scholarly journals Location of vital structures and available bone for the placement of dental implants in clinically edentulous patients: A cohort study

2021 ◽  
Vol 40 (4) ◽  
pp. 151-157
Author(s):  
Aruna Wimalarathna ◽  
Indika Thilakumara ◽  
Vajira Jayasinghe ◽  
Prasad Amaratunga ◽  
Ruwan Jayasinghe
2011 ◽  
pp. 96-103
Author(s):  
Quang Hai Nguyen ◽  
Toai Nguyen

1. Background: Loss of permanent teeth is very common, affected chewing function, speech and aesthetics; restoration of missing teeth with dental implant has several advantages, but we need thoroughly study the clinical and X ray features at the position at missing teeth, then to select the type of implant and make the best plan for the dental implant patients. 2. Materials and method: Cross-section descriptive study. From January 2009 to November 2010, study with 56 patients with 102 implants of MIS and Megagen systems at the Faculty of Odonto-Stomatology, Hue College of Medicine and Pharmacy and Vietnam-Cuba Hospital in Ha Noi. 3. Results: Distributed equally in male and female, common ages 40 – 59 (55,4%), the majority of missing teeth occurs in the lower jaw (63,8%) and especially, the teeth 36 and 46 (25,4%). The majority of missing teeth due to dental caries, dental pulp and apical diseases (64,7%) of the molar teeth (51,9%); the most position of missing tooth have enough bone for dental implants (87,3%), time of tooth loss and bone status in the position of tooth loss are related to each other (p < 0,01). Diameter and length of implant usually used 4.0 – 6.0 mm (63,7%) and 8.5 – 13.0 mm (83,3%). 4. Conclusion: Clinical and X ray features of edentulous patients has an important role in determining the type of implants and treatment planning of dental implants. Key words: Loss of permanent teeth, X ray and clinical features, Dental implant.


2021 ◽  
Vol 10 (5) ◽  
pp. 1102
Author(s):  
Corina Marilena Cristache ◽  
Mihai Burlibasa ◽  
Ioana Tudor ◽  
Eugenia Eftimie Totu ◽  
Fabrizio Di Francesco ◽  
...  

(1) Background: Prosthetically-driven implant positioning is a prerequisite for long-term successful treatment. Transferring the planned implant position information to the clinical setting could be done using either static or dynamic guided techniques. The 3D model of the bone and surrounding structures is obtained via cone beam computed tomography (CBCT) and the patient’s oral condition can be acquired conventionally and then digitalized using a desktop scanner, partially digital workflow (PDW) or digitally with the aid of an intraoral scanner (FDW). The aim of the present randomized clinical trial (RCT) was to compare the accuracy of flapless dental implants insertion in partially edentulous patients with a static surgical template obtained through PDW and FDW. Patient outcome and time spent from data collection to template manufacturing were also compared. (2) Methods: 66 partially edentulous sites (at 49 patients) were randomly assigned to a PDW or FDW for guided implant insertion. Planned and placed implants position were compared by assessing four deviation parameters: 3D error at the entry point, 3D error at the apex, angular deviation, and vertical deviation at entry point. (3) Results: A total of 111 implants were inserted. No implant loss during osseointegration or mechanical and technical complications occurred during the first-year post-implants loading. The mean error at the entry point was 0.44 mm (FDW) and 0.85 (PDW), p ≤ 0.00; at implant apex, 1.03 (FDW) and 1.48 (PDW), p ≤ 0.00; the mean angular deviation, 2.12° (FDW) and 2.48° (PDW), p = 0.03 and the mean depth deviation, 0.45 mm (FDW) and 0.68 mm (PDW), p ≤ 0.00; (4) Conclusions: Despite the statistically significant differences between the groups, and in the limits of the present study, full digital workflow as well as partially digital workflow are predictable methods for accurate prosthetically driven guided implants insertion.


2021 ◽  
Vol 11 (2) ◽  
pp. 723
Author(s):  
Amani M. Basudan ◽  
Marwa Y. Shaheen ◽  
Abdurahman A. Niazy ◽  
Jeroen J.J.P. van den Beucken ◽  
John A. Jansen ◽  
...  

The installation of dental implants has become a common treatment for edentulous patients. However, concern exists about the influence of osteoporosis on the final implant success. This study evaluated whether an ovariectomy (OVX)-induced osteoporotic condition, induced eight weeks postimplantation in a rat femoral condyle, influences the bone response to already-integrated implants. The implants were inserted in the femoral condyle of 16 female Wistar rats. Eight weeks postimplantation, rats were randomly ovariectomized (OVX) or sham-operated (SHAM). Fourteen weeks later, animals were sacrificed, and implants were used for histological and histomorphometric analyses. A significant reduction in the quantity and quality of trabecular bone around dental implants existed in OVX rats in comparison to the SHAM group. For histomorphometric analysis, the bone area (BA%) showed a significant difference between OVX (34.2 ± 4.3) and SHAM (52.6 ± 12.7) groups (p < 0.05). Bone–implant contact (BIC%) revealed significantly lower values for all implants in OVX (42.5 ± 20.4) versus SHAM (59.0 ± 19.0) rats. Therefore, induction of an osteoporotic condition eight weeks postimplantation in a rat model negatively affects the amount of bone present in close vicinity to bone implants.


2018 ◽  
Vol 44 (5) ◽  
pp. 326-329
Author(s):  
Jacob Horwitz ◽  
Eli E. Machtei ◽  
Shai Frankental ◽  
Eran Gabay ◽  
Yaniv Mayer ◽  
...  

