scholarly journals A COMPREHENSIVE REVIEW OF PANSHARPENING ALGORITHMS FOR GÖKTÜRK-2 SATELLITE IMAGES

Author(s):  
S. Kahraman ◽  
A. Ertürk

In this paper, a comprehensive review and performance evaluation of pansharpening algorithms for GÖKTÜRK-2 images is presented. GÖKTÜRK-2 is the first high resolution remote sensing satellite of Turkey which was designed and built in Turkey, by The Ministry of Defence, TUBITAK-UZAY and Turkish Aerospace Industry (TUSAŞ) collectively. GÖKTÜRK-2 was launched at 18th. December 2012 in Jinguan, China and provides 2.5 meter panchromatic (PAN) and 5 meter multispectral (MS) spatial resolution satellite images. In this study, a large number of pansharpening algorithms are implemented and evaluated for performance on multiple GÖKTÜRK-2 satellite images. Quality assessments are conducted both qualitatively through visual results and quantitatively using Root Mean Square Error (RMSE), Correlation Coefficient (CC), Spectral Angle Mapper (SAM), <i>Erreur Relative Globale Adimensionnelle de Synthése</i> (ERGAS), Peak Signal to Noise Ratio (PSNR), Structural Similarity Index (SSIM) and Universal Image Quality Index (UIQI).

2020 ◽  
Vol 24 (1) ◽  
Author(s):  
Srikant Kumar Beura ◽  
Amol Arjun Jawale ◽  
Bishnulatpam Pushpa Devi ◽  
Prabir Saha

Inexact computing is an attractive concept for digital signal processing at the submicron regime. This paper proposes 2-bit inexact adder cell and further escalate to 4-bit, and 8-bit inexact adder and error metrics have been evaluated mathematically for such adder cells. The approximated design has been proposed through the simplification of the K-Maps, which leads to a substantial reduction in the propagation delay as well as energy consumption. The proposed design has been verified through the Cadence Spectre and performance parameters (such as delay, power consumption) have been evaluated through CMOS gpdk45 nm technology. Furthermore, the proposed design has been applied to image de-noising application where the performance of the images like Peak Signal to Noise Ratio (PSNR), Normalized Correlation Coefficient (NCC) and Structural Similarity Index (SSIM) has been analyzed through MATLAB, which offer the substantial improvement from its counterpart.


2021 ◽  
Vol 2070 (1) ◽  
pp. 012139
Author(s):  
V MNSSVKR Gupta ◽  
KVSS Murthy ◽  
R Shiva Shankar

Abstract Image denoising is essential to extract the information contained in an image without errors. A technique of using both wavelets and evolutionary computing tools is proposed to denoise and to improve the image quality. An adaptive thresholding-based wavelet denoising technique in the threshold function is coordinated by novel social group optimization (SGO) and accelerated particle swarm optimization (APSO) is proposed. The simulation oriented experimentation is taken out employing MATLAB and the analysis is carried out using the image property metrics similar to peak signal to noise ratio (PSNR), mean square error (MSE) and other structural similarity index metrics (SSIM).


2020 ◽  
Vol 25 (2) ◽  
pp. 86-97
Author(s):  
Sandy Suryo Prayogo ◽  
Tubagus Maulana Kusuma

DVB merupakan standar transmisi televisi digital yang paling banyak digunakan saat ini. Unsur terpenting dari suatu proses transmisi adalah kualitas gambar dari video yang diterima setelah melalui proses transimisi tersebut. Banyak faktor yang dapat mempengaruhi kualitas dari suatu gambar, salah satunya adalah struktur frame dari video. Pada tulisan ini dilakukan pengujian sensitifitas video MPEG-4 berdasarkan struktur frame pada transmisi DVB-T. Pengujian dilakukan menggunakan simulasi matlab dan simulink. Digunakan juga ffmpeg untuk menyediakan format dan pengaturan video akan disimulasikan. Variabel yang diubah dari video adalah bitrate dan juga group-of-pictures (GOP), sedangkan variabel yang diubah dari transmisi DVB-T adalah signal-to-noise-ratio (SNR) pada kanal AWGN di antara pengirim (Tx) dan penerima (Rx). Hasil yang diperoleh dari percobaan berupa kualitas rata-rata gambar pada video yang diukur menggunakan metode pengukuran structural-similarity-index (SSIM). Dilakukan juga pengukuran terhadap jumlah bit-error-rate BER pada bitstream DVB-T. Percobaan yang dilakukan dapat menunjukkan seberapa besar sensitifitas bitrate dan GOP dari video pada transmisi DVB-T dengan kesimpulan semakin besar bitrate maka akan semakin buruk nilai kualitas gambarnya, dan semakin kecil nilai GOP maka akan semakin baik nilai kualitasnya. Penilitian diharapkan dapat dikembangkan menggunakan deep learning untuk memperoleh frame struktur yang tepat di kondisi-kondisi tertentu dalam proses transmisi televisi digital.


