scholarly journals Multiple perineural cysts in the cervical, thoracic, and lumbar vertebrae of a mature individual

2021 ◽  
Vol 32 (1) ◽  
pp. 262-266
Author(s):  
Mehmet Ali Tokgöz
2014 ◽  
Author(s):  
Krzysztof Chmielowiec ◽  
Marcin Tatara ◽  
Witold Krupski ◽  
Iwona Luszczewska-Sierakowska ◽  
Marek Bienko ◽  
...  

2019 ◽  
Vol 1 (4) ◽  
Author(s):  
Yustinus Robby Budiman Gondowardojo ◽  
Tjokorda Gde Bagus Mahadewa

The lumbar vertebrae are the most common site for fracture incident because of its high mobility. The spinal cord injury usually happened as a result of a direct traumatic blow to the spine causing fractured and compressed spinal cord. A 38-year-old man presented with lumbar spine’s compression fracture at L2 level. In this patient, decompression laminectomy, stabilization, and fusion were done by posterior approach. The operation was successful, according to the X-Ray and patient’s early mobilization. Pneumothorax of the right lung and pleural effusion of the left lung occurred in this patient, so consultation was made to a cardiothoracic surgeon. Chest tube and WSD insertion were performed to treat the comorbidities. Although the patient had multiple trauma that threat a patient’s life, the management was done quickly, so the problems could be solved thus saving the patient’s life. After two months follow up, the patient could already walk and do daily activities independently.


Author(s):  
Sebastian Zensen ◽  
Sumitha Selvaretnam ◽  
Marcel Opitz ◽  
Denise Bos ◽  
Johannes Haubold ◽  
...  

Abstract Purpose Apart from the commonly applied manual needle biopsy, CT-guided percutaneous biopsies of bone lesions can be performed with battery-powered drill biopsy systems. Due to assumably different radiation doses and procedural durations, the aim of this study is to examine radiation exposure and establish local diagnostic reference levels (DRLs) of CT-guided bone biopsies of different anatomical regions. Methods In this retrospective study, dose data of 187 patients who underwent CT-guided bone biopsy with a manual or powered drill biopsy system performed at one of three different multi-slice CT were analyzed. Between January 2012 and November 2019, a total of 27 femur (A), 74 ilium (B), 27 sacrum (C), 28 thoracic vertebrae (D) and 31 lumbar vertebrae (E) biopsies were included. Radiation exposure was reported for volume-weighted CT dose index (CTDIvol) and dose–length product (DLP). Results CTDIvol and DLP of manual versus powered drill biopsy were (median, IQR): A: 56.9(41.4–128.5)/66.7(37.6–76.2)mGy, 410(203–683)/303(128–403)mGy·cm, B: 83.5(62.1–128.5)/59.4(46.2–79.8)mGy, 489(322–472)/400(329–695)mGy·cm, C: 97.5(71.6–149.2)/63.1(49.1–83.7)mGy, 627(496–740)/404(316–515)mGy·cm, D: 67.0(40.3–86.6)/39.7(29.9–89.0)mGy, 392(267–596)/207(166–402)mGy·cm and E: 100.1(66.5–162.6)/62.5(48.0–90.0)mGy, 521(385–619)/315(240–452)mGy·cm. Radiation exposure with powered drill was significantly lower for ilium and sacrum, while procedural duration was not increased for any anatomical location. Local DRLs could be depicted as follows (CTDIvol/DLP): A: 91 mGy/522 mGy·cm, B: 90 mGy/530 mGy·cm, C: 116 mGy/740 mGy·cm, D: 87 mGy/578 mGy·cm and E: 115 mGy/546 mGy·cm. The diagnostic yield was 82.4% for manual and 89.4% for powered drill biopsies. Conclusion Use of powered drill bone biopsy systems for CT-guided percutaneous bone biopsies can significantly reduce the radiation burden compared to manual biopsy for specific anatomical locations such as ilium and sacrum and does not increase radiation dose or procedural duration for any of the investigated locations. Level of Evidence Level 3.


2021 ◽  
pp. 296-302
Author(s):  
Ryosuke Hirota ◽  
Makoto Emori ◽  
Yoshinori Terashima ◽  
Kousuke Iba ◽  
Noriyuki Iesato ◽  
...  

