scholarly journals Effects of Control Methods of Outdoor Air Cooling System on Energy Consumption in Building

2015 ◽  
Vol 16 (6) ◽  
pp. 4253-4259 ◽  
Author(s):  
Jin-Won Hwang ◽  
Byung-Cheon Ahn
Energies ◽  
2020 ◽  
Vol 13 (21) ◽  
pp. 5719
Author(s):  
JiHyun Hwang ◽  
Taewon Lee

The recent expansion of the internet network and rapid advancements in information and communication technology are expected to lead to a significant increase in power consumption and the number of data centers. However, these data centers consume a considerable amount of electric power all year round, regardless of working days or holidays; thus, energy saving at these facilities has become essential. A disproportionate level of power consumption is concentrated in computer rooms because air conditioners in these rooms are required to operate throughout the year to maintain a constant indoor environment for stable operation of computer equipment with high-heat release densities. Considerable energy-saving potential is expected in such computer rooms, which consume high levels of energy, if an outdoor air-cooling system and air conditioners are installed. These systems can reduce the indoor space temperature by introducing a relatively low outdoor air temperature. Therefore, we studied the energy-saving effect of introducing an outdoor air-cooling system in a computer room with a disorganized arrangement of servers and an inadequate air conditioning system in a research complex in Korea. The findings of this study confirmed that annual energy savings of up to approximately 40% can be achieved.


2018 ◽  
Vol 32 ◽  
pp. 01017
Author(s):  
Octavian G. Pop ◽  
Lucian Fechete Tutunaru ◽  
Florin Bode ◽  
Mugur C. Balan

Solid-liquid phase change is used to accumulate and release cold in latent heat thermal energy storage (LHTES) in order to reduce energy consumption of air cooling system in buildings. The storing capacity of the LHTES depends greatly on the exterior air temperatures during the summer nights. One approach in intensifying heat transfer is by increasing the air’s velocity. A LHTES was designed to be integrated in the air cooling system of a building located in Bucharest, during the month of July. This study presents a numerical investigation concerning the impact of air inlet temperatures and air velocity on the formation of solid PCM, on the cold storing capacity and energy consumption of the LHTES. The peak amount of accumulated cold is reached at different air velocities depending on air inlet temperature. For inlet temperatures of 14°C and 15°C, an increase of air velocity above 50% will not lead to higher amounts of cold being stored. For Bucharest during the hottest night of the year, a 100 % increase in air velocity will result in 5.02% more cold being stored, at an increase in electrical energy consumption of 25.30%, when compared to the reference values.


2019 ◽  
Vol 23 (4) ◽  
pp. 2421-2428
Author(s):  
Jing Ma ◽  
Yin Liu ◽  
Ren-Bo Guan

A fresh air-cooling plan is proposed to deal with high energy consumption in a data center and continuous improvement of temperature resistance performance in an IT equipment. The modularized data center, which is designed to adopt outdoor fresh air-cooling method for reducing temperature, can greatly reduce the energy consumption in data center. Numerical approach to study on the distribution of flow field, temperature field and velocity field is given using the CFD software. The results show that the flow field distribution is uniform, and the temperature distribution meets the requirements of the data center system. The numerical results can be used for optimization of the modularized computer room.


2021 ◽  
Vol 09 (03) ◽  
pp. E482-E486
Author(s):  
Stanislas Chaussade ◽  
Einas Abou Ali ◽  
Rachel Hallit ◽  
Arthur Belle ◽  
Maximilien Barret ◽  
...  

Abstract Background and study aims The role that air circulation through a gastrointestinal endoscopy system plays in airborne transmission of microorganisms has never been investigated. The aim of this study was to explore the potential risk of transmission and potential improvements in the system. Methods We investigated and described air circulation into gastrointestinal endoscopes from Fujifilm, Olympus, and Pentax. Results The light source box contains a lamp, either Xenon or LED. The temperature of the light is high and is regulated by a forced-air cooling system to maintain a stable temperature in the middle of the box. The air used by the forced-air cooling system is sucked from the closed environment of the patient through an aeration port, located close to the light source and evacuated out of the box by one or two ventilators. No filter exists to avoid dispersion of particles outside the processor box. The light source box also contains an insufflation air pump. The air is sucked from the light source box through one or two holes in the air pump and pushed from the air pump into the air pipe of the endoscope through a plastic tube. Because the air pump does not have a dedicated HEPA filter, transmission of microorganisms cannot be excluded. Conclusions Changes are necessary to prevent airborne transmission. Exclusive use of an external CO2 pump and wrapping the endoscope platform with a plastic film will limit scatter of microorganisms. In the era of pandemic virus with airborne transmission, improvements in gastrointestinal ventilation systems are necessary to avoid contamination of patients and health care workers.


2015 ◽  
Vol 76 ◽  
pp. 449-461 ◽  
Author(s):  
Mehdi A. Ehyaei ◽  
Mojtaba Tahani ◽  
Pouria Ahmadi ◽  
Mohammad Esfandiari

Author(s):  
A. Al Bassam ◽  
Y. M. Al Said

This paper summarizes the experiences with the first gas turbine inlet air cooling project in Saudi Arabia. It will cover the feasibility study, cooling system options, overview, system equipment description, process flow diagram, construction, commissioning, start-up and performance of the project which is currently under commissioning and initial start up at Qassim Central Power Plant (QCPP) owned by Saudi Electric Company (S.E.C.) Central Region Branch.