Author(s):  
Indrarini Dyah Irawati ◽  
Sugondo Hadiyoso ◽  
Gelar Budiman ◽  
Asep Mulyana

Compressed sampling in the application of magnetic resonance imaging compression requires high accuracy when reconstructing from a small number of samples. Sparsity in magnetic resonance images is a fundamental requirement in compressed sampling. In this paper, we proposed the lifting wavelet transform sparsity technique by taking wavelet coefficients on the low pass sub-band that contains meaningful information. The application of novel methods useful for compressing data with the highest compression ratio at the sender but still maintaining high accuracy at the receiver. These wavelet coefficient values are arranged to form a sparse vector. We explore the performance of the proposed method by testing at several levels of lifting wavelet transform decomposition, include Levels 2, 3, 4, 5, and 6. The second requirement for compressed sampling is the acquisition technique. The data sampled sparse vectors using a normal distributed random measurement matrix. This matrix is normalized to the average energy of the image pixel block. The last compressed sampling requirement is a reconstruction algorithm. In this study, we analyze three reconstruction algorithms, namely Level 1 magic, iteratively reweighted least squares, and orthogonal matching pursuit, based on structural similarity index measured and peak signal to noise ratio metrics. Experimental results show that magnetic resonance imaging can be reconstructed with higher structural similarity index measured and peak signal to noise ratio using the lifting wavelet transform sparsity technique at a minimum decomposition level of 4. The proposed lifting wavelet transforms and Level 1 magic reconstruction algorithm has the best performance compared to the others at the measurement rate range between 10 to 70. This method also outperforms the techniques in previous studies.


Author(s):  
Jelena Vlaović ◽  
Drago Žagar ◽  
Snježana Rimac-Drlje ◽  
Mario Vranješ

With the development of Video on Demand applications due to the availability of high-speed internet access, adaptive streaming algorithms have been developing and improving. The focus is on improving user’s Quality of Experience (QoE) and taking it into account as one of the parameters for the adaptation algorithm. Users often experience changing network conditions, so the goal is to ensure stable video playback with satisfying QoE level. Although subjective Video Quality Assessment (VQA) methods provide more accurate results regarding user’s QoE, objective VQA methods cost less and are less time-consuming. In this article, nine different objective VQA methods are compared on a large set of video sequences with various spatial and temporal activities. VQA methods used in this analysis are: Peak Signal-to-Noise Ratio (PSNR), Structural Similarity Index (SSIM), MultiScale Structural Similarity Index (MS-SSIM), Video Quality Metric (VQM), Mean Sum of Differences (DELTA), Mean Sum of Absolute Differences (MSAD), Mean Squared Error (MSE), Netflix Video Multimethod Assessment Fusion (Netflix VMAF) and Visual Signal-to-Noise Ratio (VSNR). The video sequences used for testing purposes were encoded according to H.264/AVC with twelve different target coding bitrates, at three different spatial resolutions (resulting in a total of 190 sequences). In addition to objective quality assessment, subjective quality assessment was performed for these sequences. All results acquired by objective VQA methods have been compared with subjective Mean Opinion Score (MOS) results using Pearson Linear Correlation Coefficient (PLCC). Measurement results obtained on a large set of video sequences with different spatial resolutions show that VQA methods like SSIM and VQM correlate better with MOS results compared to PSNR, SSIM, VSNR, DELTA, MSE, VMAF and MSAD. However, the PLCC results for SSIM and VQM are too low (0.7799 and 0.7734, respectively), for the usage of these methods in streaming services instead of subjective testing. These results suggest that more efficient VQA methods should be developed to be used in streaming testing procedures as well as to support the video segmentation process. Furthermore, when comparing results obtained for different spatial resolutions, it can be concluded that the quality of video sequences encoded at lower spatial resolutions in cases of lower target coding bitrate is higher compared to the quality of video sequences encoded at higher spatial resolutions at the same target coding bitrate, particularly when video sequences with higher spatial and temporal information are used.


