Wurz, S. Bengtson, Mineralogical determination in situ of a highly heterogeneous material using a miniaturized laser ablation mass spectrometer with high spatial resolution, International Journal of Astrobiology, 15 (2016) 133-146.</p> <p>[3] R. Wiesendanger, D. Wacey, M. Tulej, A. Neubeck, M. Ivarsson, V. Grimaudo, P. Moreno-Garcia, A. Cedeno-Lopez, A. Riedo, P. Wurz, Chemical and optical identification of micrometer-sized 1.9 billion-year-old fossils by combining a miniature laser ablation ionization mass spectrometry system with an optical microscope, Astrobiology, 18 (2018) 1071-1080.</p> <p>[4] A. Riedo, A. Bieler, M. Neuland, M. Tulej, P. Wurz, Performance evaluation of a miniature laser ablation time-of-flight mass spectrometer designed for in situ investigations in planetary space research, Journal of Mass Spectrometry, 48 (2013) 1-15.</p> <p>[5] M. Tulej, A. Riedo, M.B. Neuland, S. Meyer, P. Wurz, N. Thomas, V. Grimaudo, P. Moreno-Garcia, P. Broekmann, A. Neubeck, M. Ivarsson, CAMAM: A Miniature Laser Ablation Ionisation Mass Spectrometer and Microscope-Camera System for In Situ Investigation of the Composition and Morphology of Extraterrestrial Materials, Geostand Geoanal Res, 38 (2014) 441-466.</p>


2020 ◽  
Author(s):  
Andreas Riedo ◽  
Valentine Grimaudo ◽  
Joost W. Aerts ◽  
Alena Cedeño López ◽  
Marek Tulej ◽  
...  

<p>In situ identification of life signatures on Solar System bodies other than Earth is extremely challenging and demands for sophisticated and sensitive instrumentation for their detection. Life signatures can be grouped into six different categories, ranging from biomolecules (e.g., lipids and amino acids), to microstructures (such as microfossils) [1]. Sulphur fractionated element isotopes belong to another important category and are of high interest to current astrobiology. In this contribution, we report on a novel measurement protocol, which is dedicated to measure accurately fractionated sulphur isotopes in different Mars analogue materials with an accuracy at the <sup>34</sup>δ level using our miniature and sensitive Laser Ablation Ionisation Mass Spectrometer (LIMS) that was designed for space exploration missions.</p><p>The applied LIMS instrument in this study consists of a miniature reflectron-type time-of-flight mass analyser (160 mm x Ø 60 mm) and a femtosecond laser system (λ = 775 nm, τ ~190 fs) used as ablation and ionization source [2-3]. By means of irradiance studies performed on the Mars analogues, optimal measurement conditions could be elaborated, which allowed to measure sulphur fractionation with an accuracy at the <sup>34</sup>δ level.</p><p>All measurements presented here were conducted on five very different Mars analogues that were collected at different extreme field sites on Earth, including Rio Tinto in Spain and Movile and Sulphur caves in Romania. The analogues differ strongly in their total sulphur weight abundance, which range from ~5 to ~95 %, and in their fractionation degree of sulphur (<sup>34</sup>δ from about +8 to -7). In comparison to the state-of-the-art sulphur isotope measurements the LIMS measurements showed an accuracy of ~1.5 <sup>34</sup>δ. The measurement protocol is simple and sufficiently accurate for in situ application. It will provide valuable information of e.g., geochemical processes occurred on Solar System body surfaces, and will enable the identification of sulphuric-based life in case the fractionation is above fractionation induced by geochemical processes.</p><p>References</p><p>1) E. Hays, H.V. Graham, D.J. Des Marais, E.M. Hausrath, B. Horgan, T.M. McCollom, M. Niki Parenteau, S.L. Potter-McIntyre, A.J. Williams and K.L. Lynch, "Biosignature Preservation and Detection in Mars Analog Environments", Astrobiol., 17, 2017, 363 – 400.</p><p>2) Riedo, M. Neuland, S. Meyer, M. Tulej and P. Wurz, "Coupling of LMS with a fs-laser ablation ion source: elemental and isotope composition measurements", J. Anal. At. Spectrom., 28, 2013, 1256 – 1269.</p><p>3) Tulej, A. Neubeck, M. Ivarsson, A. Riedo, M.B. Neuland, S. Meyer and P. Wurz, "Chemical composition of micrometer-sized filaments in an aragonite host by a miniature laser ablation/ionization mass spectrometer", Astrobiol., 15, 2015, 669 - 682.</p>


Author(s):  
Clara Markert ◽  
Marco Thinius ◽  
Laura Lehmann ◽  
Chris Heintz ◽  
Florian Stappert ◽  
...  

AbstractElectrospray ionization (ESI) generates bare analyte ions from charged droplets, which result from spraying a liquid in a strong electric field. Experimental observations available in the literature suggest that at least a significant fraction of the initially generated droplets remain large, have long lifetimes, and can thus aspirate into the inlet system of an atmospheric pressure ionization mass spectrometer (API-MS). We report on the observation of fragment signatures from charged droplets penetrating deeply the vacuum stages of three commercial mass spectrometer systems with largely different ion source and spray configurations. Charged droplets can pass through the ion source and pressure reduction stages and even into the mass analyzer region. Since droplet signatures were found in all investigated instruments, the incorporation of charged droplets is considered a general phenomenon occurring with common spray conditions in ESI sources.


Author(s):  
Andreas Riedo ◽  
Valentine Grimaudo ◽  
Joost W. Aerts ◽  
Rustam Lukmanov ◽  
Marek Tulej ◽  
...  

