A Proposal and the Effect of Novel Two-Phase PWM Scheme for the Three-Phase Multi-Level Voltage-Fed Converter-Time-Frequency Analyses for the AC-Side Line-to-Line Voltage using Wavelet Transform-

2016 ◽  
Vol 42 (0) ◽  
pp. 31-38 ◽  
Author(s):  
Hayate YATSUKA ◽  
Ryota IMOTO ◽  
Shin-ichi MOTEGI ◽  
Yasuyuki NISHIDA
2011 ◽  
Vol 347-353 ◽  
pp. 2987-2990
Author(s):  
Yuan Yuan Li ◽  
Qi Zhong Liu ◽  
Chao Gang Yu

In electric machinery performance test, tooth harmonic time-frequency characters of first order of three-phase cage asynchronous motor are most important. The MATLAB software is used to make model and simulate the starting characteristic of asynchronous motor in this article, while the stator current signal of starting motor is de noised by wavelet transform. Through decomposition and reconstruction of wavelet transform, the amplitude of fundamental and harmonic wave in de noising stator current can be reduced, and then the tooth harmonic of first order of starting rotor is extracted. Using the excellent time-frequency analyzing characters of wavelet package transform, the tooth harmonic time-frequency curve is fitted.


2014 ◽  
Vol 40 (0) ◽  
pp. 176-181 ◽  
Author(s):  
Ryota IMOTO ◽  
Shin-ichi MOTEGI ◽  
Masakazu MICHIHIRA ◽  
Yasuyuki NISHIDA

2014 ◽  
Vol 472 ◽  
pp. 1042-1046
Author(s):  
Tian Mei Chen ◽  
Xiang Ning Xiao ◽  
Jian Zhang ◽  
Chao Luo

The capability to damp sub-synchronous oscillations of single-phase TCSC, two-phase TCSC, three-phase TCSC is comparatively studied in this paper. SVR (Synchronous Voltage Reversal) is used as the control strategy of these three schemes. And IEEE first benchmark model is taken as the simulation example. Generator power, torques and LVUR (Line Voltage Unbalanced Voltage) are simulated. The results show that all the three schemes can effectively suppress SSO, but compared with single-phase and three-phase TCSC, the convergence rate of generator torques in the two-phase TCSC scheme is slower, thus its damping effect is worse, while single-phase and three-phase nearly has equal damping capacity. After the three-phase fault, the steady value of LVUR under three schemes can all meet the requirements of national standard in China. Through the comparison between these three schemes, it can be concluded that single-phase TCSC is a new structure which has great potential to apply to practical projects, but further theoretical analysis and much more simulation should be done to verify.


1997 ◽  
Vol 117 (3) ◽  
pp. 338-345 ◽  
Author(s):  
Masatake Kawada ◽  
Masakazu Wada ◽  
Zen-Ichiro Kawasaki ◽  
Kenji Matsu-ura ◽  
Makoto Kawasaki

Author(s):  
Guntis Diļevs ◽  
Edgars Jakobsons

The generated power of multipole induction generator with secondary winding on the statorThis paper posses the construction of induction generator, which has the ability to operate at a low rotation speed. This generator can be applied for directly driven turbine without using the gearbox. The generator is multi pole with all of the windings placed on the stator. Rotor is tooth-like and has no windings on it. Primary winding is three phase, secondary winding is two phase.


2020 ◽  
Author(s):  
Ziya Özkan ◽  
Ahmet Masum Hava

In three-phase three-wire (3P3W) voltage-source converter (VSC) systems, utilization of filter inductors with deep saturation characteristics is often advantageous due to the improved size, cost, and efficiency. However, with the use of conventional synchronous frame current control (CSCC) methods, the inductor saturation results in significant dynamic performance loss and poor steady-state current waveform quality. This paper proposes an inverse dynamic model based compensation (IDMBC) method to overcome these performance issues. Accordingly, a review of inductor saturation and core materials is performed, and the motivation on the use of saturable inductors is clarified. Then, two-phase exact modelling of the 3P3W VSC control system is obtained and the drawbacks of CSCC have been demonstrated analytically. Based on the exact modelling, the inverse system dynamic model of the nonlinear system is obtained and employed such that the nonlinear plant is converted to a fictitious linear inductor system for linear current regulators to perform satisfactorily.


1997 ◽  
Vol 35 (7) ◽  
pp. 139-145 ◽  
Author(s):  
Jiann-Yuan Ding ◽  
Shian-Chee Wu

The objective of this study is to quantify the effects of humic acid solution infiltration on the transport of organochlorine pesticides (OCPs) in soil columns using a three-phase transport model. From experimental results, it is found that the dissolved organic carbon enhances the transport of OCPs in the soil columns. In the OCPs-only column, the concentration profiles of OCPs can be simulated well using a two-phase transport model with numerical method or analytical solution. In the OCPs-DOC column, the migrations of aldrin, DDT and its daughter compounds are faster than those in the OCPs-only column. The simulation with the three-phase model is more accurate than that with the two-phase model. In addition, significant decrease of the fluid pore velocities of the OCPs-DOC column was found. When DOC leachate is applied for remediation of soil or groundwater pollution, the decrease of mean pore velocities will be a crucial affecting factor.


Author(s):  
Jingwen Chen ◽  
Hongshe Dang

Background: Traditional thyristor-based three-phase soft starters of induction motor often suffer from high starting current and heavy harmonics. Moreover, both the trigger pulse generation and driving circuit design are usually complicated. Methods: To address these issues, we propose a novel soft starter structure using fully controlled IGBTs in this paper. Compared to approaches of traditional design, this structure only uses twophase as the input, and each phase is controlled by a power module that is composed of one IGBT and four diodes. Results: Consequently, both driving circuit and control design are greatly simplified due to the requirement of fewer controlled power semiconductor switches, which leads to the reduction of the total cost. Conclusion: Both Matlab/Simulink simulation results and experimental results on a prototype demonstrate that the proposed soft starter can achieve better performances than traditional thyristorbased soft starters for Starting Current (RMS) and harmonics.


Sign in / Sign up

Export Citation Format

Share Document