We present the case of a 15-year-old girl. Two months after becoming aware of pain, she was diagnosed with a sacral tumor and referred to our department. She was diagnosed with a sacral Ewing’s sarcoma; after chemotherapy, it was determined that the tumor could be resected, so surgical treatment was performed. The sacrum and ilium were partially resected at the lower end of S1, and the lumbar vertebrae and pelvis were fixed with a pedicle screw and two iliac screws on each side of L3, and the sacral resection was reconstructed with a tibial strut allograft. No tumor recurrence or metastasis has been observed 1 year postoperatively. She developed bladder and rectal dysfunction, but she remained independent in activities of daily living and her daily life was not limited. The bone fusion in the reconstructed area confirmed the lack of instrumentation looseness. Surgical treatment for sacral Ewing’s sarcoma was performed to cure the patient. We believe that the tibial allograft contributed to the patient’s ability to walk on her own due to its high mechanical stability. Postoperative bone healing was observed with the same material, suggesting that the tibial allograft is useful for similar procedures.


2009 ◽  
Vol 36 (3) ◽  
pp. 609-613 ◽  
Author(s):  
RUKMINI M. KONATALAPALLI ◽  
PAUL J. DEMARCO ◽  
JAMES S. JELINEK ◽  
MARK MURPHEY ◽  
MICHAEL GIBSON ◽  
...  

Objective.Gout typically affects the peripheral joints of the appendicular skeleton and rarely involves the axial joints. The literature on axial gout is limited to case reports and case series. This preliminary study was conducted to identify the frequency and characteristics of axial gout.Methods.Six hundred thirty medical records with ICD codes 274.0, 274.82, and 274.9 for peripheral gout were reviewed. Ninety-two patients had clinical or crystal-proven gout, of which 64 had prior computed tomography (CT) images of the spine performed for various medical reasons. These CT images were reviewed for features of axial gout, which include vertebral erosions mainly at the discovertebral junction and the facet joints, deposits of tophi, and erosions in the vertebral body, epidural space, ligamentum flavum and pars interarticularis.Results.Nine of the 64 patients had radiographic changes suggestive of axial gout. Lumbar vertebrae were most commonly involved, with facet joint erosions being the most common finding. Isolated involvement of the sacroiliac joints was seen in 2 patients. Axial gout had been diagnosed clinically in only one patient.Conclusion.Radiologic changes of axial gout were more common than recognized clinically, with a frequency of 14%. Since not all patients had CT images, it is possible that the frequency of axial involvement was even greater. A prospective study is needed to further define this process.


1981 ◽  
Vol 33 (3) ◽  
pp. 319-324 ◽  
Author(s):  
A. J. Kempster ◽  
J. P. Chadwick ◽  
D. W. Jones ◽  
A. Cuthbertson

ABSTRACTThe Hennessy and Chong Fat Depth Indicator and the Ulster Probe automatic recording instruments developed for measuring fat thickness were tested against the optical probe for use in pig carcass classification and grading.Fat thickness measurements were taken using each probe 60 mm from the dorsal mid-line over the m. longissimus at the positions of the 3rd/4th lumbar vertebrae, 3rd/4th last ribs and last rib on a total of 110 hot carcasses covering the range of market weights in Great Britain. The standard deviation of carcass lean proportion at equal carcass weight was 35·4 g/kg.The instruments differed little in the precision of carcass lean proportion prediction: residual standard deviation (g/kg) for the multiple regression with carcass weight and the best individual fat measurement for each probe were: last rib optical probe, 22·1; last rib Ulster Probe, 22·7; and 3rd/4th last rib Fat Depth Indicator, 21/6. Residual standard deviation (g/kg) for carcass lean proportion prediction from carcass weight and all three fat measurements in multiple regression were 21·3 optical probe, 21·3 Ulster Probe and 201 Fat Depth Indicator.Similar mean fat measurements were obtained from the optical probe and Fat Depth Indicator, and for these instruments, but to a lesser extent for the Ulster Probe, the regression relationships with each other and with fat thickness measurements taken on the cut surface of the cold carcass were also similar.The differences recorded in precision are unlikely to be sufficiently important to influence the choice of one probe rather than another.


Sign in / Sign up

Export Citation Format

Share Document