Effect of Harmonics Mitigation on Power Factor Correction for Nonlinear Loads based on Actual Measurement Data

Author(s):  
Jae-Cheon Lee ◽  
Soo-Hwan Cho

This paper presents multifunctional operation capability of three level cascade H bridge inverter for grid connected solar pv application. The solar panel and inverter are modelled for unbalance and nonlinear loads with three control techniques (pq,dq,cpt) and its performance is simulated in the MATLAB environment using SIMULINK and Sim Power System (SPS) toolboxes. The performance of inverter is evaluated for harmonics elimination, power factor correction apart from active and reactive power support to grid and nonlinear load .Performance of three level H bridge inverter is evaluated for both PV mode and STATCOM mode using three control techniques for distribution grid.


Author(s):  
D. E. Egorov ◽  
V. P. Dovgun ◽  
N. P. Boyarskaya ◽  
A. V. Jan ◽  
A. S. Slyusarev

THE PURPOSE. Мutipulse rectifiers are widely used as a nonlinear loads in industrial distribution systems. The advantage of mutipulse rectifiers is low harmonic emission and high power factor. However input currents of mutipulse rectifiers have a wide spectrum including characteristic and noncharacteristic harmonics. This has a negative impact on the power quality. Shunt capacitors are the simplest form of reactive power compensation in industrial power distribution systems. However power systems with nonlinear loads suffer from severe harmonic distortion due to the parallel resonance between capacitors and system inductance. Special compensating devices for reactive power compensation and correction of power system frequency response for resonances damping are necessary. METHODS. In this paper shunt compensating devices for power delivery systems with multipulse nonlinear loads are considered. Proposed devices are composed of 3-5 order parallel connected passive broadband filters. They provide power factor correction, voltage and current harmonics mitigation and resonance modes damping. A general broadband filter design procedure based on frequency and reactive power scaling of normalized filter parameters is developed. RESULTS. Characteristics of different compensating devices configurations using broadband passive filters are discussed. It is shown that broadband filtering devices enable compensation of fundamental frequency reactive power as well as mitigation of voltage harmonic level to values determined by Russian and international standards. Proposed devices have lower fundamental power losses in c omparing with known solutions. CONCLUSION. Proposed analytical design method is applicable to broadband filters of different orders.


2018 ◽  
Vol 2018 ◽  
pp. 1-9 ◽  
Author(s):  
Joaquín Vaquero ◽  
Nimrod Vázquez ◽  
Ivan Soriano ◽  
Jeziel Vázquez

Solar panels are an attractive and growing source of renewable energy in commercial and residential applications. Its use connected to the grid by means of a power converter results in a grid-connected photovoltaic system. In order to optimize this system, it is interesting to integrate several functionalities into the power converter, such as active power filtering and power factor correction. Nonlinear loads connected to the grid generate current harmonics, which deteriorates the mains power quality. Active power filters can compensate these current harmonics. A photovoltaic system with added harmonic compensation and power factor correction capabilities is proposed in this paper. A sliding mode controller is employed to control the power converter, implemented on the CompactRIO digital platform from National Instruments Corporation, allowing user friendly operation and easy tuning. The power system consists of two stages, a DC/DC boost converter and a single-phase inverter, and it is able to inject active power into the grid while compensating the current harmonics generated by nonlinear loads at the point of common coupling. The operation, design, simulation, and experimental results for the proposed system are discussed.


2014 ◽  
Vol 2014 ◽  
pp. 1-10
Author(s):  
Alka Singh

This paper deals with the control of distribution energy resource (DER) connected to a grid connected system feeding nonlinear loads. The DER is controlled to provide power quality improvement capabilities, namely, power factor correction, harmonic reduction, and load balancing. The developed controller is based on modification of synchronous reference theory. It possesses unique features such as filtration and fundamental voltage extraction from the polluted grid voltages to eliminate harmonics and unbalance. Additionally, the control is implemented over the square of DC link voltage. The distributed generation source is realized as a voltage source converter. Both simulation and experimental results prove the effectiveness of control algorithm with nonlinear loads. The control algorithm works well for power factor correction, harmonic reduction, and operation under unbalanced load condition. The dynamics of the system under load change and load unbalancing are well depicted.


Sign in / Sign up

Export Citation Format

Share Document