2020 ◽  
Vol 9 (4) ◽  
pp. 1461-1467
Author(s):  
Indrarini Dyah Irawati ◽  
Sugondo Hadiyoso ◽  
Yuli Sun Hariyani

In this study, we proposed compressive sampling for MRI reconstruction based on sparse representation using multi-wavelet transformation. Comparing the performance of wavelet decomposition level, which are Level 1, Level 2, Level 3, and Level 4. We used gaussian random process to generate measurement matrix. The algorithm used to reconstruct the image is . The experimental results showed that the use of wavelet multi-level can generate higher compression ratio but requires a longer processing time. MRI reconstruction results based on the parameters of the peak signal to noise ratio (PSNR) and structural similarity index measure (SSIM) show that the higher the level of decomposition in wavelets, the value of both decreases.


2020 ◽  
Vol 20 (02) ◽  
pp. 2050008
Author(s):  
S. P. Raja

This paper presents a complete analysis of wavelet-based image compression encoding techniques. The techniques involved in this paper are embedded zerotree wavelet (EZW), set partitioning in hierarchical trees (SPIHT), wavelet difference reduction (WDR), adaptively scanned wavelet difference reduction (ASWDR), set partitioned embedded block coder (SPECK), compression with reversible embedded wavelet (CREW) and spatial orientation tree wavelet (STW). Experiments are done by varying level of the decomposition, bits per pixel and compression ratio. The evaluation is done by taking parameters like peak signal to noise ratio (PSNR), mean square error (MSE), image quality index (IQI) and structural similarity index (SSIM), average difference (AD), normalized cross-correlation (NK), structural content (SC), maximum difference (MD), Laplacian mean squared error (LMSE) and normalized absolute error (NAE).


2018 ◽  
Vol 7 (3.29) ◽  
pp. 269
Author(s):  
Naga Lingamaiah Kurva ◽  
S Varadarajan

This paper presents a new algorithm to reduce the noise from Kalpana Satellite Images using Dual Tree Complex Wavelet Transform technique. Satellite Images are not simple photographs; they are pictorial representation of measured data. Interpretation of noisy raw data leads to wrong estimation of geophysical parameters such as precipitation, cloud information etc., hence there is a need to improve the raw data by reducing the noise for better analysis. The satellite images are normally affected by various noises. This paper mainly concentrates on reducing the Gaussian noise, Poisson noise and Salt & Pepper noise. Finally the performance of the DTCWT wavelet measures in terms of Peak Signal to Noise Ratio and Structural Similarity Index for both noisy & denoised Kalpana images.   


2018 ◽  
Vol 7 (3.12) ◽  
pp. 711
Author(s):  
S Priya ◽  
B Santhi ◽  
J Raja Mohan

In telemedicine, medical data are shared across the world among different specialists for various purposes through an unsecured medium. So there is a need to protect the medical data during transmission. With the help of image watermarking techniques, medical images are protected along with the electronic patient information (EPI). This paper proposes a medical image watermarking, by applying wavelet transform, using an interpolation technique. EPI data is embedded within the transformed medical image to generate a watermarked image. At the extraction side, EPI data are extracted and medical image is reconstructed without any loss. The performance of the proposed method is analyzed using a peak signal to noise ratio (PSNR), mean absolute error (MAE) and structural similarity index (SSIM).   The experimental result shows that the proposed method gives better results.


Sign in / Sign up

Export Citation Format

Share Document