The aim of this prospective cohort observational field trial was to examine 1-year survival and success rates of a recently introduced tapered implant system with switched platform conical abutments and to evaluate patient related outcomes of therapy. Partially edentulous patients aged between 18 and 75 years, with available bone height for dental implants ≥10 mm desiring to restore the missing tooth/teeth with implant supported restoration, were recruited by 7 periodontists in their respective private practices. Dental implants were installed according to standard implant therapy protocol. Three to 6 months postoperatively, after evaluating interim implant success, implants were restored by the referring dentists. Patient, Ramfjord teeth, and implant data, including baseline and 1-year postoperative, were collected. A total of 60 patients were recruited and received 117 implants. Complete 1-year clinical and radiographic data were available for 83 and 65 implants, respectively. Two implants failed during the first year, resulting in a 1-year survival rate of 98.3%. Mean implant probing pocket depth was 2.29 ± 0.84 mm. Mean radiographic bone distance from implant's shoulder at the mesial and distal sites at 1 year was 0.66 ± 0.5 and 0.79 ± 0.64mm, respectively, resulting in a success rate of 95.4%. Patient subjective evaluation of therapy exhibited a median pain experience of 1 and median esthetics, function, and general satisfaction evaluation of 10 on a scale of 1 to 10. The tapered conical connection dental implant system, used in private dental practices, shows good 1-year survival and success rates that are similar to other implant systems on the market.


2019 ◽  
Vol 5 (1) ◽  
Author(s):  
Motaz Osman ◽  
Hassan Ziada ◽  
Ahmed Suliman ◽  
Neamat Hassan Abubakr

Abstract Background An accurate impression is crucial to the long-term success of dental implants. This investigation evaluated the accuracy of the open and closed implant impression techniques in partially edentulous patients who received two adjacent implants. Material and methods Forty patients received Osstem Implants (Osstem Implant System, Seoul, Korea). Two impressions were made for each patient, one using an open tray and a second with a closed tray technique. The horizontal distances between two impression copings were measured and compared to similar measurements on the master casts. Also, under a stereomicroscope (AmScop14370, Myford Road, #150, Irvine, CA 92606 USA) at a 50-fold magnification, the presence or absence of the marginal discrepancies was evaluated. Results There were no statistically significant differences regarding horizontal measurements and in the marginal relationship for the two impression techniques, except between the anterior and posterior regions, for the closed tray technique. There were also no statistically significant differences in the impression accuracy between maxillary and the mandibular arches. In addition, there were no statistically significant differences for the intraoral horizontal distances, compared to similar horizontal measurements on master casts, between the open and closed tray techniques. Conclusions Within the limitations of the present study, there were generally no differences in the impression accuracy between the open and closed tray techniques in partially edentulous patients with two adjacent implants.


2021 ◽  
Vol 2021 ◽  
pp. 1-9
Author(s):  
Jan Kowar ◽  
Victoria Stenport ◽  
Mats Nilsson ◽  
Torsten Jemt

Objectives. The purpose of this study was to investigate if edentulism is associated with all-cause mortality. The aims were to analyze the association between age, socioeconomic factors, and mortality in edentulous patients treated with either removable dentures or implant-supported prostheses. Methods. All patients who became edentulous according to the Swedish Social Insurance Agency (SSIA) between 2009 and 2013 (N  = 8463) were analyzed regarding prosthetic treatment, age, gender, and socioeconomic status. The patients were divided into two groups, depending on whether they were treated with dental implants (implant group; IG) or with conventional removable dentures (denture group; DG). Data on mortality for all included individuals were obtained from the Swedish National Cause of Death Register and compared to a reference population. Cumulative survival rates were calculated, and a multivariable regression analysis for the included variables was performed. Results. Between 2009 and 2018, 2192 of the patients (25.9%) were treated with implant-supported dental prostheses (IG) and 6271 patients (74.1%) were treated with removable dentures without support of dental implants (DG). Altogether 2526 patients (30%) died until December 31, 2019, and the overall mortality was significantly higher for the DG compared to the IG during follow-up ( p < 0.001 ). Younger edentulous patients (≤59 years) presented a higher mortality than the reference population, while implant patients over 79 years of age demonstrated a lower mortality. The final results from the multivariable logistic analysis showed that lower equalized disposable income (EDI) and the choice of conventional removable dentures are the most important factors for increased patient mortality ( p < 0.001 ). Conclusions. Edentulous patients have an overall higher mortality compared to a reference population. Low socioeconomic status increases all-cause mortality. Individuals treated with dental implants show statistically significant lower 10-year mortality compared to patients treated with conventional removable dentures, regardless of socioeconomic status.


2021 ◽  
Vol 108 (Supplement_6) ◽  
Author(s):  
P Lugaric ◽  
C Frezzini ◽  
A Patterson

Abstract Aim To determine the success rates of dental implants in complex patients treated in the Oral and Maxillofacial Surgery Department at Rotherham General Hospital (RGH). Method All patients who received dental implants in the period January 2010 – March 2017 at RGH were included in the audit. Standards 90% local standard Results 68 dental implants were placed in 22 patients: 15 patients head and neck reconstruction, 5 atrophic edentulous patients, 2 trauma. Conclusions Survival rates for dental implants in the literature is variable ranging from 91 -96% in native bone and mucosa and 46 - 98% in irradiated tissue.


Sign in / Sign up

Export Citation Format

Share Document