scholarly journals Energy-Efficient Retrofit Measures to Achieve Nearly Zero Energy Buildings

2022 ◽  
Author(s):  
Nimish Biloria ◽  
Nastaran Abdollahzadeh

Considering the 2021 IPCC report that justly attributes our deteriorating climatic condition to human doing, the need to develop nearly zero energy building (nZEB) practices is gaining urgency. However, rather than the typical focus on developing greenfield net-zero initiatives, retrofitting underperforming buildings could create significant scale climate positive impacts faster. The chapter accordingly discusses energy-efficient retrofitting methods under three categorical sectors—visual comfort (daylight-based zoning, shadings); thermal comfort and ventilation (solar radiation-based zoning, central atrium plus interior openings, insulation, and window replacement); energy consumption (efficient lighting system, and controllers, material and HVAC system optimization, PV panels as the renewable energy source). This chapter further substantiates these theoretical underpinnings with an implemented design scheme—an educational building within a cold semiarid climatic condition—to showcase the on-ground impact of these retrofitting strategies in reducing the energy used for heating and cooling and lighting purposes.

Author(s):  
Jordan Thompson ◽  
Moncef Krarti

Abstract In this paper, a resiliency analysis is conducted to assess the energy, economic, and outage survivability benefits of efficient and Net-Zero Energy (NZE) communities. The analysis addresses the design of an energy-efficient and NZE community using Phoenix, Arizona as the primary location. The loads from the baseline, energy-efficient , and NZE single-family homes modeled in BEopt are used to determine load profiles for various residential community types. The photovoltaic (PV) and battery storage system sizes necessary for the community to survive a 72-hour power outage are determined using REopt. The economic analysis indicates that it is 43% more cost-effective to install a shared PV plus storage system than to install individual PV plus storage systems in an energy-efficient community. It is found that only a 4% difference in net present cost exists between a PV plus storage system sized for a 24-hour outage and a 144-hour outage. In the event of a community-wide lockdown, the survivability of the energy-efficient community is only 6 hours during a time where plug loads are increased by 50% due to added office electronics. A climate sensitivity analysis is conducted for efficient communities in Naperville, Illinois and Augusta, Maine. The analysis suggests that for a 72-hour power outage starting on the peak demand day and time of the year, the cost of resiliency is higher in climates with more heating and cooling needs as HVAC is consistently the largest load in a residential building.


2016 ◽  
Vol 19 (3) ◽  
pp. 130 ◽  
Author(s):  
Jean Castaing-Lasvignottes ◽  
Mathieu David ◽  
Sidiki Simpore ◽  
Olivier Marc ◽  
François Garde

Author(s):  
Hugo Hens

Since the 1990s, the successive EU directives and related national or regional legislations require new construction and retrofits to be as much as possible energy-efficient. Several measures that should stepwise minimize the primary energy use for heating and cooling have become mandated as requirement. However, in reality, related predicted savings are not seen in practice. Two effects are responsible for that. The first one refers to dweller habits, which are more energy-conserving than the calculation tools presume. In fact, while in non-energy-efficient ones, habits on average result in up to a 50% lower end energy use for heating than predicted. That percentage drops to zero or it even turns negative in extremely energy-efficient residences. The second effect refers to problems with low-voltage distribution grids not designed to transport the peaks in electricity whensunny in summer. Through that, a part of converters has to be uncoupled now and then, which means less renewable electricity. This is illustrated by examples that in theory should be net-zero buildings due to the measures applied and the presence of enough photovoltaic cells (PV) on each roof. We can conclude that mandating extreme energy efficiency far beyond the present total optimum value for residential buildings looks questionable as a policy. However, despite that, governments and administrations still seem to require even more extreme measurements regarding energy efficiency.


2020 ◽  
Author(s):  
Lazaros Aresti ◽  
Paul Christodoulides ◽  
Georgios A. Florides

<p>Shallow Geothermal Energy, a Renewable Energy Source, finds application through Ground Source Heat Pumps (GSHPs) for space heating/cooling via tubes directed into the ground. There are two main categories of Ground Heat Exchanger (GHE) types: the horizontal and the vertical types. Ground Heat Exchangers (GHEs) of various configurations, extract or reject heat into the ground. Even though GSHP have higher performance in comparison to the Air Source Heat Pumps (ASHPs), the systems high initial costs and long payback period have made it unattractive as an investment. GSHP systems can also be utilized in the buildings foundation in the form of Thermo-Active Structure (TAS) systems or Energy Geo-Structures (EGS), with applications such as energy piles, barrette piles, diaphragm walls, shallow foundations, retaining walls, embankments, and tunnel linings. Energy piles are reinforced concrete foundations with geothermal pipes, whereby the buildings foundations are utilized to provide space heating and cooling. Apart from energy piles, another EGS system can be achieved by the incorporation of the building’s foundation bed as a GHE. Foundation piles are not required in all constructions, but a building’s foundation bed is mandatory. This configuration is still based on the principles of the energy pile.</p><p>Energy piles have yet to be applied in Cyprus and, thus, a preliminary assessment considered and investigated before application would be useful. The potential of the GSHP systems by utilizing the building’s foundation through energy piles is considered here, for a moderate climate such as Cyprus, towards a Zero Energy Building. Typical foundation piles geometry in Cyprus consists of a 10m depth, a 0.4m diameter and reinforced concrete as a grout material, which is used at the foundation bed of the building. A typical dwelling in Cyprus is selected to be numerically modelled in this study. It is a three-bedroom, two-storey house with a 190m<sup>2</sup> total floor area, matching the thermal characteristics of a Zero Energy Building (i.e., U-values of 0.4W/m<sup>2</sup>/K on all walls and ceiling and 2.25 W/m<sup>2</sup>/K on all doors and windows, respectively). A full-scale model is developed in COMSOL Multiphysics software, to examine the energy rejected or absorbed into the ground by taking the heating and cooling loads of the typical dwelling in Cyprus. The convection-diffusion equation for heat transfer is used with the three-dimensional conservation of heat transfer for an incompressible fluid on all domains except the pipes, where a simplified equation is used. Different months in winter and summer are accounted for the simulations and the fluid-in – fluid-out temperature difference is presented. Finally, an economic evaluation of the systems examined above is presented, in order to check its viability. It is concluded that utilizing the dwelling’s foundations can be a better investment than using GHEs in boreholes.</p>


Sign in / Sign up

Export Citation Format

Share Document