The signatures of element isotope fractionation can be used for the indirect identification of extant or extinct life on planetary surfaces or their moons. Element isotope fractionation signatures are very robust against the harsh environmental conditions, such as temperature or irradiation, which typically prevail on solar system bodies. Sulphur is a key element for life as we know it and bacteria exist, such as sulphur reducing bacteria, that can metabolize sulphur resulting in isotope fractionations of up to −70‰ δ34S. Geochemical processes are observed to fractionate up to values of −20‰ δ34S hence, fractionation exceeding that value might be highly indicative for the presence of life. However, the detection of sulphur element isotope fractionation in situ, under the assumption that life has existed or still does exist, is extremely challenging. To date, no instrument developed for space application showed the necessary detection sensitivity or measurement methodology for such an identification. In this contribution, we report a simple measurement protocol for the accurate detection of sulphur fractionation δ34S using our prototype laser ablation ionization mass spectrometer system designed for in situ space exploration missions. The protocol was elaborated based on measurements of five sulphur containing species that were sampled at different Mars analogue field sites, including two cave systems in Romania and the Río Tinto river environment in Spain. Optimising the laser pulse energy of our laser ablation ionization mass spectrometer (LIMS) allowed the identification of a peak-like trend of the 34S/32S ratio, where the maximum, compared to internal standards, allowed to derive isotope fractionation with an estimated δ34S accuracy of ∼2‰. This accuracy is sufficiently precise to differentiate between abiotic and biotic signatures, of which the latter, induced by, e.g., sulphate-reducing microorganism, may fractionate sulphur isotopes by more than −70‰ δ34S. Our miniature LIMS system, including the discussed measurement protocol, is simple and can be applied for life detection on extra-terrestrial surfaces, e.g., Mars or the icy moons like Europa.


Astrobiology ◽  
2015 ◽  
Vol 15 (8) ◽  
pp. 669-682 ◽  
Author(s):  
Marek Tulej ◽  
Anna Neubeck ◽  
Magnus Ivarsson ◽  
Andreas Riedo ◽  
Maike B. Neuland ◽  
...  

2012 ◽  
Vol 84 (2) ◽  
pp. 399-405
Author(s):  
Lucy Takehara ◽  
Farid Chemale Júnior ◽  
Léo A. Hartmann ◽  
Ivo A. Dussin ◽  
Koji Kawashita

Chemical abrasion was carried out on zircons grains of the Temora II standard for U-Pb dating prior to analyses using in situ Laser Ablation-MultiCollector Ion Coupled Plasma Mass Spectrometer (LA-ICPMS) followed by the Isotope Dissolution Thermal Ionization Mass Spectrometer (ID-TIMS) method. The proposed methodology was herein applied in order to reduce primarily the effects of secondary Pb loss, the presence of common lead and/or silicate impurities. Nine Temora II zircon grains were analyzed by the laser ablation method yielding an age of 418.3±4.3 Ma. Zircon grains of a same population were separated for chemical abrasion before dissolution and mass spectrometry analyses. Six fractions of them were separated for isotope dissolution using 235U-205Pb mixed spike after we have checked and assured the laboratory conditions of low blank values for total Pb of less than 2 pg/g. The obtained U-Pb zircon age by the ID-TIMS method was 415.7±1.8 Ma (error 0.43 %) based on four successful determinations. The results are consistent with the published ages for the Temora diorite (Temora I – 416.75±1.3 Ma; Temora II – 416.78±0.33 Ma) and established as 416±0.33 Ma. The technique is thus recommended for high precision U-Pb zircon analyses (error < 1 %), mainly for high resolution stratigraphic studies of Phanerozoic sequences.


2015 ◽  
Vol 87 (4) ◽  
pp. 2037-2041 ◽  
Author(s):  
Valentine Grimaudo ◽  
Pavel Moreno-García ◽  
Andreas Riedo ◽  
Maike B. Neuland ◽  
Marek Tulej ◽  
...  

2005 ◽  
Vol 494 ◽  
pp. 181-186
Author(s):  
M. Veljković ◽  
O. Nešković ◽  
A. Djerić ◽  
S. Veličković ◽  
V. Šipka

A growing number of recent publications on clusters reflect a tremendous interest in these particles. These studies reveal new fundamental physical and chemical aspects of matter. Clusters are called the fifth state of matter: liquid, solid, cluster, gas and plasma. In this work, a carbon cluster was generated by a spark cluster source and detected by single focusing mass spectrometer in situ. We examined the effects of cluster source parameters on the generation of carbon cluster and report our initial results. This method should be useful for studying the mechanism of fullerene formation. In the case when carbon clusters generated in plasma arc are carried by the Ar or H2 gas flow downstream through a vacuum chamber to the ion source of mass spectrometer, we obtained a small binary carbon cluster C28H4 (hydrogenated fullerene). The empty fullerene is tetravalent and strongly binds four hydrogen atoms, which significantly weakens two different sets of bonds and leads to an open-shell electronic structure. Conclusion is that endohedral C28H4 are hypervalent. We have demonstrated how in situ mass spectrometry has led to the rapid development of an important branch of synthetic fullerene chemistry that has yielded many new small fullerenes and related derivatives with novel structures and properties. The impact of mass spectrometry on the synthesis of fullerene derivatives is the subject of this paper. Significantly, a large fraction of products could be condensed on a specially designed collection plate, which allows further spectroscopic characterization of new derivatives.


Sign in / Sign up

Export Citation Format

Share Document