DEVELOPMENT AND VALIDATION OF AN IMPROVED STABILITY-INDICATING RP-HPLC METHOD FOR THE ESTIMATION OF TROXIPIDE IN BULK AND TABLET DOSAGE FORMS

INDIAN DRUGS ◽  
2015 ◽  
Vol 52 (07) ◽  
pp. 18-22
Author(s):  
D. Gowrisankar ◽  
◽  
N.M Rao

An improved stability-indicating RP-HPLC method was developed for the estimation of troxipide in bulk and tablet dosage forms. Chromatographic separation of troxipide from its degradation products was achieved on Agilent Zorbax SB-CN (150 × 4.6 mm, 3.5 μm) using sodium phosphate buffer (pH was adjusted to 4.0 ±0.05) and acetonitrile in the ratio of 40:60 V/V, at a flow rate of 0.8 mL/min. This system was found to give compact peak for troxipide at 2.1±0.2 min. The detection was monitored at 260 nm. The linear regression data for the calibration plots showed good relationship with r2 = 0.99 ± 0.001. The method was validated for precision, linearity, accuracy and robustness according to International Conference on Harmonization (ICH) guidelines. The percentage RSD was found to be less than two, indicating high degree of accuracy and precision of the proposed RP-HPLC method. The drug was subjected to stress degradation studies under acidic, basic, oxidative and thermal conditions. The degradation studies reveal that purity angle was less than the purity threshold, so the peak was said to be pure. It means that products resulting from stress studies did not interfere with the detection of troxipide and the assay can thus be considered as stability-indicating. Due to its simplicity, rapidness, high precision and accuracy, the proposed HPLC method may be used for determining troxipide in bulk and in pharmaceutical dosage forms.

2020 ◽  
Vol 10 (6) ◽  
pp. 6610-6618

A Simple, selective, accurate, precise, linear, and stability-indicating RP-HPLC method was developed and validated for the estimation of Cinacalcet hydrochloride in bulk and tablet dosage forms. Chromatographic separation was achieved on X-Terra Symmetry C18 (4.6 x 150mm; 5 m) with mobile phase containing Phosphate buffer: Acetonitrile (40:60 v/v) pH adjusted to 3.0 ±0.05 with diluted ortho-phosphoric acid. The flow rate was maintained at 0.9 mL/min. The eluent was monitored at 282 nm. Moreover, the retention time of Cinacalcet was 2.8 minutes. The method was validated for linearity, accuracy, precision, and robustness as per ICH guidelines. The developed method was found linear between 25-150 μg/ml, and the linear regression coefficient was 0.999. The % RSD values are less than 2 % indicating the accuracy and precision of the method. The percentage of recovery was obtained from 98-102%. The system suitability parameters were found to be within the limit. Forced degradation studies were conducted under various conditions. The proposed method is simple, rapid, precise, and accurate. It can be used for the quantitation of Cinacalcet hydrochloride in bulk and commercial pharmaceutical dosage forms.


2015 ◽  
Vol 2015 ◽  
pp. 1-11 ◽  
Author(s):  
V. Ashok Chakravarthy ◽  
B. B. V. Sailaja ◽  
Avvaru Praveen Kumar

The present work was the development of a simple, efficient, and reproducible stability-indicating reverse-phase high performance liquid chromatographic (RP-HPLC) method for simultaneous determination enrofloxacin (EFX) and its degradation products including ethylenediamine impurity, desfluoro impurity, ciprofloxacin impurity, chloro impurity, fluoroquinolonic acid impurity, and decarboxylated impurity in tablet dosage forms. The separation of EFX and its degradation products in tablets was carried out on Kromasil C-18(250×4.6 mm, 5 μm) column using 0.1% (v/v) TEA in 10 mM KH2PO4(pH 2.5) buffer and methanol by linear gradient program. Flow rate was 1.0 mL min−1with a column temperature of 35°C and detection wavelength was carried out at 278 nm and 254 nm. The forced degradation studies were performed on EFX tablets under acidic, basic, oxidation, thermal, humidity, and photolytic conditions. The degraded products were well resolved from the main active drug and also from known impurities within 65 minutes. The method was validated in terms of specificity, linearity, LOD, LOQ, accuracy, precision, and robustness as per ICH guidelines. The results obtained from the validation experiments prove that the developed method is a stability-indicating method and suitable for routine analysis.


2021 ◽  
Vol 7 (1) ◽  
Author(s):  
J. Saroja ◽  
Anantha Lakshmi P.V. ◽  
Y. Rammohan ◽  
D. Divya Reddy

Abstract Background We describe a “stability-indicating liquid chromatography” technique for the estimation of dimethicone (DEC) and dicyclomine hydrochloride (DEH) in the established tablet formulations. Individual quantification of DEH and DEC was reported. But simultaneous quantification of DEH and DEC was lacking. DEH and DEC were analysed on an “XTerra C18 column (250 mm × 4.6 mm, 5 μm)” with the mobile phase solvent run isocratically with 0.1M K2HPO4-acetonitrile (55:45, v/v) on a flow speed of 1.0 mL/min. Results The chromatographic run period for the DEC and DEH assay was 6.0 min with retention times of 2.134 and 2.865 min, respectively. The method was validated for accuracy (99.453 to 100.417% and 99.703 to 100.303% recovery values for DEH and DEC, respectively), precision (RSV value 0.135% for DEC and 0.171% for DEH), linearity (5–15 μg/mL for DEH and 20–60 μg/mL for DEC), selectivity (no hinderance from excipients) and specificity (no hinderance from degradants) recovery. Conclusion The developed stability-indicating liquid chromatography process was well applied to established tablet formulations.


Author(s):  
Swathi P. ◽  
S. Vidyadhara ◽  
R. L. C. Sasidhar ◽  
K. Kalyan Chakravarthi

Objective: The objective and purpose of the analysis have sensibly assessed by selecting of a rapid and sensitive RP-HPLC method for Entecavir in bulk and pharmaceutical dosage form by using the most commonly employed C-18column with UV detection.Methods: In estimation by RP-HPLC method Agilent 1120 compact LC system with variable programmable UV detector and Rheodyne injector with 20 µl fixed loop was used for the chromatographic separation. The mode of operation was isocratic with the components of a solution consisting of methanol: acetonitrile(70:30v/v) and triethanolamine (2-4drops)at the flow rate of 1.2 ml/min and run time was 10 min. Forced degradation studies were conducted to evaluate the stability and specificity of the method along with the validation parameters.Results: Validation parameters of HPLC were found at a detection wavelength of 255 nm. Linearity was observed with the concentration range (Beer’s law range) 20-100µg/ml with R2=0.9991. Robustness with detection wavelengths 253 and 257 nm with a flow rate of 1 ml/min and 1.4 ml/min showed good results. The retention time of the drug was 2.64 min and assay showed 98.1%.Conclusion: The proposed RP-HPLC method was validated as per the ICH Q2B Guidelines, and was found to be applicable for routine quantitative analysis of Entecavir by RP-HPLC using UV detector in pharmaceutical dosage forms. The results of linearity, precision, accuracy and specificity, were proved, that does not exceed certain specified limits. The method provides selective quantification with no interference from other formulation excipients. The proposed method was highly sensitive, reproducible, reliable, robust and specific. Therefore, this method is a simple, rapid analysis may actually be more desirable than a more complicated and time-consuming process. The degradation studies at various stress conditions like thermal and hydrolytic, drug gets degraded at a temperature of 80 °c and refluxing with water at 70 °c for 24hours. 


Sign in / Sign up

Export Citation Format

Share Document